Fieldbus, decentr. periphery - power supply/segment module EC001600

A decentralized peripheral feed and segment module serves as a crucial component within automated systems, facilitating communication and control between various devices in a networked environment. This module is designed to manage the distribution of signals and data across multiple connected devices, ensuring efficient operation and connectivity. It plays a significant role in enhancing the functionality of decentralized systems, allowing for modular expansion and integration of additional components as needed. By supporting a variety of input and output configurations, this module enables seamless interaction between different technologies, contributing to the overall performance and reliability of the system. Its design emphasizes flexibility and adaptability, making it suitable for diverse applications in industrial automation and process control.

Features 78

  1. 1

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  2. 2

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  3. 3

    Supply voltage DCEF007534

    A range, from and to, in V

  4. 4

    Voltage type (supply voltage)EF002991

    Choose one value

    ACAC/DCDC
  5. 5

    Number of HW-interfaces industrial EthernetEF003020

    A number

  6. 6

    Number of interfaces PROFINETEF006932

    A number

  7. 7

    Number of HW-interfaces RS-232EF003021

    A number

  8. 8

    Number of HW-interfaces RS-422EF003022

    A number

  9. 9

    Number of HW-interfaces RS-485EF003023

    A number

  10. 10

    Number of HW-interfaces serial TTYEF003024

    A number

  11. 11

    Number of HW-interfaces parallelEF003026

    A number

  12. 12

    Number of HW-interfaces wirelessEF006933

    A number

  13. 13

    Number of HW-interfaces USBEF003025

    A number

  14. 14

    Number of HW-interfaces otherEF003027

    A number

  15. 15

    With optical interfaceEF003028

    Yes or no

    YesNo
  16. 16

    Supporting protocol for EtherCATEF017564

    Yes or no

    YesNo
  17. 17

    Supporting protocol for TCP/IPEF003050

    Yes or no

    YesNo
  18. 18

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  19. 19

    Supporting protocol for CANEF003053

    Yes or no

    YesNo
  20. 20

    Supporting protocol for INTERBUSEF003054

    Yes or no

    YesNo
  21. 21

    Supporting protocol for ASIEF003051

    Yes or no

    YesNo
  22. 22

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  23. 23

    Supporting protocol for ModbusEF003057

    Yes or no

    YesNo
  24. 24

    Supporting protocol for Data-HighwayEF003058

    Yes or no

    YesNo
  25. 25

    Supporting protocol for DeviceNetEF003059

    Yes or no

    YesNo
  26. 26

    Supporting protocol for SUCONETEF003060

    Yes or no

    YesNo
  27. 27

    Supporting protocol for LONEF003017

    Yes or no

    YesNo
  28. 28

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  29. 29

    Supporting protocol for PROFINET CBAEF007524

    Yes or no

    YesNo
  30. 30

    Supporting protocol for SERCOSEF006657

    Yes or no

    YesNo
  31. 31

    Supporting protocol for Foundation FieldbusEF007522

    Yes or no

    YesNo
  32. 32

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  33. 33

    Supporting protocol for AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  34. 34

    Supporting protocol for DeviceNet SafetyEF007520

    Yes or no

    YesNo
  35. 35

    Supporting protocol for INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  36. 36

    Supporting protocol for PROFIsafeEF007526

    Yes or no

    YesNo
  37. 37

    Supporting protocol for SafetyBUS pEF007527

    Yes or no

    YesNo
  38. 38

    Supporting protocol for other bus systemsEF003062

    Yes or no

    YesNo
  39. 39

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  40. 40

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  41. 41

    Mobile communication standard GPRSEF008523

    Yes or no

    YesNo
  42. 42

    Mobile communication standard 2G (GSM)EF008524

    Yes or no

    YesNo
  43. 43

    Mobile communication standard 3G (UMTS)EF008525

    Yes or no

    YesNo
  44. 44

    System accessoryEF004118

    Yes or no

    YesNo
  45. 45

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  46. 46

    Type of electric connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew-/spring clamp connectionScrew connectionWelding connection
  47. 47

    With potential separationEF003272

    Yes or no

    YesNo
  48. 48

    With power supply moduleEF003993

    Yes or no

    YesNo
  49. 49

    Suitable as segment moduleEF004104

    Yes or no

    YesNo
  50. 50

    Remote moduleEF006653

    Yes or no

    YesNo
  51. 51

    Fieldbus connection over separate bus coupler possibleEF004002

    Yes or no

    YesNo
  52. 52

    Bus diagnosis possibleEF003989

    Yes or no

    YesNo
  53. 53

    Suitable for rail mountingEF003972

    Yes or no

    YesNo
  54. 54

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  55. 55

    Front built-in possibleEF007016

    Yes or no

    YesNo
  56. 56

    Rack-assembly possibleEF007018

    Yes or no

    YesNo
  57. 57

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  58. 58

    SIL according to IEC 61508EF009889

    Choose one value

    1234None
  59. 59

    Performance level according to EN ISO 13849-1EF007399

    Choose one value

    Level aLevel bLevel cLevel dLevel eNone
  60. 60

    Appendant operation agent (Ex ia)EF004141

    Yes or no

    YesNo
  61. 61

    Appendant operation agent (Ex ib)EF004142

    Yes or no

    YesNo
  62. 62

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  63. 63

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  64. 64

    Certified for UL hazardous location class I (no longer used)EF017622

    Yes or no

    YesNo
  65. 65

    Certified for UL hazardous location class II (no longer used)EF017625

    Yes or no

    YesNo
  66. 66

    Certified for UL hazardous location class III (no longer used)EF017627

    Yes or no

    YesNo
  67. 67

    Certified for UL hazardous location division 1 (no longer used)EF017628

    Yes or no

    YesNo
  68. 68

    Certified for UL hazardous location division 2 (no longer used)EF017629

    Yes or no

    YesNo
  69. 69

    Certified for UL hazardous location group A (acetylene) (no longer used)EF017632

    Yes or no

    YesNo
  70. 70

    Certified for UL hazardous location group B (hydrogen) (no longer used)EF017633

    Yes or no

    YesNo
  71. 71

    Certified for UL hazardous location group C (ethylene) (no longer used)EF017635

    Yes or no

    YesNo
  72. 72

    Certified for UL hazardous location group D (propane) (no longer used)EF017636

    Yes or no

    YesNo
  73. 73

    Certified for UL hazardous location group E (metal dusts) (no longer used)EF017637

    Yes or no

    YesNo
  74. 74

    Certified for UL hazardous location group F (carbonaceous dusts) (no longer used)EF017638

    Yes or no

    YesNo
  75. 75

    Certified for UL hazardous location group G (non-conductive dusts) (no longer used)EF017639

    Yes or no

    YesNo
  76. 76

    WidthEF000008

    A number in mm

  77. 77

    HeightEF000040

    A number in mm

  78. 78

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.