Fieldbus, decentr. periphery - basic appliance EC001603

Features 81

  1. 1

    With integrated power supplyEF003338

    Yes or no

    YesNo
  2. 2

    Input voltage at AC 50 HzEF007118

    A range, from and to, in V

  3. 3

    Input voltage at AC 60 HzEF007119

    A range, from and to, in V

  4. 4

    Input voltage at DCEF007120

    A range, from and to, in V

  5. 5

    Type of voltage (input voltage)EF003033

    Choose one value

    ACAC/DCDC
  6. 6

    Max. input current AC 50 HzEF007360

    A number in A

  7. 7

    Max. input current AC 60 HzEF007361

    A number in A

  8. 8

    Max. input current DCEF007362

    A number in A

  9. 9

    Output voltage at AC 50 HzEF006999

    A range, from and to, in V

  10. 10

    Output voltage at AC 60 HzEF007000

    A range, from and to, in V

  11. 11

    Output voltage at DCEF007001

    A range, from and to, in V

  12. 12

    Type of output voltageEF008222

    Choose one value

    ACAC/DCDC
  13. 13

    Max. output current AC 50 HzEF007351

    A number in A

  14. 14

    Max. output current AC 60 HzEF007352

    A number in A

  15. 15

    Max. output current DCEF007353

    A number in A

  16. 16

    Number of Industrial Ethernet hardware connectorsEF003020

    A number

  17. 17

    Number of PROFINET interfacesEF006932

    A number

  18. 18

    Number of hardware RS-232 connectorsEF003021

    A number

  19. 19

    Number of hardware RS-422 connectorsEF003022

    A number

  20. 20

    The number of RS-485 hardware connectorsEF003023

    A number

  21. 21

    Number of TTY serial hardware connectorsEF003024

    A number

  22. 22

    The number of USB hardware connectorsEF003025

    A number

  23. 23

    Number of parallel hardware connectorsEF003026

    A number

  24. 24

    Number of wireless hardware interfacesEF006933

    A number

  25. 25

    Number of hardware connectors otherEF003027

    A number

  26. 26

    With optical interfaceEF003028

    Yes or no

    YesNo
  27. 27

    Supporting protocol for TCP/IPEF003050

    Yes or no

    YesNo
  28. 28

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  29. 29

    Supporting protocol for CANEF003053

    Yes or no

    YesNo
  30. 30

    Supporting protocol for INTERBUSEF003054

    Yes or no

    YesNo
  31. 31

    Supporting protocol for ASIEF003051

    Yes or no

    YesNo
  32. 32

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  33. 33

    Supporting protocol for ModbusEF003057

    Yes or no

    YesNo
  34. 34

    Supporting protocol for Data-HighwayEF003058

    Yes or no

    YesNo
  35. 35

    Supporting protocol for DeviceNetEF003059

    Yes or no

    YesNo
  36. 36

    Supporting protocol for SUCONETEF003060

    Yes or no

    YesNo
  37. 37

    Supporting protocol for LONEF003017

    Yes or no

    YesNo
  38. 38

    Supporting protocol for SERCOSEF006657

    Yes or no

    YesNo
  39. 39

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  40. 40

    Supporting protocol for PROFINET CBAEF007524

    Yes or no

    YesNo
  41. 41

    Supporting protocol for Foundation FieldbusEF007522

    Yes or no

    YesNo
  42. 42

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  43. 43

    Supporting protocol for AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  44. 44

    Supporting protocol for DeviceNet SafetyEF007520

    Yes or no

    YesNo
  45. 45

    Supporting protocol for INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  46. 46

    Supporting protocol for PROFIsafeEF007526

    Yes or no

    YesNo
  47. 47

    Supporting protocol for SafetyBUS pEF007527

    Yes or no

    YesNo
  48. 48

    Supporting protocol for other bus systemsEF003062

    Yes or no

    YesNo
  49. 49

    Bluetooth wireless communication standardEF007178

    Yes or no

    YesNo
  50. 50

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  51. 51

    Radio standard GPRSEF008523

    Yes or no

    YesNo
  52. 52

    Radio standard GSMEF008524

    Yes or no

    YesNo
  53. 53

    Mobile communications standard 3G (UMTS)EF008525

    Yes or no

    YesNo
  54. 54

    IO link masterEF007298

    Yes or no

    YesNo
  55. 55

    System accessoryEF004118

    Yes or no

    YesNo
  56. 56

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  57. 57

    Number of slotsEF003077

    A number

  58. 58

    With pluggable modules, digital I/OEF003078

    Yes or no

    YesNo
  59. 59

    With pluggable modules, analogue I/OEF003079

    Yes or no

    YesNo
  60. 60

    With pluggable modules, communication modulesEF003080

    Yes or no

    YesNo
  61. 61

    With pluggable modules, function and technology modulesEF003081

    Yes or no

    YesNo
  62. 62

    With pluggable modules, central modulesEF003082

    Yes or no

    YesNo
  63. 63

    With pluggable modules, othersEF003083

    Yes or no

    YesNo
  64. 64

    Type of electrical connectionEF003961

    Choose one value

    Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew / spring clamp connectionScrew connectionWelding connection
  65. 65

    With potential separationEF003272

    Yes or no

    YesNo
  66. 66

    Fieldbus connection over separate bus coupler possibleEF004002

    Yes or no

    YesNo
  67. 67

    With bus coupler for modular station connectionEF003990

    Yes or no

    YesNo
  68. 68

    Suitable for rail mountingEF003972

    Yes or no

    YesNo
  69. 69

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  70. 70

    Panel mounting possibleEF007016

    Yes or no

    YesNo
  71. 71

    Rack-assembly possibleEF007018

    Yes or no

    YesNo
  72. 72

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  73. 73

    SIL according to IEC 61508EF009889

    Choose one value

    1234None
  74. 74

    Performance level according to EN ISO 13849-1EF007399

    Choose one value

    Level aLevel bLevel cLevel dLevel eNone
  75. 75

    Appendant operation agent (Ex ia)EF004141

    Yes or no

    YesNo
  76. 76

    Appendant operation agent (Ex ib)EF004142

    Yes or no

    YesNo
  77. 77

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  78. 78

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  79. 79

    WidthEF000008

    A number in mm

  80. 80

    HeightEF000040

    A number in mm

  81. 81

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.