Fieldbus, decentr. periphery - basic appliance EC001603

Features 103

  1. 1

    With integrated power supplyEF003338

    Yes or no

    YesNo
  2. 2

    Input voltage at AC 50 HzEF007118

    A range, from and to, in V

  3. 3

    Input voltage at AC 60 HzEF007119

    A range, from and to, in V

  4. 4

    Input voltage at DCEF007120

    A range, from and to, in V

  5. 5

    Type of voltage (input voltage)EF003033

    Choose one value

    ACAC/DCDC
  6. 6

    Max. input current AC 50 HzEF007360

    A number in A

  7. 7

    Max. input current AC 60 HzEF007361

    A number in A

  8. 8

    Max. input current DCEF007362

    A number in A

  9. 9

    Output voltage at AC 50 HzEF006999

    A range, from and to, in V

  10. 10

    Output voltage at AC 60 HzEF007000

    A range, from and to, in V

  11. 11

    Output voltage at DCEF007001

    A range, from and to, in V

  12. 12

    Type of output voltageEF008222

    Choose one value

    ACAC/DCDC
  13. 13

    Max. output current AC 50 HzEF007351

    A number in A

  14. 14

    Max. output current AC 60 HzEF007352

    A number in A

  15. 15

    Max. output current DCEF007353

    A number in A

  16. 16

    Number of HW-interfaces industrial EthernetEF003020

    A number

  17. 17

    Number of HW-interfaces PROFINETEF006932

    A number

  18. 18

    Number of HW-interfaces RS-232EF003021

    A number

  19. 19

    Number of HW-interfaces RS-422EF003022

    A number

  20. 20

    Number of HW-interfaces RS-485EF003023

    A number

  21. 21

    Number of HW-interfaces serial TTYEF003024

    A number

  22. 22

    Number of HW-interfaces USBEF003025

    A number

  23. 23

    Number of HW-interfaces parallelEF003026

    A number

  24. 24

    Number of HW-interfaces WirelessEF006933

    A number

  25. 25

    Number of HW-interfaces otherEF003027

    A number

  26. 26

    With optical interfaceEF003028

    Yes or no

    YesNo
  27. 27

    Supporting protocol in-bound for TCP/IPEF004091

    Yes or no

    YesNo
  28. 28

    Supporting protocol in-bound for PROFIBUSEF004088

    Yes or no

    YesNo
  29. 29

    Supporting protocol in-bound for CANEF004080

    Yes or no

    YesNo
  30. 30

    Supporting protocol in-bound for INTERBUSEF004084

    Yes or no

    YesNo
  31. 31

    Supporting protocol in-bound for ASIEF004079

    Yes or no

    YesNo
  32. 32

    Supporting protocol in-bound for KNXEF004083

    Yes or no

    YesNo
  33. 33

    Supporting protocol in-bound for ModbusEF004086

    Yes or no

    YesNo
  34. 34

    Supporting protocol in-bound for Data-highwayEF004081

    Yes or no

    YesNo
  35. 35

    Supporting protocol in-bound for DeviceNetEF004082

    Yes or no

    YesNo
  36. 36

    Supporting protocol in-bound for SUCONETEF004090

    Yes or no

    YesNo
  37. 37

    Supporting protocol in-bound for LONEF004085

    Yes or no

    YesNo
  38. 38

    Supporting protocol in-bound for SERCOSEF006659

    Yes or no

    YesNo
  39. 39

    Supporting protocol in-bound for PROFINET IOEF007433

    Yes or no

    YesNo
  40. 40

    Supporting protocol in-bound for PROFINET CBAEF007432

    Yes or no

    YesNo
  41. 41

    Supporting protocol in-bound for Foundation FieldbusEF007430

    Yes or no

    YesNo
  42. 42

    Supporting protocol in-bound for EtherNet/IPEF007429

    Yes or no

    YesNo
  43. 43

    Supporting protocol in-bound for AS-Interface Safety at WorkEF007427

    Yes or no

    YesNo
  44. 44

    Supporting protocol in-bound for DeviceNet SafetyEF007428

    Yes or no

    YesNo
  45. 45

    Supporting protocol in-bound for INTERBUS-SafetyEF006664

    Yes or no

    YesNo
  46. 46

    Supporting protocol in-bound for PROFIsafeEF007434

    Yes or no

    YesNo
  47. 47

    Supporting protocol in-bound for SafetyBUS pEF007435

    Yes or no

    YesNo
  48. 48

    Supporting protocol in-bound for other bus systemsEF004089

    Yes or no

    YesNo
  49. 49

    Supporting protocol out-bound for TCP/IPEF004078

    Yes or no

    YesNo
  50. 50

    Supporting protocol out-bound for PROFIBUSEF004075

    Yes or no

    YesNo
  51. 51

    Supporting protocol out-bound for CANEF004067

    Yes or no

    YesNo
  52. 52

    Supporting protocol out-bound for INTERBUSEF004071

    Yes or no

