Feldbus, Dez. Peripherie - Kommunikations-Modul EC001604
A communications module designed for decentralized peripheral systems within a field bus architecture facilitates data exchange and control between various networked devices. This module is integral to enabling communication protocols, allowing for the seamless transfer of information among connected components. It typically supports multiple communication standards, enhancing interoperability and flexibility in industrial automation environments. The communications module is characterized by its ability to integrate diverse devices, manage communication traffic, and ensure reliable data transmission, ultimately contributing to efficient system performance and operational reliability in complex setups.
Features 76
- 1
Versorgungsspannung AC 50 HzEF007532
A range, from and to, in V
- 2
Versorgungsspannung AC 60 HzEF007533
A range, from and to, in V
- 3
Versorgungsspannung DCEF007534
A range, from and to, in V
- 4
Spannungsart der VersorgungsspannungEF002991
Choose one value
ACAC/DCDC - 5
Anzahl der HW-Schnittstellen CANEF017563
A number
- 6
Anzahl der HW-Schnittstellen Industrial EthernetEF003020
A number
- 7
Anzahl der Schnittstellen PROFINETEF006932
A number
- 8
Anzahl der HW-Schnittstellen seriell RS-232EF003021
A number
- 9
Anzahl der HW-Schnittstellen seriell RS-422EF003022
A number
- 10
Anzahl der HW-Schnittstellen seriell RS-485EF003023
A number
- 11
Anzahl der HW-Schnittstellen seriell TTYEF003024
A number
- 12
Anzahl der HW-Schnittstellen USBEF003025
A number
- 13
Anzahl der HW-Schnittstellen parallelEF003026
A number
- 14
Anzahl der HW-Schnittstellen WirelessEF006933
A number
- 15
Anzahl der HW-Schnittstellen sonstigeEF003027
A number
- 16
Unterstützt Protokoll für EtherCATEF017564
Yes or no
YesNo - 17
Unterstützt Protokoll für TCP/IPEF003050
Yes or no
YesNo - 18
Unterstützt Protokoll für PROFIBUSEF003052
Yes or no
YesNo - 19
Unterstützt Protokoll für CANEF003053
Yes or no
YesNo - 20
Unterstützt Protokoll für INTERBUSEF003054
Yes or no
YesNo - 21
Unterstützt Protokoll für ASIEF003051
Yes or no
YesNo - 22
Unterstützt Protokoll für KNXEF003055
Yes or no
YesNo - 23
Unterstützt Protokoll für ModbusEF003057
Yes or no
YesNo - 24
Unterstützt Protokoll für Data-HighwayEF003058
Yes or no
YesNo - 25
Unterstützt Protokoll für DeviceNetEF003059
Yes or no
YesNo - 26
Unterstützt Protokoll für SUCONETEF003060
Yes or no
YesNo - 27
Unterstützt Protokoll für LONEF003017
Yes or no
YesNo - 28
Unterstützt Protokoll für SERCOSEF006657
Yes or no
YesNo - 29
Unterstützt Protokoll für PROFINET IOEF007525
Yes or no
YesNo - 30
Unterstützt Protokoll für PROFINET CBAEF007524
Yes or no
YesNo - 31
Unterstützt Protokoll für Foundation FieldbusEF007522
Yes or no
YesNo - 32
Unterstützt Protokoll für EtherNet/IPEF007521
Yes or no
YesNo - 33
Unterstützt Protokoll für AS-Interface Safety at WorkEF007519
Yes or no
YesNo - 34
Unterstützt Protokoll für DeviceNet SafetyEF007520
Yes or no
YesNo - 35
Unterstützt Protokoll für INTERBUS-SafetyEF006662
Yes or no
YesNo - 36
Unterstützt Protokoll für PROFIsafeEF007526
