SPS-Kommunikations-Modul EC001423

A communication module designed for use within programmable logic control systems, facilitating the exchange of data and commands between various devices and systems. This component enhances the networking capabilities of the control system, enabling integration with other hardware and software solutions. It supports various communication protocols to ensure compatibility and efficient data transfer, playing a crucial role in the overall functionality and performance of automated processes. The communication module can be utilized in diverse applications, enhancing connectivity and operational efficiency in industrial environments.

Features 68

  1. 1

    Anzahl der HW-Schnittstellen Industrial EthernetEF003020

    A number

  2. 2

    Anzahl der Schnittstellen PROFINETEF006932

    A number

  3. 3

    Anzahl der HW-Schnittstellen CANEF017563

    A number

  4. 4

    Anzahl der HW-Schnittstellen seriell RS-232EF003021

    A number

  5. 5

    Anzahl der HW-Schnittstellen seriell RS-422EF003022

    A number

  6. 6

    Anzahl der HW-Schnittstellen seriell RS-485EF003023

    A number

  7. 7

    Anzahl der HW-Schnittstellen seriell TTYEF003024

    A number

  8. 8

    Anzahl der HW-Schnittstellen USBEF003025

    A number

  9. 9

    Anzahl der HW-Schnittstellen parallelEF003026

    A number

  10. 10

    Anzahl der HW-Schnittstellen WirelessEF006933

    A number

  11. 11

    Anzahl der HW-Schnittstellen sonstigeEF003027

    A number

  12. 12

    Mit optischer SchnittstelleEF003028

    Yes or no

    YesNo
  13. 13

    Unterstützt Protokoll für EtherCATEF017564

    Yes or no

    YesNo
  14. 14

    Unterstützt Protokoll für TCP/IPEF003050

    Yes or no

    YesNo
  15. 15

    Unterstützt Protokoll für PROFIBUSEF003052

    Yes or no

    YesNo
  16. 16

    Unterstützt Protokoll für CANEF003053

    Yes or no

    YesNo
  17. 17

    Unterstützt Protokoll für INTERBUSEF003054

    Yes or no

    YesNo
  18. 18

    Unterstützt Protokoll für ASIEF003051

    Yes or no

    YesNo
  19. 19

    Unterstützt Protokoll für KNXEF003055

    Yes or no

    YesNo
  20. 20

    Unterstützt Protokoll für ModbusEF003057

    Yes or no

    YesNo
  21. 21

    Unterstützt Protokoll für Data-HighwayEF003058

    Yes or no

    YesNo
  22. 22

    Unterstützt Protokoll für DeviceNetEF003059

    Yes or no

    YesNo
  23. 23

    Unterstützt Protokoll für SUCONETEF003060

    Yes or no

    YesNo
  24. 24

    Unterstützt Protokoll für LONEF003017

    Yes or no

    YesNo
  25. 25

    Unterstützt Protokoll für PROFINET IOEF007525

    Yes or no

    YesNo
  26. 26

    Unterstützt Protokoll für PROFINET CBAEF007524

    Yes or no

    YesNo
  27. 27

    Unterstützt Protokoll für SERCOSEF006657

    Yes or no

    YesNo
  28. 28

    Unterstützt Protokoll für Foundation FieldbusEF007522

    Yes or no

    YesNo
  29. 29

    Unterstützt Protokoll für EtherNet/IPEF007521

    Yes or no

    YesNo
  30. 30

    Unterstützt Protokoll für AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  31. 31

    Unterstützt Protokoll für DeviceNet SafetyEF007520

    Yes or no

    YesNo
  32. 32

    Unterstützt Protokoll für INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  33. 33

