Hazardous area switch EC000522
Explosion-proof device which connects or disconnects an electrically conductive connection by means of two electrically conductive materials or a semiconductor device.
Features 33
- 1
Housing MaterialEF001596
Choose one value
AluminiumBrassPlasticStainless SteelSteelOther - 2
ModelEF000010
Choose one value
Dahlander switchEmergency StopLevel switchOff SwitchPole switchPush buttonReverserReversing Dahlander switchReversing pole-switchReversing switch - 3
Number of PolesEF001391
A number
- 4
For ATEX classification, Ex-zone gasEF005728
Choose one value
0, 1, 21, 22 - 5
For ATEX classification, Ex-zone dustEF008404
Choose one value
20, 21, 2221, 2222 - 6
Degree of Protection (IP rating)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 7
Ex-classEF000854
Choose one value
IIAIIBIIC - 8
Protection class according to IEC 61140EF000004
Choose one value
IIIIII - 9
Temperature class (acc. directive 94/9/EC)EF001644
Choose one value
T1T2T3T4T5T6 - 10
Ambient temperatureEF002386
A range, from and to, in °C
- 11
Housing ColourEF000136
Choose one value
AluminiumBlackBlueBrownGreyRedStainless SteelWhiteYellowOther - 12
Mounting MethodEF000003
Choose one value
Built-inConductor barDIN railSurface mountingOther - 13
HeightEF000040
A number in mm
- 14
WidthEF000008
A number in mm
- 15
DepthEF000049
A number in mm
- 16
InterlockableEF006281
Yes or no
YesNo - 17
PadlockEF001163
Yes or no
YesNo - 18
Voltage typeEF000187
Choose one value
ACDCAC/DC - 19
Rated VoltageEF000228
A number in V
- 20
Rated currentEF000227
A number in A
- 21
Number of auxiliary contacts as normally open contactEF001376
A number
- 22
Number of auxiliary contacts as normally closed contactEF001377
A number
- 23
Connection TypeEF000124
Choose one value
CrimpingFlat plug-in connectionInsulation Displacement ConnectorScrewless TerminalScrew ConnectionSolderOther - 24
Type of control elementEF006976
Choose one value
Door coupling rotary driveKeyPush ButtonRockerRocker leverToggleRotating ButtonOther - 25
Version as emergency stop installationEF006959
Yes or no
YesNo - 26
Connectable conductor cross section multi-wiredEF007343
A range, from and to, in mm²
- 27
Connectable conductor cross section solid-coreEF007337
A range, from and to, in mm²
- 28
Activating undervoltage releaseEF015790
A range, from and to, in V
- 29
Activation shunt tripEF015789
A range, from and to, in V
- 30
Number of cable feed-through M20EF016221
A number
- 31
Number of cable feed-through M25EF016222
A number
- 32
Number of cable feed-through M32EF016223
A number
- 33
Number of cable feed-through M40EF016225
A number
Codes after each name are ETIM feature codes. Use them, not the names, in product data.