Fieldbus, decentr. periphery - analogue/digital I/O module EC001597

Features 89

  1. 1

    Number of analogue inputsEF001994

    A number

  2. 2

    Number of analogue outputsEF001995

    A number

  3. 3

    Analogue inputs configurableEF008518

    Yes or no

    YesNo
  4. 4

    Analogue outputs configurableEF008519

    Yes or no

    YesNo
  5. 5

    Number of digital inputsEF001992

    A number

  6. 6

    Number of digital outputsEF001993

    A number

  7. 7

    Digital inputs configurableEF008516

    Yes or no

    YesNo
  8. 8

    Digital outputs configurableEF008520

    Yes or no

    YesNo
  9. 9

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  10. 10

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  11. 11

    Supply voltage DCEF007534

    A range, from and to, in V

  12. 12

    Voltage type (supply voltage)EF002991

    Choose one value

    ACAC/DCDC
  13. 13

    Input current at signal 1EF001428

    A number in mA

  14. 14

    Permitted voltage at inputEF007554

    A range, from and to, in V

  15. 15

    Type of voltage (input voltage)EF003033

    Choose one value

    ACAC/DCDC
  16. 16

    Type of digital outputEF003601

    Choose one value

    RelayTransistorTriacOtherNone
  17. 17

    Output current at digital outputEF003218

    A number in A

  18. 18

    Output voltage at digital outputEF003215

    A range, from and to, in V

  19. 19

    Type of output voltageEF008222

    Choose one value

    ACAC/DCDC
  20. 20

    Short-circuit protection, digital outputs availableEF003320

    Yes or no

    YesNo
  21. 21

    Analogue input, currentEF003219

    Yes or no

    YesNo
  22. 22

    Analogue input, voltageEF003221

    Yes or no

    YesNo
  23. 23

    Analogue input, resistorEF003222

    Yes or no

    YesNo
  24. 24

    Analogue input, resistor temperatureEF003224

    Yes or no

    YesNo
  25. 25

    Analogue input, thermocoupleEF003225

    Yes or no

    YesNo
  26. 26

    Resolution of the analogue inputsEF003575

    A number in bit

  27. 27

    Analogue input signal configurableEF003227

    Yes or no

    YesNo
  28. 28

    Analogue output, currentEF003234

    Yes or no

    YesNo
  29. 29

    Analogue output, voltageEF003235

    Yes or no

    YesNo
  30. 30

    Resolution of the analogue outputsEF003577

    A number in bit

  31. 31

    Analogue output signal configurableEF003236

    Yes or no

    YesNo
  32. 32

    Number of HW-interfaces industrial EthernetEF003020

    A number

  33. 33

    Number of interfaces PROFINETEF006932

    A number

  34. 34

    Number of HW-interfaces RS-232EF003021

    A number

  35. 35

    Number of HW-interfaces RS-422EF003022

    A number

  36. 36

    Number of HW-interfaces RS-485EF003023

    A number

  37. 37

    Number of HW-interfaces serial TTYEF003024

    A number

  38. 38

    Number of HW-interfaces parallelEF003026

    A number

  39. 39

    Number of HW-interfaces wirelessEF006933

    A number

  40. 40

    Number of HW-interfaces USBEF003025

    A number

  41. 41

    Number of HW-interfaces otherEF003027

    A number

  42. 42

    With optical interfaceEF003028

    Yes or no

    YesNo
  43. 43

    Supporting protocol for TCP/IPEF003050

    Yes or no

    YesNo
  44. 44

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  45. 45

    Supporting protocol for CANEF003053

    Yes or no

    YesNo
  46. 46

    Supporting protocol for INTERBUSEF003054

    Yes or no

    YesNo
  47. 47

    Supporting protocol for ASIEF003051

    Yes or no

    YesNo
  48. 48

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  49. 49

    Supporting protocol for ModbusEF003057

    Yes or no

    YesNo
  50. 50

    Supporting protocol for Data-HighwayEF003058

    Yes or no

    YesNo
  51. 51

    Supporting protocol for DeviceNetEF003059

    Yes or no

    YesNo
  52. 52

    Supporting protocol for SUCONETEF003060

    Yes or no

    YesNo
  53. 53

    Supporting protocol for LONEF003017

    Yes or no

    YesNo
  54. 54

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  55. 55

    Supporting protocol for PROFINET CBAEF007524

    Yes or no

    YesNo
  56. 56

    Supporting protocol for SERCOSEF006657

    Yes or no

    YesNo
  57. 57

    Supporting protocol for Foundation FieldbusEF007522

    Yes or no

    YesNo
  58. 58

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  59. 59

    Supporting protocol for AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  60. 60

    Supporting protocol for DeviceNet SafetyEF007520

    Yes or no

    YesNo
  61. 61

    Supporting protocol for INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  62. 62

    Supporting protocol for PROFIsafeEF007526

    Yes or no

    YesNo
  63. 63

    Supporting protocol for SafetyBUS pEF007527

    Yes or no

    YesNo
  64. 64

    Supporting protocol for other bus systemsEF003062

    Yes or no

    YesNo
  65. 65

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  66. 66

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  67. 67

    Mobile communication standard GPRSEF008523

    Yes or no

    YesNo
  68. 68

    Mobile communication standard 2G (GSM)EF008524

    Yes or no

    YesNo
  69. 69

    Mobile communication standard 3G (UMTS)EF008525

    Yes or no

    YesNo
  70. 70

    IO link masterEF007298

    Yes or no

    YesNo
  71. 71

    System accessoryEF004118

    Yes or no

    YesNo
  72. 72

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  73. 73

    Type of electric connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew-/spring clamp connectionScrew connectionWelding connection
  74. 74

    Time delay at signal changeEF002382

    A range, from and to, in ms

  75. 75

    Fieldbus connection over separate bus coupler possibleEF004002

    Yes or no

    YesNo
  76. 76

    Suitable for rail mountingEF003972

    Yes or no

    YesNo
  77. 77

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  78. 78

    Front built-in possibleEF007016

    Yes or no

    YesNo
  79. 79

    Rack-assembly possibleEF007018

    Yes or no

    YesNo
  80. 80

    SIL according to IEC 61508EF009889

    Choose one value

    1234None
  81. 81

    Performance level according to EN ISO 13849-1EF007399

    Choose one value

    Level aLevel bLevel cLevel dLevel eNone
  82. 82

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  83. 83

    Appendant operation agent (Ex ia)EF004141

    Yes or no

    YesNo
  84. 84

    Appendant operation agent (Ex ib)EF004142

    Yes or no

    YesNo
  85. 85

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  86. 86

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  87. 87

    WidthEF000008

    A number in mm

  88. 88

    HeightEF000040

    A number in mm

  89. 89

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.