0 of 0

Power cable >= 1 kV, for permanent installation

Code

EC003251

Version

Group

Cables and wires (unassembled) (EG000001)

Release

ETIM-8.0
Features

01

Conductor material

EF001622 - Alphanumeric

02

Conductor surface

EF010804 - Alphanumeric

03

Nominal cross section conductor (mm²)

EF000060 - Numeric

04

AWG size

EF011789 - Alphanumeric

05

Nominal cross section conductor (AWG) (kcmil)

EF011790 - Numeric

06

Conductor category

EF001632 - Alphanumeric

07

Conductor resistance at 20 °C (Ohm/km)

EF013551 - Numeric

08

Shape of conductor

EF001620 - Alphanumeric

09

Number of cores

EF001792 - Numeric

10

Material core insulation

EF000061 - Alphanumeric

11

Specification core insulation

EF011805 - Alphanumeric

12

Core identification according to HD 308 S2

EF013766 - Logical

13

Core identification

EF000067 - Alphanumeric

14

Laminated sheath

EF001637 - Logical

15

Fibre optic elements

EF001638 - Logical

16

With protective conductor

EF007468 - Logical

17

Inner semi-conducting layer

EF001700 - Logical

18

Outer semi-conducting layer

EF001701 - Logical

19

Screen

EF001791 - Logical

20

Drain wire

EF001029 - Logical

21

Lead sheath

EF001027 - Logical

22

Number of pilot/reduced conductors

EF001697 - Numeric

23

Nominal cross section pilot/reduced conductor (mm²)

EF003805 - Numeric

24

Concentric conductor

EF003795 - Alphanumeric

25

Nominal cross section concentric conductor (mm²)

EF001800 - Numeric

26

Armouring

EF001024 - Logical

27

Material outer sheath

EF001625 - Alphanumeric

28

Specification material outer sheath

EF011806 - Alphanumeric

29

Colour outer sheath

EF001618 - Alphanumeric

30

Cable geometry

EF013532 - Alphanumeric

31

Conductive coating

EF008389 - Logical

32

Longitudinal water blocking conductors

EF001795 - Logical

33

Longitudinal water blocking screen

EF001704 - Logical

34

Reaction-to-fire according to EN 13501-6: Class

EF011577 - Alphanumeric

35

Reaction-to-fire according to EN 13501-6: Smoke production

EF011578 - Alphanumeric

36

Reaction-to-fire according to EN 13501-6: Flaming droplets/particles

EF011579 - Alphanumeric

37

Reaction-to-fire according to EN 13501-6: Acidity

EF011580 - Alphanumeric

38

Halogen free according to EN 60754-1/2

EF009769 - Logical

39

Halogen free according to EN IEC 60754-2

EF003792 - Logical

40

Flame retardant

EF000471 - Alphanumeric

41

Low smoke (according to EN 61034-2)

EF008027 - Logical

42

Low smoke according to EN IEC 61034-2

EF003799 - Logical

43

Insulation integrity according to IEC 60331

EF003794 - Logical

44

Insulation integrity

EF003793 - Alphanumeric

45

Circuit integrity

EF001613 - Alphanumeric

46

Oil resistant (according to IEC 60811-404)

EF009842 - Logical

47

Outer diameter approximate (mm)

EF003921 - Numeric

48

Min. permitted bending radius, stationary application/permanent installation (mm)

EF011803 - Numeric

49

Weight (kg/km)

EF000167 - Numeric

50

Max. permitted conductor temperature (°C)

EF003803 - Numeric

51

Permitted cable outer temperature during assembling/handling (°C)

EF001685 - Range

52

Permitted cable outer temperature after assembling without vibration (°C)

EF001686 - Range

53

Nominal voltage U0 (kV)

EF001790 - Numeric

54

Nominal voltage U (kV)

EF001615 - Numeric

55

Nominal equivalent cross section of reinforcement (mm²)

EF013442 - Numeric

56

Suitable as installation cable

EF013771 - Logical

57

Certified for shipboard application

EF013772 - Logical

58

Suitable as medium-voltage cable

EF013773 - Logical

59

Suitable as high-voltage cable

EF013774 - Logical

60

Certified as airport lighting cable

EF013775 - Logical

61

Circuit integrity according to BS 6387 CWZ

EFUK0001 - Logical

62

Circuit integrity according to EN 50200

EFUK0002 - Alphanumeric

63

Circuit integrity according to EN 50200 annex E

EFUK0003 - Logical

64

Circuit integrity according to BS 8434-2

EFUK0004 - Logical

65

Circuit integrity according to BS 8491

EFUK0005 - Alphanumeric

66

Circuit integrity according to IEC 60331-3

EFUK0006 - Alphanumeric

67

Circuit integrity according to IEC 60331-21

EFUK0007 - Logical

68

Flame retardant according to EN 60332-1-2

EFUK0008 - Logical

69

Flame retardant according to EN 60332-3-21 (Cat A F/R)

EFUK0009 - Logical

70

Flame retardant according to EN 60332-3-22 (Cat A)

EFUK0010 - Logical

71

Flame retardant according to EN 60332-3-23 (Cat B)

EFUK0011 - Logical

72

Flame retardant according to EN 60332-3-24 (Cat C)

EFUK0012 - Logical

73

Flame retardant according to EN 60332-3-25 (Cat D)

EFUK0013 - Logical

74

Halogen free according to EN 60754-1

EFUK0014 - Logical

75

Halogen free according to EN 60754-2

EFUK0015 - Logical

76

Halogen free according to EN 60754-3

EFUK0016 - Logical
Synonyms

Airport lighting cable

Cable

Connection cable

Energy cable

Energy cable >= 1 kV, for permanent installation

Extra high voltage power cable

High voltage power cable

Ignition cable

Low voltage power cable

Marine cable

Medium voltage power cable

Offshore Cable

Power cable >= 1 kV, for permanent installation

Ship power cable

Shipboard cable

Shipboard low voltage cable