Surge protection device for power supply systems EC000941

Features 34

  1. 1

    DC network layoutEF009926

    Yes or no

    YesNo
  2. 2

    IT network layoutEF009927

    Yes or no

    YesNo
  3. 3

    TN network systemEF009928

    Yes or no

    YesNo
  4. 4

    System of the TN-C networkEF009929

    Yes or no

    YesNo
  5. 5

    System of the TN-C-S networkEF009933

    Yes or no

    YesNo
  6. 6

    System of the TN-S networkEF009930

    Yes or no

    YesNo
  7. 7

    TT network layoutEF009931

    Yes or no

    YesNo
  8. 8

    Different network layoutEF009932

    Yes or no

    YesNo
  9. 9

    Number of wires (without grounding)EF001148

    A number

  10. 10

    Nominal discharge current - peak value (8/20)EF004214

    A number in kA

  11. 11

    Max. discharge surge current (8/20)EF012274

    A number in kA

  12. 12

    Nominal voltage ACEF004220

    A number in V

  13. 13

    Nominal voltage DCEF004221

    A number in V

  14. 14

    Max. continuous voltage ACEF004198

    A number in V

  15. 15

    Max. continuous voltage DCEF004777

    A number in V

  16. 16

    Max. PV-voltageEF008795

    A number in V

  17. 17

    Voltage protection levelEF003525

    A number in kV

  18. 18

    Voltage protection level L-NEF004236

    A number in kV

  19. 19

    Voltage protection level N-PEEF008796

    A number in kV

  20. 20

    Max. overcurrent protection device, parallel connection (fuse)EF015962

    A number in A

  21. 21

    Max. overcurrent protection device, series connection (fuse)EF015963

    A number in A

  22. 22

    Short-circuit breaking capacity (Isccr)EF012627

    A number in kA

  23. 23

    Integrated short-circuit protectionEF016000

    Yes or no

    YesNo
  24. 24

    Integrated short-circuit protection selective to fuse gGEF016001

    A number in A

  25. 25

    Integrated back-up fuseEF008797

    Yes or no

    YesNo
  26. 26

    Leakage-current freeEF016002

    Yes or no

    YesNo
  27. 27

    Mounting methodEF000003

    Choose one value

    G-railDIN rail (top hat rail) 15 mmDIN rail (top hat rail) 35 mmDirect mountingBusbarOn basic elementNH00NH1ModuleSurface mounted
  28. 28

    Construction sizeEF002566

    Choose one value

    1 modular spacing1.5 modular units2 modular spacing3 modular spacing4 modular spacing4.5 modular units5 modular spacing6 modular spacing7 modular spacing8 modular spacing
  29. 29

    Conductor cross-section (single / multi-wire)EF008827

    A number in mm²

  30. 30

    Cross-section of flexible conduitEF008828

    A number in mm²

  31. 31

    With remote signalling contactEF000422

    Yes or no

    YesNo
  32. 32

    Signalling at the deviceEF004241

    Choose one value

    AcousticOpticalAcoustic and opticalNone
  33. 33

    Category type 2EF004230

    Yes or no

    YesNo
  34. 34

    Degree of protection (IP)EF005474

    Choose one value

    IP20IP21IP22IP23IP24IP2XCIP30IP31IP3XIP40

Codes after each name are ETIM feature codes. Use them, not the names, in product data.