0 of 0
Data and communication cable
Electrical cables and wiring. Alarm cable; Cable; Cat cable; cat5; cat5e; cat6; cat7; Control cable; Data and communication cable; Data and communication cable (copper); Data and communication cable (metallic); Data cable; Ethernet cable; F/FTP; F/UTP; Outdoor cable; Patch cable; Railway signalling cable; S/FTP; S/UTP; Security cable; SF/FTP; SF/UTP; Shipboard communication cable; Signal-/telecommunications cable; U/FTP; U/UTP
Code:
EC003249
Version:
Group:
Electrical cables and wiring
EG000001Release:
DYNAMIC, ETIM-10.0
01 |
Cable typeEF000081 - Alphanumeric | ||
02 |
DuplexEF023003 - Logical | ||
03 |
Conductor materialEF001622 - Alphanumeric | ||
04 |
Conductor surfaceEF010804 - Alphanumeric | ||
05 |
Conductor Diameter (mm)EF001621 - Numeric | ||
06 |
Nominal cross sectional area of conductor (mm²)EF000060 - Numeric | ||
07 |
AWG sizeEF011789 - Alphanumeric | ||
08 |
Conductor categoryEF001632 - Alphanumeric | ||
09 |
Number of coresEF001792 - Numeric | ||
10 |
Number of stranding elementsEF001688 - Numeric | ||
11 |
Stranding elementEF001617 - Alphanumeric | ||
12 |
Core insulation materialEF000061 - Alphanumeric | ||
13 |
Specification core insulationEF011805 - Alphanumeric | ||
14 |
Core identification according to HD 308 S2EF013766 - Logical | ||
15 |
Core identificationEF000067 - Alphanumeric | ||
16 |
Individual screen typeEF001623 - Alphanumeric | ||
17 |
StrandingEF003802 - Alphanumeric | ||
18 |
Overall screen typeEF001624 - Alphanumeric | ||
19 |
Longitudinal water blocking cableEF011011 - Logical | ||
20 |
Radial water blocking cableEF011012 - Logical | ||
21 |
Suitable for underground installationEF003689 - Logical | ||
22 |
Approved type of underground installationEF015176 - Alphanumeric | ||
23 |
Protective sheathEF001691 - Alphanumeric | ||
24 |
Sheath materialEF001625 - Alphanumeric | ||
25 |
Sheath material specificationEF011806 - Alphanumeric | ||
26 |
Sheath colourEF001618 - Alphanumeric | ||
27 |
Number of sheath layersEF016997 - Numeric | ||
28 |
Armouring/reinforcementEF001683 - Alphanumeric | ||
29 |
Material armouringEF013440 - Alphanumeric | ||
30 |
Cable geometryEF013532 - Alphanumeric | ||
31 |
Flame retardant according to IEC 60332-1-2EF016492 - Logical | ||
32 |
Flame retardant according to IEC 60332-3-21 (Cat A F/R)EF016493 - Logical | ||
33 |
Flame retardant according to IEC 60332-3-22 (Cat A)EF016494 - Logical | ||
34 |
Flame retardant according to IEC 60332-3-23 (Cat B)EF016495 - Logical | ||
35 |
Flame retardant according to IEC 60332-3-24 (Cat C)EF016496 - Logical | ||
36 |
Flame retardant according to IEC 60332-3-25 (Cat D)EF016497 - Logical | ||
37 |
Low smoke according to IEC 61034-2EF003799 - Logical | ||
38 |
Halogen free according to IEC 60754-1EF016498 - Logical | ||
39 |
Halogen free according to IEC 60754-2EF003792 - Logical | ||
40 |
Halogen free according to IEC 60754-3EF016500 - Logical | ||
41 |
Reaction-to-fire according to EN 13501-6: ClassEF011577 - Alphanumeric | ||
42 |
Reaction-to-fire according to EN 13501-6: Smoke productionEF011578 - Alphanumeric | ||
43 |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particlesEF011579 - Alphanumeric | ||
44 |
Reaction-to-fire according to EN 13501-6: AcidityEF011580 - Alphanumeric | ||
45 |
Circuit integrity according to IEC 60331-23EF016619 - Logical | ||
46 |
Oil resistant according to IEC 60811-404EF009770 - Logical | ||
47 |
Outer diameter approx. (mm)EF003921 - Numeric | ||
48 |
Min. permitted bending radius, moving application with forced guidance (mm)EF011801 - Numeric | ||
49 |
Min. permitted bending radius, moving application/free movement (mm)EF011802 - Numeric | ||
50 |
Min. permitted bending radius, stationary application/permanent installation (mm)EF011803 - Numeric | ||
51 |
Permitted cable outer temperature during assembling/handling (°C)EF001685 - Range | ||
52 |
Permitted cable outer temperature after assembling without vibration (°C)EF001686 - Range | ||
53 |
CategoryEF001619 - Alphanumeric | ||
54 |
NVP value (%)EF008387 - Numeric | ||
55 |
Certified for shipboard applicationEF013772 - Logical | ||
56 |
Segregation class according to EN 50174-2EF013986 - Alphanumeric | ||
57 |
Suitable for use as telephone cableEF013768 - Logical | ||
58 |
Suitable for use as computer data cableEF013769 - Logical | ||
59 |
Suitable for use as signalling cableEF013770 - Logical | ||
60 |
Suitable for use as security alarm cableEF017089 - Logical | ||
61 |
Drain wireEF001029 - Logical | ||
62 |
With rip cordEF017088 - Logical | ||
63 |
Cable width approx. (mm)EF003796 - Numeric | ||
64 |
Cable height approx. (mm)EF003797 - Numeric | ||
65 |
Weight (kg/km)EF000167 - Numeric | ||
66 |
Characteristic impedance (Ohm)EF001628 - Numeric | ||
67 |
Max. tensile strength during installation (kN)EF013801 - Numeric | ||
68 |
Nominal voltage U (V)EF001615 - Numeric | ||
69 |
Rodent resistantEF007960 - Logical | ||
70 |
Circuit integrity according to DIN 4102-12EFDE0051 - Alphanumeric | ||
71 |
Compatible with Grade2TV according to XP-C 90-483EFFR0001 - Logical | ||
72 |
Compatible with Grade3TV according to XP-C 90-483EFFR0002 - Logical | ||
73 |
Cable type in accordance with BS 4737-3.30EFUK0022 - Alphanumeric | ||
74 |
Rip cord colour in accordance with BS 4737-3.30EFUK0023 - Alphanumeric | ||
75 |
Compliant with BT (British Telecom) specificationEFUK0024 - Alphanumeric |
Alarm cable
Cable
Cat cable
cat5
cat5e
cat6
cat7
Control cable
Data and communication cable
Data and communication cable (copper)
Data and communication cable (metallic)
Data cable
Ethernet cable
F/FTP
F/UTP
Outdoor cable
Patch cable
Railway signalling cable
S/FTP
S/UTP
Security cable
SF/FTP
SF/UTP
Shipboard communication cable
Signal-/telecommunications cable
U/FTP
U/UTP