Explosion proof emergency and security luminaire EC000981

Features 51

  1. 1

    Mounting methodEF000003

    Choose one value

    Surface mountingBuilt-inSurface mounting/recessed mountingLine lighting systemMounting rail
  2. 2

    Power supply system (no longer used)EF000233

    Choose one value

    CentralPeripheral
  3. 3

    Lamp typeEF002423

    Choose one value

    Incandescent lampCompact fluorescent lampFluorescent lampLED exchangeableLED not exchangeableOther
  4. 4

    With light sourceEF005905

    Yes or no

    YesNo
  5. 5

    Suitable for number of light sourcesEF006436

    A number

  6. 6

    Housing materialEF001596

    Choose one value

    AluminiumSteelStainless steelPlasticOther
  7. 7

    Voltage typeEF000187

    Choose one value

    ACDCAC/DC
  8. 8

    Nominal voltageEF005127

    A range, from and to, in V

  9. 9

    Type of control gearEF000381

    Choose one value

    Electronic transformerElectronic ballastLow-loss ballast inductiveLow-loss ballast compensatedLED operating device voltage-controlledLED operating device current-controlledMagnetic transformerNot required
  10. 10

    Suitable for labelling typeEF001277

    Choose one value

    StickerInsert sheet/plateAcrylic plateOtherNone
  11. 11

    Type of indicatorEF001278

    Choose one value

    Single/double-sidedOnly single-sided (no longer used)
  12. 12

    Recognition distanceEF008732

    A number in m

  13. 13

    Monitoring equipment (no longer used)EF008091

    Choose one value

    Test buttonAutomatic self testSafety module for monitoring (central feeded system)OtherNone
  14. 14

    Wiring systemEF002960

    Choose one value

    Standby switchingContinuous circuit/emergency circuit
  15. 15

    Energy efficiency class of the built-in lampEF012487

    Choose one value

    A++, A+, A (LED)Other
  16. 16

    Energy efficiency class of the provided exchangeable built-in lampEF012488

    Choose one value

    A++A+ABCDE
  17. 17

    Highest energy efficiency class of the exchangeable lampEF012489

    Choose one value

    A++A+ABCDE
  18. 18

    Lowest energy efficiency class of the exchangeable lampEF012490

    Choose one value

    A++A+ABCDE
  19. 19

    Power supply energy efficiency index (EEI) (no longer used)EF011875

    Choose one value

    A1 BATA1A2 BATA2A3B1B2COther
  20. 20

    Rated lifetime L70/B10 at 25 °C (no longer used)EF011869

    A number in h

  21. 21

    Rated lifetime L70/B50 at 25 °CEF011870

    A number in h

  22. 22

    Rated life time L80/B10 at 25 °C (no longer used)EF011871

    A number in h

  23. 23

    Rated lifetime L80/B50 at 25 °C (no longer used)EF011872

    A number in h

  24. 24

    Rated lifetime L90/B10 at 25 °C (no longer used)EF011873

    A number in h

  25. 25

    Rated lifetime L90/B50 at 25 °C (no longer used)EF011874

    A number in h

  26. 26

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  27. 27

    Impact strengthEF004293

    Choose one value

    IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09IK10
  28. 28

    Protection class according to IEC 61140EF000004

    Choose one value

    IIIIIINone
  29. 29

    Suitable for Ex-zone gasEF005728

    Choose one value

    0, 1, 21, 22None
  30. 30

    Suitable for Ex-zone dustEF008404

    Choose one value

    20, 21, 2221, 2222None
  31. 31

    Nominal operation timeEF012518

    A range, from and to, in h

  32. 32

    Suitable for lamp powerEF000280

    A range, from and to, in W

  33. 33

    Max. system powerEF009347

    A number in W

  34. 34

    Rated luminous flux according to IEC 62722-2-1 (no longer used)EF009349

    A number in lm

  35. 35

    Luminous flux in emergency modeEF008731

    A number in lm

  36. 36

    Colour of lightEF009350

    Choose one value

    BlueRedAmberGreenYellowRGBRGBWWhiteMulti-colouredOther
  37. 37

    Colour temperatureEF009346

    A range, from and to, in K

  38. 38

    Colour rendering index CRIEF000442

    Choose one value

    20-3940-5960-6970-7980-8990-100
  39. 39

    Power factorEF025740

    A number

  40. 40

    WidthEF000008

    A number in mm

  41. 41

    Height/depthEF001456

    A number in mm

  42. 42

    LengthEF001438

    A number in mm

  43. 43

    Outer diameterEF000015

    A number in mm

  44. 44

    Built-in widthEF000846

    A number in mm

  45. 45

    Built-in height/depthEF023518

    A number in mm

  46. 46

    Built-in lengthEF004265

    A number in mm

  47. 47

    Built-in diameterEF000943

    A number in mm

  48. 48

    Type of wiringEF011868

    Choose one value

    Suitable for loop-through wiringLoop-through wiring includedEnding
  49. 49

    Number of polesEF001391

    A number

  50. 50

    Conductor cross sectionEF000085

    A number in mm²

  51. 51

    Connection typeEF000124

    Choose one value

    CrimpingBlade terminalSolderInsulation displacement connectorScrewed terminalPush-in clampPinching contact (no longer used)Other

Codes after each name are ETIM feature codes. Use them, not the names, in product data.