Switch disconnector EC000216

Published Low-voltage industrial controls and switchgear EG000017

Features 40

  1. 1

    Version as Main SwitchEF006981

    Yes or no

    YesNo
  2. 2

    Version as maintenance-/service switchEF006986

    Yes or no

    YesNo
  3. 3

    Version as safety switchEF006985

    Yes or no

    YesNo
  4. 4

    Version as emergency stop installationEF006959

    Yes or no

    YesNo
  5. 5

    Version as reversing switchEF009408

    Yes or no

    YesNo
  6. 6

    Number of SwitchesEF005586

    A number

  7. 7

    Max. rated operation voltage Ue ACEF007355

    A number in V

  8. 8

    Rated Operating VoltageEF001435

    A range, from and to, in V

  9. 9

    Rated permanent current IuEF001389

    A number in A

  10. 10

    Rated permanent current at AC-23, 400 VEF011777

    A number in A

  11. 11

    Rated permanent current at AC-21, 400 VEF009165

    A number in A

  12. 12

    Rated operation power at AC-3, 400 VEF001364

    A number in kW

  13. 13

    Rated short-time withstand current lcwEF007050

    A number in kA

  14. 14

    Rated operation power at AC-23, 400 VEF007027

    A number in kW

  15. 15

    Switching Power at 400 VEF009166

    A number in kW

  16. 16

    Conditioned rated short-circuit current IqEF001444

    A number in kA

  17. 17

    Number of PolesEF001391

    A number

  18. 18

    Number of auxiliary contacts as normally closed contactEF001377

    A number

  19. 19

    Number of auxiliary contacts as normally open contactEF001376

    A number

  20. 20

    Number of auxiliary contacts as change-over contactEF003531

    A number

  21. 21

    Motor Drive OptionalEF007386

    Yes or no

    YesNo
  22. 22

    Motor Drive IntegratedEF006697

    Yes or no

    YesNo
  23. 23

    Voltage Release OptionalEF007491

    Yes or no

    YesNo
  24. 24

    Device ConstructionEF008240

    Choose one value

    Complete device in housingSuitable for fixed installationSuitable for plug-in installationSuitable for drawout installation
  25. 25

    Suitable for floor mounting (no longer used)EF007243

    Yes or no

    YesNo
  26. 26

    Suitable for front mounting 4-holeEF007247

    Yes or no

    YesNo
  27. 27

    Suitable for front mounting centreEF007248

    Yes or no

    YesNo
  28. 28

    Suitable for distribution board installationEF007262

    Yes or no

    YesNo
  29. 29

    Suitable for Intermediate MountingEF007264

    Yes or no

    YesNo
  30. 30

    Colour Control ElementEF007167

    Choose one value

    GreyGreenRedWhiteBlackOther
  31. 31

    Type of control elementEF006976

    Choose one value

    Rotating ButtonPush buttonRocker leverToggleDoor coupling rotary driveShort thumb-gripLong turning handleKeyRockerOther
  32. 32

    InterlockableEF006281

    Yes or no

    YesNo
  33. 33

    Type of electrical connection of main circuitEF006819

    Choose one value

    Bolt connectionSpring clamp connectionRail connectionFlat plug-in connectionCable clampClamp bracketPCB connectionFrame clampScrew ConnectionMC4 connectorOther
  34. 34

    With pre-assembled cabling (no longer used)EF016444

    Yes or no

    YesNo
  35. 35

    Degree of protection (IP), front sideEF003118

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  36. 36

    Degree of protection (NEMA)EF011959

    Choose one value

    13R44X12Other
  37. 37

    WidthEF000008

    A number in mm

  38. 38

    HeightEF000040

    A number in mm

  39. 39

    DepthEF000049

    A number in mm

  40. 40

    Width in Number of Modular SpacingsEF002950

    A number

Codes after each name are ETIM feature codes. Use them, not the names, in product data.