Combined arrester for power supply systems EC001457

Published Earthing, lightning and surge protection EG000021

Features 32

  1. 1

    System configuration DCEF009926

    Yes or no

    YesNo
  2. 2

    System configuration ITEF009927

    Yes or no

    YesNo
  3. 3

    System configuration TNEF009928

    Yes or no

    YesNo
  4. 4

    System configuration TN-CEF009929

    Yes or no

    YesNo
  5. 5

    System configuration TN-C-SEF009933

    Yes or no

    YesNo
  6. 6

    System configuration TN-SEF009930

    Yes or no

    YesNo
  7. 7

    System configuration TTEF009931

    Yes or no

    YesNo
  8. 8

    System configuration otherEF009932

    Yes or no

    YesNo
  9. 9

    Number of PolesEF001391

    A number

  10. 10

    Lightning impulse current (10/350)EF000421

    A number in kA

  11. 11

    Max. voltage (Uc)EF004198

    A number in V

  12. 12

    Max. continuous voltage DCEF004777

    A number in V

  13. 13

    Nominal voltage ACEF004220

    A number in V

  14. 14

    Nominal voltage DCEF004221

    A number in V

  15. 15

    Max. PV-voltageEF008795

    A number in V

  16. 16

    Voltage protection levelEF003525

    A number in kV

  17. 17

    Voltage protection level L-NEF004236

    A number in kV

  18. 18

    Voltage protection level N-PEEF008796

    A number in kV

  19. 19

    Voltage protection level (DC+ - DC-)EF009643

    A number in kV

  20. 20

    Voltage protection level (DC+/DC- - PE)EF009644

    A number in kV

  21. 21

    Follow current extinguishing capability IfiEF004193

    A number in kA

  22. 22

    Specific energy (W/R)EF009797

    A number in kJ/Ohm

  23. 23

    Max. conductor cross section solid (solid, stranded)EF008827

    A number in mm²

  24. 24

    Max. conductor cross section flexible (fine-strand)EF008828

    A number in mm²

  25. 25

    Mounting MethodEF000003

    Choose one value

    On basic elementDirect mountingG-railDIN rail (top hat rail) 15 mmDIN rail (top hat rail) 35 mmNH00BusbarPre-mounted in housingOther
  26. 26

    Construction sizeEF002566

    Choose one value

    1 modular spacing2 modular spacing3 modular spacing4 modular spacing5 modular spacing6 modular spacing7 modular spacing8 modular spacing10 modular spacingOther
  27. 27

    Remote signallingEF004192

    Yes or no

    YesNo
  28. 28

    Signalling at the deviceEF004241

    Choose one value

    AcousticOpticAcoustic and opticNone
  29. 29

    Test classEF004228

    Choose one value

    Type 1Type 1 + 2
  30. 30

    ExhaustingEF004181

    Yes or no

    YesNo
  31. 31

    Integrated backup fuseEF008797

    Yes or no

    YesNo
  32. 32

    Energy-coordinated protection effect with regard to the terminal equipmentEF009798

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.