Graphic panel EC001412

Equipment for the operating of machinery and facilities, with front-sided full graphic capable display, that is stationary fixed.

Features 89

  1. 1

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  2. 2

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  3. 3

    Supply voltage DCEF007534

    A range, from and to, in V

  4. 4

    Voltage type of supply voltageEF002991

    Choose one value

    ACAC/DCDC
  5. 5

    Power ConsumptionEF000346

    A number in W

  6. 6

    Number of HW-interfaces industrial EthernetEF003020

    A number

  7. 7

    Number of HW-interfaces PROFINETEF006932

    A number

  8. 8

    Number of HW-interfaces RS-232EF003021

    A number

  9. 9

    Number of HW-interfaces RS-422EF003022

    A number

  10. 10

    Number of HW-interfaces RS-485EF003023

    A number

  11. 11

    Number of HW-interfaces serial TTYEF003024

    A number

  12. 12

    Number of HW-interfaces USBEF003025

    A number

  13. 13

    Number of HW-interfaces parallelEF003026

    A number

  14. 14

    Number of HW-interfaces WirelessEF006933

    A number

  15. 15

    Number of HW-interfaces otherEF003027

    A number

  16. 16

    With SW interfacesEF003121

    Yes or no

    YesNo
  17. 17

    Supporting protocol for EtherCATEF017564

    Yes or no

    YesNo
  18. 18

    Supporting protocol for TCP/IPEF003050

    Yes or no

    YesNo
  19. 19

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  20. 20

    Supporting protocol for CANEF003053

    Yes or no

    YesNo
  21. 21

    Supporting protocol for INTERBUSEF003054

    Yes or no

    YesNo
  22. 22

    Supporting protocol for ASIEF003051

    Yes or no

    YesNo
  23. 23

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  24. 24

    Supporting Protocol for ModbusEF003057

    Yes or no

    YesNo
  25. 25

    Supporting protocol for Data-HighwayEF003058

    Yes or no

    YesNo
  26. 26

    Supporting protocol for DeviceNetEF003059

    Yes or no

    YesNo
  27. 27

    Supporting protocol for SUCONETEF003060

    Yes or no

    YesNo
  28. 28

    Supporting protocol for LONEF003017

    Yes or no

    YesNo
  29. 29

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  30. 30

    Supporting protocol for PROFINET CBAEF007524

    Yes or no

    YesNo
  31. 31

    Supporting protocol for SERCOSEF006657

    Yes or no

    YesNo
  32. 32

    Supporting protocol for Foundation FieldbusEF007522

    Yes or no

    YesNo
  33. 33

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  34. 34

    Supporting protocol for AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  35. 35

    Supporting protocol for DeviceNet SafetyEF007520

    Yes or no

    YesNo
  36. 36

    Supporting protocol for INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  37. 37

    Supporting protocol for PROFIsafeEF007526

    Yes or no

    YesNo
  38. 38

    Supporting protocol for SafetyBUS pEF007527

    Yes or no

    YesNo
  39. 39

    Supporting protocol for other bus systemsEF003062

    Yes or no

    YesNo
  40. 40

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  41. 41

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  42. 42

    Radio standard GPRSEF008523

    Yes or no

    YesNo
  43. 43

    Radio standard GSMEF008524

    Yes or no

    YesNo
  44. 44

    Radio standard UMTSEF008525

    Yes or no

    YesNo
  45. 45

    IO link masterEF007298

    Yes or no

    YesNo
  46. 46

    Type of displayEF008244

    Choose one value

    LCDSTNTFTOther
  47. 47

    With colour displayEF003097

    Yes or no

    YesNo
  48. 48

    Number of colours of the displayEF003098

    A number

  49. 49

    Number of grey-scales/blue-scales of displayEF008515

    A number

  50. 50

    Screen diagonalEF002032

    A number in inch

  51. 51

    Number of pixels, horizontalEF003099

    A number

  52. 52

    Number of pixels, verticalEF003100

    A number

  53. 53

    Useful project memory/user memoryEF003108

    A number in kByte

  54. 54

    With numeric keyboardEF003105

    Yes or no

    YesNo
  55. 55

    With alpha numeric keyboardEF003106

    Yes or no

    YesNo
  56. 56

    Number of function buttons, programmableEF003103

    A number

  57. 57

    Number of buttons with LEDEF009259

    A number

  58. 58

    Number of system buttonsEF009260

    A number

  59. 59

    Touch technologyEF010884

    Choose one value

    NoneInfrared touchCapacitive multitouchResistive touchOther
  60. 60

    With message indicationEF003109

    Yes or no

    YesNo
  61. 61

    With message system (incl. buffer and confirmation)EF003110

    Yes or no

    YesNo
  62. 62

    Process value representation (output) possibleEF003111

    Yes or no

    YesNo
  63. 63

    Process default value (input) possibleEF003112

    Yes or no

    YesNo
  64. 64

    With recipesEF003113

    Yes or no

    YesNo
  65. 65

    Number of password levelsEF003114

    A number

  66. 66

    Printer output availableEF003115

    Yes or no

    YesNo
  67. 67

    Number of online languagesEF003116

    A number

  68. 68

    Additional software components, loadableEF003117

    Yes or no

    YesNo
  69. 69

    Degree of protection (IP), front sideEF003118

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  70. 70

    Degree of protection (NEMA), front sideEF011961

    Choose one value

    1233R44X66P1213
  71. 71

    Certified for UL hazardous location class I (no longer used)EF017622

    Yes or no

    YesNo
  72. 72

    Certified for UL hazardous location class II (no longer used)EF017625

    Yes or no

    YesNo
  73. 73

    Certified for UL hazardous location class III (no longer used)EF017627

    Yes or no

    YesNo
  74. 74

    Certified for UL hazardous location division 1 (no longer used)EF017628

    Yes or no

    YesNo
  75. 75

    Certified for UL hazardous location division 2 (no longer used)EF017629

    Yes or no

    YesNo
  76. 76

    Certified for UL hazardous location group A (acetylene) (no longer used)EF017632

    Yes or no

    YesNo
  77. 77

    Certified for UL hazardous location group B (Hydrogen) (no longer used)EF017633

    Yes or no

    YesNo
  78. 78

    Certified for UL hazardous location group C (ethylene) (no longer used)EF017635

    Yes or no

    YesNo
  79. 79

    Certified for UL hazardous location group D (propane) (no longer used)EF017636

    Yes or no

    YesNo
  80. 80

    Certified for UL hazardous location group E (metal dusts) (no longer used)EF017637

    Yes or no

    YesNo
  81. 81

    Certified for UL hazardous location group F (carbonaceous dusts) (no longer used)EF017638

    Yes or no

    YesNo
  82. 82

    Certified for UL hazardous location group G (non-conductive dusts) (no longer used)EF017639

    Yes or no

    YesNo
  83. 83

    Operating temperatureEF002393

    A range, from and to, in °C

  84. 84

    Rail mounting possibleEF003972

    Yes or no

    YesNo
  85. 85

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  86. 86

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  87. 87

    Width of the frontEF003651

    A number in mm

  88. 88

    Height of the frontEF003652

    A number in mm

  89. 89

    Recess depthEF000218

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.