Current monitoring relay EC001440

A relay that detects and responds to variations in electrical current.

Features 38

  1. 1

    Type of electric connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew ConnectionWelding connectionPlug-in connection
  2. 2

    Tightening torqueEF005520

    A range, from and to, in Nm

  3. 3

    With detachable clampsEF003340

    Yes or no

    YesNo
  4. 4

    External power supply requiredEF003292

    Yes or no

    YesNo
  5. 5

    Voltage type of supply voltageEF002991

    Choose one value

    ACDCAC/DC
  6. 6

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  7. 7

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  8. 8

    Supply voltage DCEF007534

    A range, from and to, in V

  9. 9

    Voltage measurement rangeEF002486

    A range, from and to, in V

  10. 10

    Current type (no longer used)EF000143

    Choose one value

    ACDCAC/DC
  11. 11

    Current measurement rangeEF000417

    A range, from and to, in A

  12. 12

    Response value amperage 1EF008204

    A range, from and to, in A

  13. 13

    Response value amperage 2EF008205

    A range, from and to, in A

  14. 14

    Single-phase under current possibleEF003405

    Yes or no

    YesNo
  15. 15

    Three-phase under current possibleEF003406

    Yes or no

    YesNo
  16. 16

    Single-phase over current possibleEF003407

    Yes or no

    YesNo
  17. 17

    Three-phase over current possibleEF003408

    Yes or no

    YesNo
  18. 18

    Single-phase hysteresis possibleEF003394

    Yes or no

    YesNo
  19. 19

    Three-phase hysteresis possibleEF003395

    Yes or no

    YesNo
  20. 20

    Contains function DC-voltage under currentEF003409

    Yes or no

    YesNo
  21. 21

    Contains function DC-voltage over currentEF003410

    Yes or no

    YesNo
  22. 22

    Function DC-current hysteresisEF003411

    Yes or no

    YesNo
  23. 23

    Min. adjustable delay-on energization timeEF008190

    A number in s

  24. 24

    Max. permitted delay-on energization timeEF008189

    A number in s

  25. 25

    Min. adjustable off-delay timeEF008192

    A number in s

  26. 26

    Max. permitted off-delay timeEF008191

    A number in s

  27. 27

    Curent transformerEF001923

    Yes or no

    YesNo
  28. 28

    Number of contacts as normally closed contactEF008255

    A number

  29. 29

    Number of contacts as normally open contactEF008256

    A number

  30. 30

    Number of contacts as change-over contactEF008257

    A number

  31. 31

    Voltage type (operating voltage)EF005294

    Choose one value

    ACDCAC/DC
  32. 32

    Operating voltage at AC 50 HzEF008206

    A range, from and to, in V

  33. 33

    Operating voltage at AC 60 HzEF008207

    A range, from and to, in V

  34. 34

    Operating voltage at DCEF008208

    A range, from and to, in V

  35. 35

    Rated switch currentEF006706

    A number in A

  36. 36

    WidthEF000008

    A number in mm

  37. 37

    HeightEF000040

    A number in mm

  38. 38

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.