Koblingsrelé EC001437

A relay used to control electrical circuits by opening and closing contacts.

Features 30

  1. 1

    Type strømtilkoblingEF003961

    Choose one value

    Gjennomgående forbindelseTilkobling med fjærklemmeTilkobling for kabelskoKlammerforbindelseLoddefaneforbindelseKretskorttilkoblingKroneplintkoblingSkrukoblingSveiseforbindelseStikktilkobling
  2. 2

    TiltrekkingsmomentEF005520

    A range, from and to, in Nm

  3. 3

    Komplett apparat med sokkelEF003359

    Yes or no

    YesNo
  4. 4

    Med avtakbare klemmerEF003340

    Yes or no

    YesNo
  5. 5

    Med LED-visningEF005950

    Yes or no

    YesNo
  6. 6

    Nominell matespenning ved AC 50 HzEF003978

    A range, from and to, in V

  7. 7

    Nominell matespenning ved AC 60 HzEF003979

    A range, from and to, in V

  8. 8

    Nominell matespenning ved DCEF003980

    A range, from and to, in V

  9. 9

    Spenningstype for betjeningEF008242

    Choose one value

    ACDCAC/DC
  10. 10

    Drift, polarisasjonEF003355

    Choose one value

    PolarisertUpolarisert
  11. 11

    Driftens svingningskarakteristikkEF003356

    Choose one value

    BistabilMonostabilRemanens
  12. 12

    Antall NC-kontakterEF008255

    A number

  13. 13

    Antall NO-kontakterEF008256

    A number

  14. 14

    Antall vekselkontakterEF008257

    A number

  15. 15

    BrytekontakterEF003358

    Choose one value

    In the context of a switching relay, single contact and double contact normally refer to the design of an individual relay contact, i.e. whether the circuit is closed via one or two parallel contact points. Single contact: One contact pair forms a single contact point. When the relay closes, the movable and fixed contacts touch at one point. Double contact: The contact is designed so that two contact points close simultaneously and in parallel. The movable contact may, for example, have a bifurcated design. This is not the same as “single-pole / double-pole” or “one NO contact / two NO contacts.” A double contact can still switch only one electrical circuit.

    EnkeltkontaktDobbeltkontaktAndre
  16. 16

    Tvangsførte kontakterEF003357

    Yes or no

    YesNo
  17. 17

    Materiale kontaktinnsatsEF008521

    Choose one value

    KeramikkDuroplastTermoplastAndre
  18. 18

    Materiale i kontaktEF007544

    Choose one value

    Beryllium, kobberMessingBronseKonstantanlegeringKobberJernNikkelFosforbronseSølvtinnoksid (AgSnO2)Sølvkadmiumoksid (AgCdO)
  19. 19

    Kontaktoverflatens materialeEF004020

    Choose one value

    UbehandletMessingBronseGullNikkelNikkel/gullPalladiumSølvTinnSinkAndre
  20. 20

    Type driftspenningEF005294

    Choose one value

    ACDCAC/DC
  21. 21

    Driftspenning ved AC 50 HzEF008206

    A range, from and to, in V

  22. 22

    Driftspenning ved AC 60 HzEF008207

    A range, from and to, in V

  23. 23

    Driftspenning ved DCEF008208

    A range, from and to, in V

  24. 24

    Nominell strømEF000001

    A number in A

  25. 25

    Maks startstrømEF001732

    A number in A

  26. 26

    Beskyttelsesklasse IPEF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  27. 27

    Reléteknologi kategori i henhold til IEC 61810-7EF016748

    Choose one value

    RT 0RT IRT IIRT IIIRT IVRT V
  28. 28

    BreddeEF000008

    A number in mm

  29. 29

    HøydeEF000040

    A number in mm

  30. 30

    DybdeEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.