Room temperature controller for bus system EC001101
Element for operation of the heating depending on the room temperature.
Features 34
- 1
Bus system KNXEF001499
Yes or no
YesNo - 2
Bus system KNX-RF (Radio Frequency)EF008855
Yes or no
YesNo - 3
Bus system KNX SecureEF018610
Yes or no
YesNo - 4
Bus system KNX Secure-RF (Radio Frequency)EF018611
Yes or no
YesNo - 5
Bus system radio frequencyEF001500
Yes or no
YesNo - 6
Bus system LONEF003831
Yes or no
YesNo - 7
Bus system PowernetEF001501
Yes or no
YesNo - 8
Other bus systemsEF003811
Choose one value
C-BusDuplineeNetEnOceanfree@homeGira OneIHCJUNG HOMELUXORlivingNHC - 9
Meshed bus networkEF027357
Yes or no
YesNo - 10
Supporting protocol for BACnet MS/TPEF016394
Yes or no
YesNo - 11
Radio frequency bidirectionalEF009466
Yes or no
YesNo - 12
Assembly arrangementEF000005
Choose one value
Basic elementBasic element with adaptor plateBasic element with housing topBasic element with complete housingBasic element with full cover plateBasic element with central cover plateControl elementOther - 13
Mounting methodEF000003
Choose one value
Built-inDRA (DIN-rail adaptor)Flush-mountedSurface mountedWall ductOther - 14
Local operation/hand operationEF003914
Yes or no
YesNo - 15
With anti-theft/dismantling protectionEF003837
Yes or no
YesNo - 16
With LED indicationEF005950
Yes or no
YesNo - 17
With displayEF000458
Yes or no
YesNo - 18
Number of digital inputsEF001992
A number
- 19
MaterialEF002169
Choose one value
GlassMetalPlasticStoneWoodOther - 20
Material qualityEF001257
Choose one value
AluminiumCopperDuroplastSlateStainless steelThermoplasticOther - 21
Surface protectionEF000139
Choose one value
AnodisedDecorGalvanisedLacqueredMetallicNano coatedSand-castOtherUntreated - 22
Surface finishingEF006569
Choose one value
GlossyMatt - 23
ColourEF000007
Choose one value
AluminiumAnthraciteBeigeBlackBlueBrassBronzeBrownChromeCopper - 24
RAL-number (similar)EF003882
A number
- 25
TransparentEF006243
Yes or no
YesNo - 26
External sensorEF023999
Yes or no
YesNo - 27
Manual set point settingEF003869
Yes or no
YesNo - 28
Presence buttonEF003879
Yes or no
YesNo - 29
Parallel-service possibleEF003878
Yes or no
YesNo - 30
Degree of protection (IP)EF005474
Choose one value
IP00IP20IP21IP22IP23IP24IP2XIP30IP31IP32 - 31
With bus connectionEF001504
Yes or no
YesNo - 32
Class of the temperature controlEF010595
Choose one value
IIIIIIIVVVIVIIVIII - 33
Standby power consumption (solstandby)EF010794
A number in W
- 34
Min. depth of built-in installation boxEF012278
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.