Switching relay EC001437

A relay used to control electrical circuits by opening and closing contacts.

Features 30

  1. 1

    Type of electric connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew ConnectionWelding connectionPlug-in connection
  2. 2

    Tightening torqueEF005520

    A range, from and to, in Nm

  3. 3

    Complete with socketEF003359

    Yes or no

    YesNo
  4. 4

    With detachable clampsEF003340

    Yes or no

    YesNo
  5. 5

    With LED indicationEF005950

    Yes or no

    YesNo
  6. 6

    Rated control supply voltage at AC 50 HzEF003978

    A range, from and to, in V

  7. 7

    Rated control supply voltage at AC 60 HzEF003979

    A range, from and to, in V

  8. 8

    Rated control supply voltage at DCEF003980

    A range, from and to, in V

  9. 9

    Voltage type for actuatingEF008242

    Choose one value

    ACDCAC/DC
  10. 10

    Drive, polarizationEF003355

    Choose one value

    PolarizedPolarity free
  11. 11

    Drive, switching attitudeEF003356

    Choose one value

    BistableMono stableRemanence
  12. 12

    Number of contacts as normally closed contactEF008255

    A number

  13. 13

    Number of contacts as normally open contactEF008256

    A number

  14. 14

    Number of contacts as change-over contactEF008257

    A number

  15. 15

    Type of switch contactEF003358

    Choose one value

    In the context of a switching relay, single contact and double contact normally refer to the design of an individual relay contact, i.e. whether the circuit is closed via one or two parallel contact points. Single contact: One contact pair forms a single contact point. When the relay closes, the movable and fixed contacts touch at one point. Double contact: The contact is designed so that two contact points close simultaneously and in parallel. The movable contact may, for example, have a bifurcated design. This is not the same as “single-pole / double-pole” or “one NO contact / two NO contacts.” A double contact can still switch only one electrical circuit.

    Single contactDouble contactOther
  16. 16

    With forced-guided contactsEF003357

    Yes or no

    YesNo
  17. 17

    Material of contact insertEF008521

    Choose one value

    CeramicsUrea FormaldehydeThermoplasticOther
  18. 18

    Material contactEF007544

    Choose one value

    Beryllium copperBrassBronzeConstantan alloyCopperIronNickelPhosphor bronzeSilver tin oxide (AgSnO2)Silver cadmium oxide (AgCdO)
  19. 19

    Material of contact surfaceEF004020

    Choose one value

    UntreatedBrassBronzeGoldNickelNickel/goldPalladiumSilverTinZincOther
  20. 20

    Voltage type (operating voltage)EF005294

    Choose one value

    ACDCAC/DC
  21. 21

    Operating voltage at AC 50 HzEF008206

    A range, from and to, in V

  22. 22

    Operating voltage at AC 60 HzEF008207

    A range, from and to, in V

  23. 23

    Operating voltage at DCEF008208

    A range, from and to, in V

  24. 24

    Nominal CurrentEF000001

    A number in A

  25. 25

    Max. starting currentEF001732

    A number in A

  26. 26

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  27. 27

    Relay technology category according to IEC 61810-7EF016748

    Choose one value

    RT 0RT IRT IIRT IIIRT IVRT V
  28. 28

    WidthEF000008

    A number in mm

  29. 29

    HeightEF000040

    A number in mm

  30. 30

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.