Fieldbus, decentr. periphery - basic appliance EC001603
Features 103
- 1
With integrated power supplyEF003338
Yes or no
YesNo - 2
Input voltage AC 50 HzEF007118
A range, from and to, in V
- 3
Input voltage AC 60 HzEF007119
A range, from and to, in V
- 4
Input voltage DCEF007120
A range, from and to, in V
- 5
Type of voltage (input voltage)EF003033
Choose one value
ACAC/DCDC - 6
Max. input current AC 50 HzEF007360
A number in A
- 7
Max. input current AC 60 HzEF007361
A number in A
- 8
Max. input current DCEF007362
A number in A
- 9
Output voltage AC 50 HzEF006999
A range, from and to, in V
- 10
Output voltage AC 60 HzEF007000
A range, from and to, in V
- 11
Output voltage DCEF007001
A range, from and to, in V
- 12
Type of output voltageEF008222
Choose one value
ACAC/DCDC - 13
Max. output current AC 50 HzEF007351
A number in A
- 14
Max. output current AC 60 HzEF007352
A number in A
- 15
Max. output current DCEF007353
A number in A
- 16
Number of HW-interfaces industrial EthernetEF003020
A number
- 17
Number of interfaces PROFINETEF006932
A number
- 18
Number of HW-interfaces RS-232EF003021
A number
- 19
Number of HW-interfaces RS-422EF003022
A number
- 20
Number of HW-interfaces RS-485EF003023
A number
- 21
Number of HW-interfaces serial TTYEF003024
A number
- 22
Number of HW-interfaces USBEF003025
A number
- 23
Number of HW-interfaces parallelEF003026
A number
- 24
Number of HW-interfaces wirelessEF006933
A number
- 25
Number of HW-interfaces otherEF003027
A number
- 26
With optical interfaceEF003028
Yes or no
YesNo - 27
Supporting protocol in-bound for TCP/IPEF004091
Yes or no
YesNo - 28
Supporting protocol in-bound for PROFIBUSEF004088
Yes or no
YesNo - 29
Supporting protocol in-bound for CANEF004080
Yes or no
YesNo - 30
Supporting protocol in-bound for INTERBUSEF004084
Yes or no
YesNo - 31
Supporting protocol in-bound for ASIEF004079
Yes or no
YesNo - 32
Supporting protocol in-bound for KNXEF004083
Yes or no
YesNo - 33
Supporting protocol in-bound for ModbusEF004086
Yes or no
YesNo - 34
Supporting protocol in-bound for Data-highwayEF004081
Yes or no
YesNo - 35
Supporting protocol in-bound for DeviceNetEF004082
Yes or no
YesNo - 36
Supporting protocol in-bound for SUCONETEF004090
Yes or no
YesNo - 37
Supporting protocol in-bound for LONEF004085
Yes or no
YesNo - 38
Supporting protocol in-bound for SERCOSEF006659
Yes or no
YesNo - 39
Supporting protocol in-bound for PROFINET IOEF007433
Yes or no
YesNo - 40
Supporting protocol in-bound for PROFINET CBAEF007432
Yes or no
YesNo - 41
Supporting protocol in-bound for Foundation FieldbusEF007430
Yes or no
YesNo - 42
Supporting protocol in-bound for EtherNet/IPEF007429
Yes or no
YesNo - 43
Supporting protocol in-bound for AS-Interface Safety at WorkEF007427
Yes or no
YesNo - 44
Supporting protocol in-bound for DeviceNet SafetyEF007428
Yes or no
YesNo - 45
Supporting protocol in-bound for INTERBUS-SafetyEF006664
Yes or no
YesNo - 46
Supporting protocol in-bound for PROFIsafeEF007434
Yes or no
YesNo - 47
Supporting protocol in-bound for SafetyBUS pEF007435
Yes or no
YesNo - 48
Supporting protocol in-bound for other bus systemsEF004089
Yes or no
YesNo - 49
Supporting protocol out-bound for TCP/IPEF004078
Yes or no
YesNo - 50
Supporting protocol out-bound for PROFIBUSEF004075
Yes or no
YesNo - 51
Supporting protocol out-bound for CANEF004067
Yes or no
YesNo - 52
Supporting protocol out-bound for INTERBUSEF004071
Yes or no
YesNo - 53
Supporting protocol out-bound for ASIEF004066
Yes or no
YesNo - 54
