Non-metallic corrugated flexible conduit EC001175

A flexible, ribbed plastic conduit for cable protection.

Features 45

  1. 1

    Nominal diameterEF005114

    A number in mm

  2. 2

    Nominal size in inchEF005462

    Choose one value

    1/8 inch1/4 inch5/16 inch3/8 inch1/2 inch5/8 inch3/4 inch7/8 inch15/16 inch1 inch
  3. 3

    MaterialEF002169

    Choose one value

    Ethylene tetrafluoroethylene (ETFE)Ethylene-Vinyl Acetate (EVA)Polyetheretherketone (PEEK)PFAPolyamide (PA)Polyethylene (PE)Polyolefin (LSF, LSZH, LS0H)Polypropylene (PP)Polyurethane (PUR)Polyvinyl Chloride (PVC)
  4. 4

    Material QualifierEF001257

    Choose one value

    PA6 (Polyamide 6) (no longer used)PA11 (Polyamide 11)PA12 (Polyamide 12)Other
  5. 5

    Compressive strengthEF001347

    A number in N

  6. 6

    Operating TemperatureEF001742

    A range, from and to, in °C

  7. 7

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  8. 8

    Bending radius, staticEF001744

    A number in mm

  9. 9

    Bending radius, dynamicEF009689

    A number in mm

  10. 10

    Oil resistantEF000022

    Yes or no

    YesNo
  11. 11

    ColourEF000007

    Choose one value

    BlackBlueBrownCopperColourlessGreenGreyOrangePurple/violetRed
  12. 12

    Sheathing materialEF001745

    Choose one value

    Copper braidingStainless steel braidingPolyamide (PA)Polyethylene (PE)Polyurethane (PUR)Polyvinyl Chloride (PVC)Steel braidedOtherNot sheathed
  13. 13

    Flame acceleratingEF001746

    Yes or no

    YesNo
  14. 14

    Bending strengthEF005660

    Choose one value

    PliablePliable, self recoveringFlexible
  15. 15

    Tensile strengthEF002782

    A number in N

  16. 16

    Lengthwise slottedEF007909

    Yes or no

    YesNo
  17. 17

    ShapeEF000051

    Choose one value

    FlatRoundOther
  18. 18

    Closable (two-part)EF008105

    Yes or no

    YesNo
  19. 19

    Halogen FreeEF000025

    Yes or no

    YesNo
  20. 20

    Flush-mounted installationEF007517

    Yes or no

    YesNo
  21. 21

    Surface mountedEF003681

    Yes or no

    YesNo
  22. 22

    Suitable for outdoor useEF003532

    Yes or no

    YesNo
  23. 23

    Hollow wallEF003688

    Yes or no

    YesNo
  24. 24

    Suitable for concrete installationEF003682

    Yes or no

    YesNo
  25. 25

    Suitable for subsurface installation (screed)EF003685

    Yes or no

    YesNo
  26. 26

    Suitable for underground installationEF003689

    Yes or no

    YesNo
  27. 27

    Electromagnetic shieldingEF018912

    Yes or no

    YesNo
  28. 28

    With draw wireEF009416

    Yes or no

    YesNo
  29. 29

    Shielding of electric fieldsEF018913

    Yes or no

    YesNo
  30. 30

    Inner heightEF006588

    A number in mm

  31. 31

    High conducting inner coatingEF007856

    Yes or no

    YesNo
  32. 32

    Inner widthEF006466

    A number in mm

  33. 33

    Fire resistance in accordance with UL 94 (no longer used)EF001743

    Choose one value

    HBV0V1V2Other
  34. 34

    Inner DiameterEF000065

    A number in mm

  35. 35

    Approved according to EN 61386-23EF008144

    Yes or no

    YesNo
  36. 36

    Outside heightEF008489

    A number in mm

  37. 37

    Approved according to LUL/British Standard (no longer used)EF003656

    Yes or no

    YesNo
  38. 38

    Outside widthEF008488

    A number in mm

  39. 39

    Approved according to Lloyd's Register TAEF003657

    Yes or no

    YesNo
  40. 40

    Outer diameterEF000015

    A number in mm

  41. 41

    Approved according to UTACEF003658

    Yes or no

    YesNo
  42. 42

    Approved according to DIN 5510EFDE0026

    Yes or no

    YesNo
  43. 43

    Approved according to VdTÜV/GGVSEBEFDE0027

    Yes or no

    YesNo
  44. 44

    Approved according to NF F 16-101EFFR0016

    Yes or no

    YesNo
  45. 45

    Approved according to CSAEFNA0009

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.