Yes or no
YesNo - 37
Unterstützt Protokoll für SafetyBUS pEF007527
Yes or no
YesNo - 38
Unterstützt Protokoll für sonstige BussystemeEF003062
Yes or no
YesNo - 39
Funkstandard BluetoothEF007178
Yes or no
YesNo - 40
Funkstandard WLAN 802.11EF007179
Yes or no
YesNo - 41
Mobilfunkstandard GPRSEF008523
Yes or no
YesNo - 42
Funkstandard eGPRSEF009703
Yes or no
YesNo - 43
Mobilfunkstandard 2G (GSM)EF008524
Yes or no
YesNo - 44
Funkstandard LTEEF009709
Yes or no
YesNo - 45
Mobilfunkstandard 3G (UMTS)EF008525
Yes or no
YesNo - 46
IO-Link MasterEF007298
Yes or no
YesNo - 47
SystemkomponenteEF004118
Yes or no
YesNo - 48
Schutzart (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 49
Mit PotentialtrennungEF003272
Yes or no
YesNo - 50
Feldbusanschluss über seperaten Buskoppler möglichEF004002
Yes or no
YesNo - 51
Geeignet für TragschienenmontageEF003972
Yes or no
YesNo - 52
Wand-/Direktmontage möglichEF007020
Yes or no
YesNo - 53
Fronteinbau möglichEF007016
Yes or no
YesNo - 54
Rack-Montage möglichEF007018
Yes or no
YesNo - 55
Geeignet für SicherheitsfunktionenEF001597
Yes or no
YesNo - 56
SIL nach IEC 61508EF009889
Choose one value
1234ohne - 57
Performance Level nach EN ISO 13849-1EF007399
Choose one value
Level aLevel bLevel cLevel dLevel eohne - 58
Zugehöriges Betriebsmittel (Ex ia)EF004141
Yes or no
YesNo - 59
Zugehöriges Betriebsmittel (Ex ib)EF004142
Yes or no
YesNo - 60
Explosionsschutz-Kategorie für GasEF003997
Choose one value
ATEX Gas-Ex-Schutz, Kat. 1GATEX Gas-Ex-Schutz, Kat. 2GATEX Gas-Ex-Schutz, Kat. 3Gsonstigeohne - 61
Explosionsschutz-Kategorie für StaubEF003998
Choose one value
ATEX Staub-Ex-Schutz, Kat. 1DATEX Staub-Ex-Schutz, Kat. 2DATEX Staub-Ex-Schutz, Kat. 3Dsonstigeohne - 62
Zertifiziert für UL-Gefahrenbereich Klasse I (no longer used)EF017622
Yes or no
YesNo - 63
Zertifiziert für UL-Gefahrenbereich Klasse II (no longer used)EF017625
Yes or no
YesNo - 64
Zertifiziert für UL-Gefahrenbereich Klasse III (no longer used)EF017627
Yes or no
YesNo - 65
Zertifiziert für UL-Gefahrenbereich Division 1 (no longer used)EF017628
Yes or no
YesNo - 66
Zertifiziert für UL-Gefahrenbereich Division 2 (no longer used)EF017629
Yes or no
YesNo - 67
Zertifiziert für UL-Gefahrenbereich Gruppe A (Acetylen) (no longer used)EF017632
Yes or no
YesNo - 68
Zertifiziert für UL-Gefahrenbereich Gruppe B (Wasserstoff) (no longer used)EF017633
Yes or no
YesNo - 69
Zertifiziert für UL-Gefahrenbereich Gruppe C (Ethylen) (no longer used)EF017635
Yes or no
YesNo - 70
Zertifiziert für UL-Gefahrenbereich Gruppe D (Propan) (no longer used)EF017636
Yes or no
YesNo - 71
Zertifiziert für UL-Gefahrenbereich Gruppe E (Metallstäube) (no longer used)EF017637
Yes or no
YesNo - 72
Zertifiziert für UL-Gefahrenbereich Gruppe F (kohlenstoffhaltige Stäube) (no longer used)EF017638
Yes or no
YesNo - 73
Zertifiziert für UL-Gefahrenbereich Gruppe G (nicht leitende Stäube) (no longer used)EF017639
Yes or no
YesNo - 74
BreiteEF000008
A number in mm
- 75
HöheEF000040
A number in mm
- 76
TiefeEF000049
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.