Feed-through terminal block EC000897

Features 21

  1. 1

    Connectable conductor cross section fine-strand without cable end sleeveEF007341

    A range, from and to, in mm²

  2. 2

    Connectable conductor cross section fine-strand with cable end sleeveEF007339

    A range, from and to, in mm²

  3. 3

    Wire cross section (solid)EF007337

    A range, from and to, in mm²

  4. 4

    Wire cross section (stranded)EF007343

    A range, from and to, in mm²

  5. 5

    Rated current InEF008250

    A number in A

  6. 6

    Voltage ratingEF000228

    A number in V

  7. 7

    Type of electrical connection 1EF002526

    Choose one value

    Bolt connectionInsulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionInsulation displacement connectionScrew connectionPlug-in connectionWrapped connection
  8. 8

    Type of electrical connection 2EF002527

    Choose one value

    Bolt connectionInsulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionInsulation displacement connectionScrew connectionPlug-in connectionWrapped connection
  9. 9

    Number of levelsEF002659

    A number

  10. 10

    Number of clamp positions per levelEF002660

    A number

  11. 11

    Mounting methodEF000003

    Choose one value

    Direct mountingG-railDIN rail (top hat rail) 15 mmDIN rail (top hat rail) 35 mmDIN rail (top hat rail)/G-rail TH35/G32Other
  12. 12

    Insulating element materialEF007543

    Choose one value

    DuroplastCeramicsThermoplasticOtherNone
  13. 13

    Operating temperatureEF002393

    A range, from and to, in °C

  14. 14

    Flammability class of insulation material according to UL94 (no longer used)EF002521

    Choose one value

    5VV0V1V2HBOther
  15. 15

    WidthEF000008

    A number in mm

  16. 16

    HeightEF000040

    A number in mm

  17. 17

    DepthEF000049

    A number in mm

  18. 18

    Explosion-proof execution Ex-e - confirmedEF008498

    Yes or no

    YesNo
  19. 19

    Cover plate requiredEF002525

    Yes or no

    YesNo
  20. 20

    ColorEF000007

    Choose one value

    BeigeBlackBrownBlueGreenGrayGreen/yellowMulti-coloredOrangeRed
  21. 21

    Internally connected stagesEF002661

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.