    Unterstützt Protokoll für PROFIsafeEF007526

    Yes or no

    YesNo
  34. 34

    Unterstützt Protokoll für SafetyBUS pEF007527

    Yes or no

    YesNo
  35. 35

    Unterstützt Protokoll für sonstige BussystemeEF003062

    Yes or no

    YesNo
  36. 36

    Funkstandard BluetoothEF007178

    Yes or no

    YesNo
  37. 37

    Funkstandard WLAN 802.11EF007179

    Yes or no

    YesNo
  38. 38

    Mobilfunkstandard GPRSEF008523

    Yes or no

    YesNo
  39. 39

    Mobilfunkstandard 2G (GSM)EF008524

    Yes or no

    YesNo
  40. 40

    Mobilfunkstandard 3G (UMTS)EF008525

    Yes or no

    YesNo
  41. 41

    IO-Link MasterEF007298

    Yes or no

    YesNo
  42. 42

    RedundanzfähigkeitEF003156

    Yes or no

    YesNo
  43. 43

    Art der DatenübertragungEF008225

    Choose one value

    seriellparallelBaugruppenträger-Erweiterungsonstige
  44. 44

    ÜbertragungsrateEF003271

    A number in kBit/s

  45. 45

    Mit PotentialtrennungEF003272

    Yes or no

    YesNo
  46. 46

    SIL nach IEC 61508EF009889

    Choose one value

    1234ohne
  47. 47

    Geeignet für SicherheitsfunktionenEF001597

    Yes or no

    YesNo
  48. 48

    Performance Level nach EN ISO 13849-1EF007399

    Choose one value

    Level aLevel bLevel cLevel dLevel eohne
  49. 49

    Zugehöriges Betriebsmittel (Ex ia)EF004141

    Yes or no

    YesNo
  50. 50

    Zugehöriges Betriebsmittel (Ex ib)EF004142

    Yes or no

    YesNo
  51. 51

    Explosionsschutz-Kategorie für GasEF003997

    Choose one value

    ATEX Gas-Ex-Schutz, Kat. 1GATEX Gas-Ex-Schutz, Kat. 2GATEX Gas-Ex-Schutz, Kat. 3Gsonstigeohne
  52. 52

    Explosionsschutz-Kategorie für StaubEF003998

    Choose one value

    ATEX Staub-Ex-Schutz, Kat. 1DATEX Staub-Ex-Schutz, Kat. 2DATEX Staub-Ex-Schutz, Kat. 3Dsonstigeohne
  53. 53

    LeistungsaufnahmeEF000346

    A number in W

  54. 54

    BreiteEF000008

    A number in mm

  55. 55

    HöheEF000040

    A number in mm

  56. 56

    TiefeEF000049

    A number in mm

  57. 57

    Zertifiziert für UL-Gefahrenbereich Klasse IEFNA0014

    Yes or no

    YesNo
  58. 58

    Zertifiziert für UL-Gefahrenbereich Klasse IIEFNA0015

    Yes or no

    YesNo
  59. 59

    Zertifiziert für UL-Gefahrenbereich Division 1EFNA0016

    Yes or no

    YesNo
  60. 60

    Zertifiziert für UL-Gefahrenbereich Division 2EFNA0017

    Yes or no

    YesNo
  61. 61

    Zertifiziert für UL-Gefahrenbereich Klasse IIIEFNA0018

    Yes or no

    YesNo
  62. 62

    Zertifiziert für UL-Gefahrenbereich Gruppe A (Acetylen)EFNA0019

    Yes or no

    YesNo
  63. 63

    Zertifiziert für UL-Gefahrenbereich Gruppe B (Wasserstoff)EFNA0020

    Yes or no

    YesNo
  64. 64

    Zertifiziert für UL-Gefahrenbereich Gruppe C (Ethylen)EFNA0021

    Yes or no

    YesNo
  65. 65

    Zertifiziert für UL-Gefahrenbereich Gruppe D (Propan)EFNA0022

    Yes or no

    YesNo
  66. 66

    Zertifiziert für UL-Gefahrenbereich Gruppe E (Metallstäube)EFNA0023

    Yes or no

    YesNo
  67. 67

    Zertifiziert für UL-Gefahrenbereich Gruppe F (kohlenstoffhaltige Stäube)EFNA0024

    Yes or no

    YesNo
  68. 68

    Zertifiziert für UL-Gefahrenbereich Gruppe G (nichtleitende Stäube)EFNA0025

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.