Switching relay EC001437
A relay used to control electrical circuits by opening and closing contacts.
Features 30
- 1
Type of electric connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew ConnectionWelding connectionPlug-in connection - 2
Tightening torqueEF005520
A range, from and to, in Nm
- 3
Complete with socketEF003359
Yes or no
YesNo - 4
With detachable clampsEF003340
Yes or no
YesNo - 5
With LED indicationEF005950
Yes or no
YesNo - 6
Rated control supply voltage at AC 50 HzEF003978
A range, from and to, in V
- 7
Rated control supply voltage at AC 60 HzEF003979
A range, from and to, in V
- 8
Rated control supply voltage at DCEF003980
A range, from and to, in V
- 9
Voltage type for actuatingEF008242
Choose one value
ACDCAC/DC - 10
Drive, polarizationEF003355
Choose one value
PolarizedPolarity free - 11
Drive, switching attitudeEF003356
Choose one value
BistableMono stableRemanence - 12
Number of contacts as normally closed contactEF008255
A number
- 13
Number of contacts as normally open contactEF008256
A number
- 14
Number of contacts as change-over contactEF008257
A number
- 15
Type of switch contactEF003358
Choose one value
In the context of a switching relay, single contact and double contact normally refer to the design of an individual relay contact, i.e. whether the circuit is closed via one or two parallel contact points. Single contact: One contact pair forms a single contact point. When the relay closes, the movable and fixed contacts touch at one point. Double contact: The contact is designed so that two contact points close simultaneously and in parallel. The movable contact may, for example, have a bifurcated design. This is not the same as “single-pole / double-pole” or “one NO contact / two NO contacts.” A double contact can still switch only one electrical circuit.
Single contactDouble contactOther - 16
With forced-guided contactsEF003357
Yes or no
YesNo - 17
Material of contact insertEF008521
Choose one value
CeramicsUrea FormaldehydeThermoplasticOther - 18
Material contactEF007544
Choose one value
Beryllium copperBrassBronzeConstantan alloyCopperIronNickelPhosphor bronzeSilver tin oxide (AgSnO2)Silver cadmium oxide (AgCdO) - 19
Material of contact surfaceEF004020
Choose one value
UntreatedBrassBronzeGoldNickelNickel/goldPalladiumSilverTinZincOther - 20
Voltage type (operating voltage)EF005294
Choose one value
ACDCAC/DC - 21
Operating voltage at AC 50 HzEF008206
A range, from and to, in V
- 22
Operating voltage at AC 60 HzEF008207
A range, from and to, in V
- 23
Operating voltage at DCEF008208
A range, from and to, in V
- 24
Nominal CurrentEF000001
A number in A
- 25
Max. starting currentEF001732
A number in A
- 26
Degree of Protection (IP rating)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 27
Relay technology category according to IEC 61810-7EF016748
Choose one value
RT 0RT IRT IIRT IIIRT IVRT V - 28
WidthEF000008
A number in mm
- 29
HeightEF000040
A number in mm
- 30
DepthEF000049
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.