Graphic panel EC001412

Features 74

  1. 1

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  2. 2

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  3. 3

    Supply voltage DCEF007534

    A range, from and to, in V

  4. 4

    Voltage type (supply voltage)EF002991

    Choose one value

    ACAC/DCDC
  5. 5

    Number of HW-interfaces industrial EthernetEF003020

    A number

  6. 6

    Number of interfaces PROFINETEF006932

    A number

  7. 7

    Number of HW-interfaces RS-232EF003021

    A number

  8. 8

    Number of HW-interfaces RS-422EF003022

    A number

  9. 9

    Number of HW-interfaces RS-485EF003023

    A number

  10. 10

    Number of HW-interfaces serial TTYEF003024

    A number

  11. 11

    Number of HW-interfaces USBEF003025

    A number

  12. 12

    Number of HW-interfaces parallelEF003026

    A number

  13. 13

    Number of HW-interfaces wirelessEF006933

    A number

  14. 14

    Number of HW-interfaces otherEF003027

    A number

  15. 15

    With SW interfacesEF003121

    Yes or no

    YesNo
  16. 16

    Supporting protocol for TCP/IPEF003050

    Yes or no

    YesNo
  17. 17

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  18. 18

    Supporting protocol for CANEF003053

    Yes or no

    YesNo
  19. 19

    Supporting protocol for INTERBUSEF003054

    Yes or no

    YesNo
  20. 20

    Supporting protocol for ASIEF003051

    Yes or no

    YesNo
  21. 21

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  22. 22

    Supporting protocol for ModbusEF003057

    Yes or no

    YesNo
  23. 23

    Supporting protocol for Data-HighwayEF003058

    Yes or no

    YesNo
  24. 24

    Supporting protocol for DeviceNetEF003059

    Yes or no

    YesNo
  25. 25

    Supporting protocol for SUCONETEF003060

    Yes or no

    YesNo
  26. 26

    Supporting protocol for LONEF003017

    Yes or no

    YesNo
  27. 27

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  28. 28

    Supporting protocol for PROFINET CBAEF007524

    Yes or no

    YesNo
  29. 29

    Supporting protocol for SERCOSEF006657

    Yes or no

    YesNo
  30. 30

    Supporting protocol for Foundation FieldbusEF007522

    Yes or no

    YesNo
  31. 31

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  32. 32

    Supporting protocol for AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  33. 33

    Supporting protocol for DeviceNet SafetyEF007520

    Yes or no

    YesNo
  34. 34

    Supporting protocol for INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  35. 35

    Supporting protocol for PROFIsafeEF007526

    Yes or no

    YesNo
  36. 36

    Supporting protocol for SafetyBUS pEF007527

    Yes or no

    YesNo
  37. 37

    Supporting protocol for other bus systemsEF003062

    Yes or no

    YesNo
  38. 38

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  39. 39

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  40. 40

    Mobile communication standard GPRSEF008523

    Yes or no

    YesNo
  41. 41

    Mobile communication standard 2G (GSM)EF008524

    Yes or no

    YesNo
  42. 42

    Mobile communication standard 3G (UMTS)EF008525

    Yes or no

    YesNo
  43. 43

    IO link masterEF007298

    Yes or no

    YesNo
  44. 44

    Type of displayEF008244

    Choose one value

    LCDSTNTFTOther
  45. 45

    Colour displayEF003097

    Yes or no

    YesNo
  46. 46

    Number of colours of the displayEF003098

    A number

  47. 47

    Number of grey-scales/blue-scales of displayEF008515

    A number

  48. 48

    Screen diagonalEF002032

    A number in in

  49. 49

    Number of pixels, horizontalEF003099

    A number

  50. 50

    Number of pixels, verticalEF003100

    A number

  51. 51

    Usable project memory/user memoryEF003108

    A number in kByte

  52. 52

    With numeric keyboardEF003105

    Yes or no

    YesNo
  53. 53

    With alpha numeric keyboardEF003106

    Yes or no

    YesNo
  54. 54

    Number of function buttons, programmableEF003103

    A number

  55. 55

    Number of buttons with LEDEF009259

    A number

  56. 56

    Number of system buttonsEF009260

    A number

  57. 57

    With touch screenEF003102

    Yes or no

    YesNo
  58. 58

    With message indicationEF003109

    Yes or no

    YesNo
  59. 59

    With message system (incl. buffer and confirmation)EF003110

    Yes or no

    YesNo
  60. 60

    Process value representation (output) possibleEF003111

    Yes or no

    YesNo
  61. 61

    Process default value (input) possibleEF003112

    Yes or no

    YesNo
  62. 62

    With recipesEF003113

    Yes or no

    YesNo
  63. 63

    Number of password levelsEF003114

    A number

  64. 64

    With printer outputEF003115

    Yes or no

    YesNo
  65. 65

    Number of online languagesEF003116

    A number

  66. 66

    Additional software components, loadableEF003117

    Yes or no

    YesNo
  67. 67

    Degree of protection (IP), front sideEF003118

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  68. 68

    Operating temperatureEF002393

    A range, from and to, in °C

  69. 69

    Suitable for rail mountingEF003972

    Yes or no

    YesNo
  70. 70

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  71. 71

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  72. 72

    Width of the frontEF003651

    A number in mm

  73. 73

    Height of the frontEF003652

    A number in mm

  74. 74

    Built-in depthEF000218

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.