Metallic conduit EC001173
A metal conduit used for protecting electrical wiring.
Features 25
- 1
MaterialEF002169
Choose one value
AluminumStainless steelSteelOther - 2
Material qualityEF001257
Choose one value
AlMgSi 0.5 (3.3206)Stainless steel 304 (1.4301)Stainless steel 316 (1.4401)Stainless steel 316 Ti (1.4571)Steel (hot rolled steel)Steel (cold rolled steel)Other - 3
Surface protectionEF000139
Choose one value
AnodisedContinuously galvanizedGalvanic/electrolytic zinc platedHot-dip galvanizedLacqueredPlastic-coatedUntreatedOther - 4
Quality of surface coatingEF008706
Choose one value
UncoatedDuplex coatedGalvanized zinc coatedGalvanized zinc-iron coatedGalvanized zinc-nickel coatedOther - 5
Polished surfaceEF006437
Yes or no
YesNo - 6
Brushed surfaceEF008705
Yes or no
YesNo - 7
ModelEF000010
Choose one value
Pliable means I can bend the tube, but not permanently, because then the tube would break (e.g. after 20 bends)
Pliable corrugatedPliable corrugated with synthetic sheathRigid - 8
Connection 1EF000321
Choose one value
External thread metricInternal thread metricSleeveTube endOther - 9
Connection 2EF000322
Choose one value
External thread metricInternal thread metricSleeveTube endOther - 10
ColorEF000007
Choose one value
AluminumBlackBlueGreenGrayNickelOrangeRedStainless steelWhite - 11
Flush-mounted installationEF007517
Yes or no
YesNo - 12
Surface mountedEF003681
Yes or no
YesNo - 13
Suitable for machine and systems installationEF003683
Yes or no
YesNo - 14
Suitable for concrete installationEF003682
Yes or no
YesNo - 15
Suitable for subsurface installation (bitumen / hot asphalt)EF003684
Yes or no
YesNo - 16
Suitable for outdoor useEF003532
Yes or no
YesNo - 17
Suitable for subsurface installation (screed)EF003685
Yes or no
YesNo - 18
Suitable for installation on wood (no longer used)EF004162
Yes or no
YesNo - 19
Suitable for hollow wall installationEF003688
Yes or no
YesNo - 20
Suitable for underground installationEF003689
Yes or no
YesNo - 21
Compression strength class according to EN 61386-1EF018127
Choose one value
Extra light (class 1, 125 N)Light (Class 2, 320 N)Medium (class 3, 750 N)Heavy (class 4, 1250 N)Extra heavy (Class 5, 4000 N) - 22
Impact strength class according to EN 61386-1EF018126
Choose one value
Extra light (class 1 / 0.5 Joule)Light (class 2 / 1 Joule)Medium (class 3 / 2 Joule)Heavy (class 4 / 6 Joule)Extra heavy (class 5 / 20 Joule) - 23
Inside diameterEF000065
A number in mm
- 24
Outside diameterEF000015
A number in mm
- 25
Working temperatureEF001742
A range, from and to, in °C