Kilowatt-hour meter EC001506

Features 32

  1. 1

    Type of meterEF005441

    Choose one value

    ElectromechanicalElectronic
  2. 2

    Nominal current (In)EF008873

    A number in A

  3. 3

    Max. current (Imax)EF000877

    A number in A

  4. 4

    Nominal voltage (Un) N-LEF008871

    A range, from and to, in V

  5. 5

    Nominal voltage (Un) L-LEF008872

    A range, from and to, in V

  6. 6

    FrequencyEF000416

    A range, from and to, in Hz

  7. 7

    Accuracy classEF008842

    Choose one value

    ABC
  8. 8

    Pole typeEF008843

    Choose one value

    Single phaseThree conductorFour conductorThree conductor/four conductor
  9. 9

    ModelEF000010

    Choose one value

    Direct measurementMeasurement transformer
  10. 10

    Energy typeEF007135

    Choose one value

    Effective powerReactive powerEffective power and reactive power
  11. 11

    Suitable forEF000073

    Choose one value

    PurchasePurchase/supply
  12. 12

    Tariff typeEF007550

    Choose one value

    One-tariffTwo-tariffMulti-tariff
  13. 13

    Tariff controlEF008834

    Choose one value

    InternalExternalInternal/external
  14. 14

    Measurement type load profileEF008844

    Yes or no

    YesNo
  15. 15

    Escapement mechanismEF008835

    Yes or no

    YesNo
  16. 16

    CalibratedEF008836

    Yes or no

    YesNo
  17. 17

    ApprovalEF008837

    Choose one value

    Measuring Instruments DirectiveDomestic
  18. 18

    Pulse outputEF008838

    Choose one value

    NoneOpticalElectrical
  19. 19

    Pulse typeEF008839

    Choose one value

    S0D0
  20. 20

    Pulse rateEF008840

    A range, from and to, in Imp/kWh (kvarh)

  21. 21

    Type of indicationEF000306

    Choose one value

    AnalogDigitalNone
  22. 22

    Mounting methodEF000003

    Choose one value

    Surface mountingBuilt-inFront mountingDIN rail adapter (DRA)Plug-in techniqueIntermediate plug
  23. 23

    Width expressed in the number of modulesEF002950

    A number

  24. 24

    WidthEF000008

    A number in mm

  25. 25

    DepthEF000049

    A number in mm

  26. 26

    HeightEF000040

    A number in mm

  27. 27

    Type of interfaceEF006977

    Choose one value

    EN 62056-21KNXLON busM-bus (wired)ModbusRS-485OtherNone
  28. 28

    EEC40 signatureEF008845

    Yes or no

    YesNo
  29. 29

    With lock codeEF008846

    Yes or no

    YesNo
  30. 30

    Number of positions total (counter)EF004442

    A number

  31. 31

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  32. 32

    Degree of protection (NEMA)EF011959

    Choose one value

    1233R44XOther

Codes after each name are ETIM feature codes. Use them, not the names, in product data.