    YesNo
  53. 53

    Supporting protocol out-bound for ASIEF004066

    Yes or no

    YesNo
  54. 54

    Supporting protocol out-bound for KNXEF004070

    Yes or no

    YesNo
  55. 55

    Supporting protocol out-bound for ModbusEF004073

    Yes or no

    YesNo
  56. 56

    Supporting protocol out-bound for Data-highwayEF004068

    Yes or no

    YesNo
  57. 57

    Supporting protocol out-bound for DeviceNetEF004069

    Yes or no

    YesNo
  58. 58

    Supporting protocol out-bound for SUCONETEF004077

    Yes or no

    YesNo
  59. 59

    Supporting protocol out-bound for LONEF004072

    Yes or no

    YesNo
  60. 60

    Supporting protocol out-bound for SERCOSEF006661

    Yes or no

    YesNo
  61. 61

    Supporting protocol out-bound for PROFINET IOEF007424

    Yes or no

    YesNo
  62. 62

    Supporting protocol out-bound for PROFINET CBAEF007423

    Yes or no

    YesNo
  63. 63

    Supporting protocol out-bound for Foundation FieldbusEF007421

    Yes or no

    YesNo
  64. 64

    Supporting protocol out-bound for EtherNet/IPEF007420

    Yes or no

    YesNo
  65. 65

    Supporting protocol out-bound for AS-Interface Safety at WorkEF007418

    Yes or no

    YesNo
  66. 66

    Supporting protocol out-bound for DeviceNet SafetyEF007419

    Yes or no

    YesNo
  67. 67

    Supporting protocol out-bound for INTERBUS-SafetyEF006666

    Yes or no

    YesNo
  68. 68

    Supporting protocol out-bound for PROFIsafeEF007425

    Yes or no

    YesNo
  69. 69

    Supporting protocol out-bound for SafetyBUS pEF007426

    Yes or no

    YesNo
  70. 70

    Supporting protocol out-bound for other bus systemsEF004076

    Yes or no

    YesNo
  71. 71

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  72. 72

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  73. 73

    IO link masterEF007298

    Yes or no

    YesNo
  74. 74

    System accessoryEF004118

    Yes or no

    YesNo
  75. 75

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  76. 76

    Number of slotsEF003077

    A number

  77. 77

    With pluggable modules, digital I/OEF003078

    Yes or no

    YesNo
  78. 78

    With pluggable modules, analogue I/OEF003079

    Yes or no

    YesNo
  79. 79

    With pluggable modules, communication modulesEF003080

    Yes or no

    YesNo
  80. 80

    With pluggable modules, function and technology modulesEF003081

    Yes or no

    YesNo
  81. 81

    With pluggable modules, central modulesEF003082

    Yes or no

    YesNo
  82. 82

    With pluggable modules, othersEF003083

    Yes or no

    YesNo
  83. 83

    Type of electric connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPCB connectionInsulation displacement connectionScrew-/spring clamp connectionScrew ConnectionWelding connection
  84. 84

    With potential separationEF003272

    Yes or no

    YesNo
  85. 85

    Fieldbus connection over separate bus coupler possibleEF004002

    Yes or no

    YesNo
  86. 86

    Bus coupler for modular station connection availableEF003990

    Yes or no

    YesNo
  87. 87

    Rail mounting possibleEF003972

    Yes or no

    YesNo
  88. 88

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  89. 89

    Front built-in possibleEF007016

    Yes or no

    YesNo
  90. 90

    Rack-assembly possibleEF007018

    Yes or no

    YesNo
  91. 91

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  92. 92

    Safety class according to DIN V 19250EF003937

    A number

  93. 93

    Category according to EN 954-1 (no longer used)EF006782

    Choose one value

    B1234
  94. 94

    SIL according to IEC 61508 (no longer used)EF004106

    A number

  95. 95

    SIL according to IEC 62061 (no longer used)EF007483

    A number

  96. 96

    Performance level acc. to EN ISO 13849-1EF007399

    Choose one value

    ABCDE
  97. 97

    Appendant operation agent (Ex ia)EF004141

    Yes or no

    YesNo
  98. 98

    Appendant operation agent (Ex ib)EF004142

    Yes or no

    YesNo
  99. 99

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  100. 100

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  101. 101

    WidthEF000008

    A number in mm

  102. 102

    HeightEF000040

    A number in mm

  103. 103

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.