Explosion proof emergency and security luminaire EC000981
Features 51
- 1
Mounting methodEF000003
Choose one value
Surface mountingBuilt-inSurface mounting/recessed mountingLine lighting systemMounting rail - 2
Power supply system (no longer used)EF000233
Choose one value
CentralPeripheral - 3
Lamp typeEF002423
Choose one value
Incandescent lampCompact fluorescent lampFluorescent lampLED exchangeableLED not exchangeableOther - 4
With light sourceEF005905
Yes or no
YesNo - 5
Suitable for number of light sourcesEF006436
A number
- 6
Housing materialEF001596
Choose one value
AluminiumSteelStainless steelPlasticOther - 7
Voltage typeEF000187
Choose one value
ACDCAC/DC - 8
Nominal voltageEF005127
A range, from and to, in V
- 9
Type of control gearEF000381
Choose one value
Electronic transformerElectronic ballastLow-loss ballast inductiveLow-loss ballast compensatedLED operating device voltage-controlledLED operating device current-controlledMagnetic transformerNot required - 10
Suitable for labelling typeEF001277
Choose one value
StickerInsert sheet/plateAcrylic plateOtherNone - 11
Type of indicatorEF001278
Choose one value
Single/double-sidedOnly single-sided (no longer used) - 12
Recognition distanceEF008732
A number in m
- 13
Monitoring equipment (no longer used)EF008091
Choose one value
Test buttonAutomatic self testSafety module for monitoring (central feeded system)OtherNone - 14
Wiring systemEF002960
Choose one value
Standby switchingContinuous circuit/emergency circuit - 15
Energy efficiency class of the built-in lampEF012487
Choose one value
A++, A+, A (LED)Other - 16
Energy efficiency class of the provided exchangeable built-in lampEF012488
Choose one value
A++A+ABCDE - 17
Highest energy efficiency class of the exchangeable lampEF012489
Choose one value
A++A+ABCDE - 18
Lowest energy efficiency class of the exchangeable lampEF012490
Choose one value
A++A+ABCDE - 19
Power supply energy efficiency index (EEI) (no longer used)EF011875
Choose one value
A1 BATA1A2 BATA2A3B1B2COther - 20
Rated lifetime L70/B10 at 25 °C (no longer used)EF011869
A number in h
- 21
Rated lifetime L70/B50 at 25 °CEF011870
A number in h
- 22
Rated life time L80/B10 at 25 °C (no longer used)EF011871
A number in h
- 23
Rated lifetime L80/B50 at 25 °C (no longer used)EF011872
A number in h
- 24
Rated lifetime L90/B10 at 25 °C (no longer used)EF011873
A number in h
- 25
Rated lifetime L90/B50 at 25 °C (no longer used)EF011874
A number in h
- 26
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 27
Impact strengthEF004293
Choose one value
IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09IK10 - 28
Protection class according to IEC 61140EF000004
Choose one value
IIIIIINone - 29
Suitable for Ex-zone gasEF005728
Choose one value
0, 1, 21, 22None - 30
Suitable for Ex-zone dustEF008404
Choose one value
20, 21, 2221, 2222None - 31
Nominal operation timeEF012518
A range, from and to, in h
- 32
Suitable for lamp powerEF000280
A range, from and to, in W
- 33
Max. system powerEF009347
A number in W
- 34
Rated luminous flux according to IEC 62722-2-1 (no longer used)EF009349
A number in lm
- 35
Luminous flux in emergency modeEF008731
A number in lm
- 36
Colour of lightEF009350
Choose one value
BlueRedAmberGreenYellowRGBRGBWWhiteMulti-colouredOther - 37
Colour temperatureEF009346
A range, from and to, in K
- 38
Colour rendering index CRIEF000442
Choose one value
20-3940-5960-6970-7980-8990-100 - 39
Power factorEF025740
A number
- 40
WidthEF000008
A number in mm
- 41
Height/depthEF001456
A number in mm
- 42
LengthEF001438
A number in mm
- 43
Outer diameterEF000015
A number in mm
- 44
Built-in widthEF000846
A number in mm
- 45
Built-in height/depthEF023518
A number in mm
- 46
Built-in lengthEF004265
A number in mm
- 47
Built-in diameterEF000943
A number in mm
- 48
Type of wiringEF011868
Choose one value
Suitable for loop-through wiringLoop-through wiring includedEnding - 49
Number of polesEF001391
A number
- 50
Conductor cross sectionEF000085
A number in mm²
- 51
Connection typeEF000124
Choose one value
CrimpingBlade terminalSolderInsulation displacement connectorScrewed terminalPush-in clampPinching contact (no longer used)Other
Codes after each name are ETIM feature codes. Use them, not the names, in product data.