Fieldbus, decentr. periphery - analogue I/O module EC001596
Features 77
- 1
Supply voltage AC 50 HzEF007532
A range, from and to, in V
- 2
Supply voltage AC 60 HzEF007533
A range, from and to, in V
- 3
Supply voltage DCEF007534
A range, from and to, in V
- 4
Voltage type (supply voltage)EF002991
Choose one value
ACAC/DCDC - 5
Input, currentEF003204
Yes or no
YesNo - 6
Input, voltageEF003205
Yes or no
YesNo - 7
Input, resistorEF003206
Yes or no
YesNo - 8
Input, resistance thermometerEF003207
Yes or no
YesNo - 9
Input, thermocoupleEF003208
Yes or no
YesNo - 10
Input signal, configurableEF003209
Yes or no
YesNo - 11
Resolution of the analogue inputsEF003575
A number in bit
- 12
Output, currentEF003212
Yes or no
YesNo - 13
Output, voltageEF003213
Yes or no
YesNo - 14
Output signal configurableEF003214
Yes or no
YesNo - 15
Resolution of the analogue outputsEF003577
A number in bit
- 16
Number of analogue inputsEF001994
A number
- 17
Number of analogue outputsEF001995
A number
- 18
Analogue inputs configurableEF008518
Yes or no
YesNo - 19
Analogue outputs configurableEF008519
Yes or no
YesNo - 20
Number of HW-interfaces industrial EthernetEF003020
A number
- 21
Number of interfaces PROFINETEF006932
A number
- 22
Number of HW-interfaces RS-232EF003021
A number
- 23
Number of HW-interfaces RS-422EF003022
A number
- 24
Number of HW-interfaces RS-485EF003023
A number
- 25
Number of HW-interfaces serial TTYEF003024
A number
- 26
Number of HW-interfaces parallelEF003026
A number
- 27
Number of HW-interfaces wirelessEF006933
A number
- 28
Number of HW-interfaces USBEF003025
A number
- 29
Number of HW-interfaces otherEF003027
A number
- 30
Supporting protocol for TCP/IPEF003050
Yes or no
YesNo - 31
Supporting protocol for PROFIBUSEF003052
Yes or no
YesNo - 32
Supporting protocol for CANEF003053
Yes or no
YesNo - 33
Supporting protocol for INTERBUSEF003054
Yes or no
YesNo - 34
Supporting protocol for ASIEF003051
Yes or no
YesNo - 35
Supporting protocol for KNXEF003055
Yes or no
YesNo - 36
Supporting protocol for ModbusEF003057
Yes or no
YesNo - 37
Supporting protocol for Data-HighwayEF003058
Yes or no
YesNo - 38
Supporting protocol for DeviceNetEF003059
Yes or no
YesNo - 39
Supporting protocol for SUCONETEF003060
Yes or no
YesNo - 40
Supporting protocol for LONEF003017
Yes or no
YesNo - 41
Supporting protocol for PROFINET IOEF007525
Yes or no
YesNo - 42
Supporting protocol for PROFINET CBAEF007524
Yes or no
YesNo - 43
Supporting protocol for SERCOSEF006657
Yes or no
YesNo - 44
Supporting protocol for Foundation FieldbusEF007522
Yes or no
YesNo - 45
Supporting protocol for EtherNet/IPEF007521
Yes or no
YesNo - 46
Supporting protocol for AS-Interface Safety at WorkEF007519
Yes or no
YesNo - 47
Supporting protocol for DeviceNet SafetyEF007520
Yes or no
YesNo - 48
Supporting protocol for INTERBUS-SafetyEF006662
Yes or no
YesNo - 49
Supporting protocol for PROFIsafeEF007526
Yes or no
YesNo - 50
Supporting protocol for SafetyBUS pEF007527
Yes or no
YesNo - 51
Supporting protocol for other bus systemsEF003062
Yes or no
YesNo - 52
Radio standard BluetoothEF007178
Yes or no
YesNo - 53
Radio standard WLAN 802.11EF007179
Yes or no
YesNo - 54
Mobile communication standard GPRSEF008523
Yes or no
YesNo - 55
Mobile communication standard 2G (GSM)EF008524
Yes or no
YesNo - 56
Mobile communication standard 3G (UMTS)EF008525
Yes or no
YesNo - 57
IO link masterEF007298
Yes or no
YesNo - 58
System accessoryEF004118
Yes or no
YesNo - 59
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 60
Degree of protection (NEMA)EF011959
Choose one value
123R44X66P1213Other - 61
Type of electric connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew-/spring clamp connectionScrew connectionWelding connection - 62
Fieldbus connection over separate bus coupler possibleEF004002
Yes or no
YesNo - 63
Suitable for rail mountingEF003972
Yes or no
YesNo - 64
Wall mounting/direct mountingEF007020
Yes or no
YesNo - 65
Front built-in possibleEF007016
Yes or no
YesNo - 66
Rack-assembly possibleEF007018
Yes or no
YesNo - 67
Suitable for safety functionsEF001597
Yes or no
YesNo - 68
Category according to EN 954-1 (no longer used)EF006782
Choose one value
B1234 - 69
SIL according to IEC 61508EF009889
Choose one value
1234None - 70
Performance level according to EN ISO 13849-1EF007399
Choose one value
Level aLevel bLevel cLevel dLevel eNone - 71
Appendant operation agent (Ex ia)EF004141
Yes or no
YesNo - 72
Appendant operation agent (Ex ib)EF004142
Yes or no
YesNo - 73
Explosion safety category for gasEF003997
Choose one value
ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone - 74
Explosion safety category for dustEF003998
Choose one value
ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone - 75
WidthEF000008
A number in mm
- 76
HeightEF000040
A number in mm
- 77
DepthEF000049
A number in mm