Voltage monitoring relay EC001438
A relay that monitors voltage levels and triggers alarms or actions.
Features 35
- 1
Type of electric connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew connectionWelding connectionPlug-in connection - 2
With detachable clampsEF003340
Yes or no
YesNo - 3
External power supply requiredEF003292
Yes or no
YesNo - 4
Voltage type (supply voltage)EF002991
Choose one value
ACDCAC/DC - 5
Supply voltage AC 50 HzEF007532
A range, from and to, in V
- 6
Supply voltage AC 60 HzEF007533
A range, from and to, in V
- 7
Supply voltage DCEF007534
A range, from and to, in V
- 8
Voltage measuring range 1EF006134
A range, from and to, in V
- 9
Voltage measuring range 2EF006135
A range, from and to, in V
- 10
Type of voltage measuring rangeEF003399
Choose one value
ACDCAC/DC - 11
Response value voltageEF008193
A range, from and to, in V
- 12
Single-phase under voltage possibleEF003390
Yes or no
YesNo - 13
Three-phase under voltage possibleEF003391
Yes or no
YesNo - 14
Single-phase overvoltage possibleEF003392
Yes or no
YesNo - 15
Three-phase overvoltage possibleEF003393
Yes or no
YesNo - 16
Single-phase hysteresis possibleEF003394
Yes or no
YesNo - 17
Three-phase hysteresis possibleEF003395
Yes or no
YesNo - 18
Contains function DC-under voltageEF003396
Yes or no
YesNo - 19
Contains function DC overvoltageEF003397
Yes or no
YesNo - 20
Contains function DC-voltage hysteresisEF003398
Yes or no
YesNo - 21
Min. adjustable delay-on energization timeEF008190
A number in s
- 22
Max. permitted delay-on energization timeEF008189
A number in s
- 23
Min. adjustable off-delay timeEF008192
A number in s
- 24
Max. permitted off-delay timeEF008191
A number in s
- 25
Number of contacts as normally closed contact (NC)EF008255
A number
- 26
Number of contacts as normally open contact (NO)EF008256
A number
- 27
Number of contacts as change-over contact (CO)EF008257
A number
- 28
Voltage type (operating voltage)EF005294
Choose one value
ACDCAC/DC - 29
Operating voltage AC 50 HzEF008206
A range, from and to, in V
- 30
Operating voltage AC 60 HzEF008207
A range, from and to, in V
- 31
Operating voltage DCEF008208
A range, from and to, in V
- 32
Rated switch currentEF006706
A number in A
- 33
WidthEF000008
A number in mm
- 34
HeightEF000040
A number in mm
- 35
DepthEF000049
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.