Fieldbus, decentr. periphery - analogue/digital I/O module EC001597
A device designed to facilitate communication and data exchange between peripheral components in a decentralized automation system. This module supports both analogue and digital input/output functions, allowing for the integration of various sensors and actuators within the network. It is specifically engineered to enhance the interoperability and flexibility of automation processes, enabling real-time monitoring and control. The module typically includes features for signal conversion, processing, and data transmission, making it essential for optimizing system performance in industrial environments. Its design caters to diverse operational requirements, ensuring compatibility with a wide range of devices and protocols in decentralized applications.
Features 102
- 1
Number of analogue inputsEF001994
A number
- 2
Number of analogue outputsEF001995
A number
- 3
Analogue inputs configurableEF008518
Yes or no
YesNo - 4
Analogue outputs configurableEF008519
Yes or no
YesNo - 5
Number of digital inputsEF001992
A number
- 6
Number of digital outputsEF001993
A number
- 7
Digital inputs configurableEF008516
Yes or no
YesNo - 8
Digital outputs configurableEF008520
Yes or no
YesNo - 9
Supply voltage AC 50 HzEF007532
A range, from and to, in V
- 10
Supply voltage AC 60 HzEF007533
A range, from and to, in V
- 11
Supply voltage DCEF007534
A range, from and to, in V
- 12
Supply voltage typeEF002991
Choose one value
ACAC/DCDC - 13
Input current for signal 1EF001428
A number in mA
- 14
Permitted voltage at inputEF007554
A range, from and to, in V
- 15
Type of voltage (input voltage)EF003033
Choose one value
ACAC/DCDC - 16
Type of digital outputEF003601
Choose one value
RelayTransistorTriacOtherNone - 17
Output current at digital outputEF003218
A number in A
- 18
Output voltage at digital outputEF003215
A range, from and to, in V
- 19
Type of output voltageEF008222
Choose one value
ACAC/DCDC - 20
Short-circuit protection, digital outputs availableEF003320
Yes or no
YesNo - 21
Analogue input, currentEF003219
Yes or no
YesNo - 22
Analogue input, voltageEF003221
Yes or no
YesNo - 23
Analogue input, resistorEF003222
Yes or no
YesNo - 24
Analogue input, resistor temperatureEF003224
Yes or no
YesNo - 25
Analogue input, thermocoupleEF003225
Yes or no
YesNo - 26
Resolution of the analogue inputsEF003575
A number in Bit
- 27
Analogue input signal configurableEF003227
Yes or no
YesNo - 28
Analogue output, currentEF003234
Yes or no
YesNo - 29
Analogue output, voltageEF003235
Yes or no
YesNo - 30
Resolution of the analogue outputsEF003577
A number in Bit
- 31
Analog output signal configurableEF003236
Yes or no
YesNo - 32
Number of Industrial Ethernet hardware connectorsEF003020
A number
- 33
Number of PROFINET interfacesEF006932
A number
- 34
Number of hardware RS-232 connectorsEF003021
A number
- 35
Number of hardware RS-422 connectorsEF003022
A number
- 36
The number of RS-485 hardware connectorsEF003023
A number
- 37
Number of TTY serial hardware connectorsEF003024
A number
- 38
Number of parallel hardware connectorsEF003026
A number
- 39
Number of wireless hardware interfacesEF006933
A number
- 40
The number of USB hardware connectorsEF003025
A number
- 41
Number of hardware connectors otherEF003027
A number
- 42
With optical interfaceEF003028
Yes or no
YesNo - 43
Supporting protocol for EtherCATEF017564
Yes or no
YesNo - 44
Supporting protocol for TCP/IPEF003050
Yes or no
YesNo - 45
Supporting protocol for PROFIBUSEF003052
Yes or no
YesNo - 46
Supporting protocol for CANEF003053
Yes or no
YesNo - 47
Supporting protocol for INTERBUSEF003054
Yes or no
YesNo - 48
Supporting protocol for ASIEF003051
Yes or no
YesNo - 49
Supporting protocol for KNXEF003055
