Two-hand control relay EC001452
A safety relay that ensures both hands are used to activate a machine.
Features 37
- 1
Type of electric connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew connectionWelding connectionWrapped connection - 2
Suitable for rail mountingEF003972
Yes or no
YesNo - 3
With detachable clampsEF003340
Yes or no
YesNo - 4
Voltage type (supply voltage)EF002991
Choose one value
ACDCAC/DC - 5
Supply voltage AC 50 HzEF007532
A range, from and to, in V
- 6
Supply voltage AC 60 HzEF007533
A range, from and to, in V
- 7
Supply voltage DCEF007534
A range, from and to, in V
- 8
Type of switch function of the inputsEF006969
Choose one value
Change-over contact (NO/NC)Normally closed contact and normally open contactNormally open contact (NO)Other - 9
With feedback circuitEF003343
Yes or no
YesNo - 10
With start inputEF003342
Yes or no
YesNo - 11
Type of control voltage 1EF002954
Choose one value
ACDCAC/DC - 12
Control voltage 1EF002952
A range, from and to, in V
- 13
Type of control voltage 2EF002955
Choose one value
ACDCAC/DC - 14
Control voltage 2EF002953
A range, from and to, in V
- 15
Number of outputs, safety related, undelayed, with contactEF003344
A number
- 16
Number of outputs, safety related, delayed, with contactEF003345
A number
- 17
Number of outputs, safety related, undelayed, semiconductorsEF003346
A number
- 18
Number of outputs, safety related, delayed, semiconductorsEF003347
A number
- 19
Number of outputs, signalling function, undelayed, with contactEF003348
A number
- 20
Number of outputs, signalling function, delayed, with contactEF003349
A number
- 21
Number of outputs, signalling function, undelayed, semiconductorsEF003350
A number
- 22
Number of outputs, signalling function, delayed, semiconductorsEF003351
A number
- 23
Voltage type (operating voltage)EF005294
Choose one value
ACDCAC/DC - 24
Operating voltage AC 50 HzEF008206
A range, from and to, in V
- 25
Operating voltage AC 60 HzEF008207
A range, from and to, in V
- 26
Operating voltage DCEF008208
A range, from and to, in V
- 27
Rated switch currentEF006706
A number in A
- 28
Suitable for safety functionsEF001597
Yes or no
YesNo - 29
Type class for safety demands according to EN 574EF003435
Choose one value
Type III AType III BType III C - 30
SIL according to IEC 61508EF009889
Choose one value
1234None - 31
Performance level according to EN ISO 13849-1EF007399
Choose one value
Level aLevel bLevel cLevel dLevel eNone - 32
With approval for BG BIAEF004145
Yes or no
YesNo - 33
With approval according to UL (no longer used)EF001783
Yes or no
YesNo - 34
WidthEF000008
A number in mm
- 35
HeightEF000040
A number in mm
- 36
DepthEF000049
A number in mm
- 37
With approval for TÜVEFDE0031
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.