Fieldbus, decentr. periphery - communication module EC001604

Features 51

  1. 1

    Supply voltage AC 50 HzEF007532

    A range, from and to, in V

  2. 2

    Supply voltage AC 60 HzEF007533

    A range, from and to, in V

  3. 3

    Supply voltage DCEF007534

    A range, from and to, in V

  4. 4

    Voltage type of supply voltageEF002991

    Choose one value

    ACAC/DCDC
  5. 5

    Supporting protocol for TCP/IPEF003050

    Yes or no

    YesNo
  6. 6

    Supporting protocol for PROFIBUSEF003052

    Yes or no

    YesNo
  7. 7

    Supporting protocol for CANEF003053

    Yes or no

    YesNo
  8. 8

    Supporting protocol for INTERBUSEF003054

    Yes or no

    YesNo
  9. 9

    Supporting protocol for ASIEF003051

    Yes or no

    YesNo
  10. 10

    Supporting protocol for KNXEF003055

    Yes or no

    YesNo
  11. 11

    Supporting Protocol for ModbusEF003057

    Yes or no

    YesNo
  12. 12

    Supporting protocol for Data-HighwayEF003058

    Yes or no

    YesNo
  13. 13

    Supporting protocol for DeviceNetEF003059

    Yes or no

    YesNo
  14. 14

    Supporting protocol for SUCONETEF003060

    Yes or no

    YesNo
  15. 15

    Supporting protocol for LONEF003017

    Yes or no

    YesNo
  16. 16

    Supporting protocol for SERCOSEF006657

    Yes or no

    YesNo
  17. 17

    Supporting protocol for PROFINET IOEF007525

    Yes or no

    YesNo
  18. 18

    Supporting protocol for PROFINET CBAEF007524

    Yes or no

    YesNo
  19. 19

    Supporting protocol for Foundation FieldbusEF007522

    Yes or no

    YesNo
  20. 20

    Supporting protocol for EtherNet/IPEF007521

    Yes or no

    YesNo
  21. 21

    Supporting protocol for AS-Interface Safety at WorkEF007519

    Yes or no

    YesNo
  22. 22

    Supporting protocol for DeviceNet SafetyEF007520

    Yes or no

    YesNo
  23. 23

    Supporting protocol for INTERBUS-SafetyEF006662

    Yes or no

    YesNo
  24. 24

    Supporting protocol for PROFIsafeEF007526

    Yes or no

    YesNo
  25. 25

    Supporting protocol for SafetyBUS pEF007527

    Yes or no

    YesNo
  26. 26

    Supporting protocol for other bus systemsEF003062

    Yes or no

    YesNo
  27. 27

    Radio standard BluetoothEF007178

    Yes or no

    YesNo
  28. 28

    Radio standard WLAN 802.11EF007179

    Yes or no

    YesNo
  29. 29

    Radio standard GPRSEF008523

    Yes or no

    YesNo
  30. 30

    Radio standard GSMEF008524

    Yes or no

    YesNo
  31. 31

    Radio standard UMTSEF008525

    Yes or no

    YesNo
  32. 32

    IO link masterEF007298

    Yes or no

    YesNo
  33. 33

    System accessoryEF004118

    Yes or no

    YesNo
  34. 34

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  35. 35

    With potential separationEF003272

    Yes or no

    YesNo
  36. 36

    Fieldbus connection over separate bus coupler possibleEF004002

    Yes or no

    YesNo
  37. 37

    Rail mounting possibleEF003972

    Yes or no

    YesNo
  38. 38

    Wall mounting/direct mountingEF007020

    Yes or no

    YesNo
  39. 39

    Front built-in possibleEF007016

    Yes or no

    YesNo
  40. 40

    Rack-assembly possibleEF007018

    Yes or no

    YesNo
  41. 41

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  42. 42

    Category according to EN 954-1 (no longer used)EF006782

    Choose one value

    B1234
  43. 43

    SIL according to IEC 61508EF009889

    Choose one value

    1234None
  44. 44

    Performance level acc. to EN ISO 13849-1EF007399

    Choose one value

    Level aLevel bLevel cLevel dLevel eNone
  45. 45

    Appendant operation agent (Ex ia)EF004141

    Yes or no

    YesNo
  46. 46

    Appendant operation agent (Ex ib)EF004142

    Yes or no

    YesNo
  47. 47

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  48. 48

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  49. 49

    WidthEF000008

    A number in mm

  50. 50

    HeightEF000040

    A number in mm

  51. 51

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.