Supporting protocol out-bound for KNXEF004070
Yes or no
YesNo - 55
Supporting protocol out-bound for ModbusEF004073
Yes or no
YesNo - 56
Supporting protocol out-bound for Data-highwayEF004068
Yes or no
YesNo - 57
Supporting protocol out-bound for DeviceNetEF004069
Yes or no
YesNo - 58
Supporting protocol out-bound for SUCONETEF004077
Yes or no
YesNo - 59
Supporting protocol out-bound for LONEF004072
Yes or no
YesNo - 60
Supporting protocol out-bound for SERCOSEF006661
Yes or no
YesNo - 61
Supporting protocol out-bound for PROFINET IOEF007424
Yes or no
YesNo - 62
Supporting protocol out-bound for PROFINET CBAEF007423
Yes or no
YesNo - 63
Supporting protocol out-bound for Foundation FieldbusEF007421
Yes or no
YesNo - 64
Supporting protocol out-bound for EtherNet/IPEF007420
Yes or no
YesNo - 65
Supporting protocol out-bound for AS-Interface Safety at WorkEF007418
Yes or no
YesNo - 66
Supporting protocol out-bound for DeviceNet SafetyEF007419
Yes or no
YesNo - 67
Supporting protocol out-bound for INTERBUS-SafetyEF006666
Yes or no
YesNo - 68
Supporting protocol out-bound for PROFIsafeEF007425
Yes or no
YesNo - 69
Supporting protocol out-bound for SafetyBUS pEF007426
Yes or no
YesNo - 70
Supporting protocol out-bound for other bus systemsEF004076
Yes or no
YesNo - 71
Radio standard BluetoothEF007178
Yes or no
YesNo - 72
Radio standard WLAN 802.11EF007179
Yes or no
YesNo - 73
IO link masterEF007298
Yes or no
YesNo - 74
System accessoryEF004118
Yes or no
YesNo - 75
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 76
Number of slotsEF003077
A number
- 77
With pluggable modules, digital I/OEF003078
Yes or no
YesNo - 78
With pluggable modules, analogue I/OEF003079
Yes or no
YesNo - 79
With pluggable modules, communication modulesEF003080
Yes or no
YesNo - 80
With pluggable modules, function and technology modulesEF003081
Yes or no
YesNo - 81
With pluggable modules, central modulesEF003082
Yes or no
YesNo - 82
With pluggable modules, othersEF003083
Yes or no
YesNo - 83
Type of electric connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew-/spring clamp connectionScrew connectionWelding connection - 84
With potential separationEF003272
Yes or no
YesNo - 85
Fieldbus connection over separate bus coupler possibleEF004002
Yes or no
YesNo - 86
With bus coupler for modular station connectionEF003990
Yes or no
YesNo - 87
Suitable for rail mountingEF003972
Yes or no
YesNo - 88
Wall mounting/direct mountingEF007020
Yes or no
YesNo - 89
Front built-in possibleEF007016
Yes or no
YesNo - 90
Rack-assembly possibleEF007018
Yes or no
YesNo - 91
Suitable for safety functionsEF001597
Yes or no
YesNo - 92
Safety class according to DIN V 19250EF003937
A number
- 93
Category according to EN 954-1 (no longer used)EF006782
Choose one value
B1234 - 94
SIL according to IEC 61508 (no longer used)EF004106
A number
- 95
SIL according to IEC 62061 (no longer used)EF007483
A number
- 96
Performance level according to EN ISO 13849-1EF007399
Choose one value
ABCDE - 97
Appendant operation agent (Ex ia)EF004141
Yes or no
YesNo - 98
Appendant operation agent (Ex ib)EF004142
Yes or no
YesNo - 99
Explosion safety category for gasEF003997
Choose one value
ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone - 100
Explosion safety category for dustEF003998
Choose one value
ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone - 101
WidthEF000008
A number in mm
- 102
HeightEF000040
A number in mm
- 103
DepthEF000049
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.