Two-hand control relay EC001452

A safety relay that ensures both hands are used to activate a machine.

Features 37

  1. 1

    Type of electrical connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew connectionWelding connectionWrapped connection
  2. 2

    Suitable for rail mountingEF003972

    Yes or no

    YesNo
  3. 3

    With detachable clampsEF003340

    Yes or no

    YesNo
  4. 4

    Supply voltage typeEF002991

    Choose one value

    ACDCAC/DC
  5. 5

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  6. 6

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  7. 7

    Supply voltage DCEF007534

    A range, from and to, in V

  8. 8

    Type of switch function of the inputsEF006969

    Choose one value

    Change-over contact (NO/NC)Normally closed contact and normally open contactNormally open contact (NO)Other
  9. 9

    With feedback circuitEF003343

    Yes or no

    YesNo
  10. 10

    With start inputEF003342

    Yes or no

    YesNo
  11. 11

    Type of control voltage 1EF002954

    Choose one value

    ACDCAC/DC
  12. 12

    Control voltage 1EF002952

    A range, from and to, in V

  13. 13

    Type of control voltage 2EF002955

    Choose one value

    ACDCAC/DC
  14. 14

    Control voltage 2EF002953

    A range, from and to, in V

  15. 15

    Number of safety outputs, instantaneous contactEF003344

    A number

  16. 16

    Number of safety outputs, delayed contactEF003345

    A number

  17. 17

    Number of safety outputs, instantaneous semiconductorEF003346

    A number

  18. 18

    Number of safety outputs, delayed semiconductorsEF003347

    A number

  19. 19

    Number of signaling outputs, instantaneous contactEF003348

    A number

  20. 20

    Number of signaling outputs, delayed contactEF003349

    A number

  21. 21

    Number of signaling outputs, instantaneous semiconductorEF003350

    A number

  22. 22

    Number of delayed semiconductor signaling outputsEF003351

    A number

  23. 23

    Voltage type (operating voltage)EF005294

    Choose one value

    ACDCAC/DC
  24. 24

    Operating voltage at AC 50 HzEF008206

    A range, from and to, in V

  25. 25

    Operating voltage at AC 60 HzEF008207

    A range, from and to, in V

  26. 26

    Operating voltage at DCEF008208

    A range, from and to, in V

  27. 27

    Rated switch currentEF006706

    A number in A

  28. 28

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  29. 29

    Safety class in accordance with EN 574EF003435

    Choose one value

    Type III AType III BType III C
  30. 30

    SIL according to IEC 61508EF009889

    Choose one value

    1234None
  31. 31

    Performance level according to EN ISO 13849-1EF007399

    Choose one value

    Level aLevel bLevel cLevel dLevel eNone
  32. 32

    BG BIA certificateEF004145

    Yes or no

    YesNo
  33. 33

    WidthEF000008

    A number in mm

  34. 34

    HeightEF000040

    A number in mm

  35. 35

    DepthEF000049

    A number in mm

  36. 36

    With approval for TÜVEFDE0031

    Yes or no

    YesNo
  37. 37

    UL approvalEFNA0010

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.