Yes or no
YesNo - 50
Supporting protocol for ModbusEF003057
Yes or no
YesNo - 51
Supporting protocol for Data-HighwayEF003058
Yes or no
YesNo - 52
Supporting protocol for DeviceNetEF003059
Yes or no
YesNo - 53
Supporting protocol for SUCONETEF003060
Yes or no
YesNo - 54
Supporting protocol for LONEF003017
Yes or no
YesNo - 55
Supporting protocol for PROFINET IOEF007525
Yes or no
YesNo - 56
Supporting protocol for PROFINET CBAEF007524
Yes or no
YesNo - 57
Supporting protocol for SERCOSEF006657
Yes or no
YesNo - 58
Supporting protocol for Foundation FieldbusEF007522
Yes or no
YesNo - 59
Supporting protocol for EtherNet/IPEF007521
Yes or no
YesNo - 60
Supporting protocol for AS-Interface Safety at WorkEF007519
Yes or no
YesNo - 61
Supporting protocol for DeviceNet SafetyEF007520
Yes or no
YesNo - 62
Supporting protocol for INTERBUS-SafetyEF006662
Yes or no
YesNo - 63
Supporting protocol for PROFIsafeEF007526
Yes or no
YesNo - 64
Supporting protocol for SafetyBUS pEF007527
Yes or no
YesNo - 65
Supporting protocol for other bus systemsEF003062
Yes or no
YesNo - 66
Bluetooth wireless communication standardEF007178
Yes or no
YesNo - 67
Radio standard WLAN 802.11EF007179
Yes or no
YesNo - 68
Radio standard GPRSEF008523
Yes or no
YesNo - 69
Radio standard GSMEF008524
Yes or no
YesNo - 70
Mobile communications standard 3G (UMTS)EF008525
Yes or no
YesNo - 71
IO link masterEF007298
Yes or no
YesNo - 72
System accessoryEF004118
Yes or no
YesNo - 73
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 74
Type of electrical connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew / spring clamp connectionScrew connectionWelding connection - 75
Time delay at signal changeEF002382
A range, from and to, in ms
- 76
Fieldbus connection over separate bus coupler possibleEF004002
Yes or no
YesNo - 77
Suitable for rail mountingEF003972
Yes or no
YesNo - 78
Wall mounting/direct mountingEF007020
Yes or no
YesNo - 79
Panel mounting possibleEF007016
Yes or no
YesNo - 80
Rack-assembly possibleEF007018
Yes or no
YesNo - 81
SIL according to IEC 61508EF009889
Choose one value
1234None - 82
Performance level according to EN ISO 13849-1EF007399
Choose one value
Level aLevel bLevel cLevel dLevel eNone - 83
Suitable for safety functionsEF001597
Yes or no
YesNo - 84
Appendant operation agent (Ex ia)EF004141
Yes or no
YesNo - 85
Appendant operation agent (Ex ib)EF004142
Yes or no
YesNo - 86
Explosion safety category for gasEF003997
Choose one value
ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone - 87
Explosion safety category for dustEF003998
Choose one value
ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone - 88
WidthEF000008
A number in mm
- 89
HeightEF000040
A number in mm
- 90
DepthEF000049
A number in mm
- 91
Certified for UL hazardous location class IEFNA0014
Yes or no
YesNo - 92
Certified for UL hazardous location class IIEFNA0015
Yes or no
YesNo - 93
Certified for UL hazardous location division 1EFNA0016
Yes or no
YesNo - 94
Certified for UL hazardous location division 2EFNA0017
Yes or no
YesNo - 95
Certified for UL hazardous location class IIIEFNA0018
Yes or no
YesNo - 96
Certified for UL hazardous location group A (acetylene)EFNA0019
Yes or no
YesNo - 97
Certified for UL hazardous location group B (hydrogen)EFNA0020
Yes or no
YesNo - 98
Certified for UL hazardous location group C (ethylene)EFNA0021
Yes or no
YesNo - 99
Certified for UL hazardous location group D (propane)EFNA0022
Yes or no
YesNo - 100
Certified for UL hazardous location group E (metal dusts)EFNA0023
Yes or no
YesNo - 101
Certified for UL hazardous location group F (carbonaceous dusts)EFNA0024
Yes or no
YesNo - 102
Certified for UL hazardous location group G (non-conductive dusts)EFNA0025
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.