EC001605
Features 74
- 1
Supply voltage AC 50 HzEF007532
A range, from and to, in V
- 2
Supply voltage AC 60 HzEF007533
A range, from and to, in V
- 3
Supply voltage DCEF007534
A range, from and to, in V
- 4
Supply voltage typeEF002991
Choose one value
ACAC/DCDC - 5
Number of inputsEF000318
A number
- 6
Permitted voltage at inputEF007554
A range, from and to, in V
- 7
Type of voltage (input voltage)EF003033
Choose one value
ACAC/DCDC - 8
Type of digital outputEF003601
Choose one value
RelayTransistorTriacOtherNone - 9
Permitted voltage at outputEF007553
A range, from and to, in V
- 10
Type of output voltageEF008222
Choose one value
ACAC/DCDC - 11
Short-circuit protection, outputs availableEF003203
Yes or no
YesNo - 12
Number of motor outletsEF003949
A number
- 13
Rated operation current of the motorEF004055
A range, from and to, in A
- 14
With motor current parameter settingEF004056
Yes or no
YesNo - 15
Type of electrical connection at the motor outputEF003938
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew / spring clamp connectionScrew connectionWelding connection - 16
With brake outputEF003987
Yes or no
YesNo - 17
With thermal motor protectionEF004123
Yes or no
YesNo - 18
Number of Industrial Ethernet hardware connectorsEF003020
A number
- 19
Number of PROFINET interfacesEF006932
A number
- 20
Number of hardware RS-232 connectorsEF003021
A number
- 21
Number of hardware RS-422 connectorsEF003022
A number
- 22
The number of RS-485 hardware connectorsEF003023
A number
- 23
Number of TTY serial hardware connectorsEF003024
A number
- 24
The number of USB hardware connectorsEF003025
A number
- 25
Number of parallel hardware connectorsEF003026
A number
- 26
Number of wireless hardware interfacesEF006933
A number
- 27
Number of hardware connectors otherEF003027
A number
- 28
With optical interfaceEF003028
Yes or no
YesNo - 29
Supporting protocol for TCP/IPEF003050
Yes or no
YesNo - 30
Supporting protocol for PROFIBUSEF003052
Yes or no
YesNo - 31
Supporting protocol for CANEF003053
Yes or no
YesNo - 32
Supporting protocol for INTERBUSEF003054
Yes or no
YesNo - 33
Supporting protocol for ASIEF003051
Yes or no
YesNo - 34
Supporting protocol for KNXEF003055
Yes or no
YesNo - 35
Supporting protocol for ModbusEF003057
Yes or no
YesNo - 36
Supporting protocol for Data-HighwayEF003058
Yes or no
YesNo - 37
Supporting protocol for DeviceNetEF003059
Yes or no
YesNo - 38
Supporting protocol for SUCONETEF003060
Yes or no
YesNo - 39
Supporting protocol for LONEF003017
Yes or no
YesNo - 40
Supporting protocol for PROFINET IOEF007525
Yes or no
YesNo - 41
Supporting protocol for PROFINET CBAEF007524
Yes or no
YesNo - 42
Supporting protocol for SERCOSEF006657
Yes or no
YesNo - 43
Supporting protocol for Foundation FieldbusEF007522
Yes or no
YesNo - 44
Supporting protocol for EtherNet/IPEF007521
Yes or no
YesNo - 45
Supporting protocol for AS-Interface Safety at WorkEF007519
Yes or no
YesNo - 46
Supporting protocol for DeviceNet SafetyEF007520
Yes or no
YesNo - 47
Supporting protocol for INTERBUS-SafetyEF006662
Yes or no
YesNo - 48
Supporting protocol for PROFIsafeEF007526
Yes or no
YesNo - 49
Supporting protocol for SafetyBUS pEF007527
Yes or no
YesNo - 50
Supporting protocol for other bus systemsEF003062
Yes or no
YesNo - 51
Bluetooth wireless communication standardEF007178
Yes or no
YesNo - 52
Radio standard WLAN 802.11EF007179
Yes or no
YesNo - 53
IO link masterEF007298
Yes or no
YesNo - 54
System accessoryEF004118
Yes or no
YesNo - 55
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 56
Type of electrical connectionEF003961
Choose one value
Insulation piercing connectionSpring clamp connectionFlat plug-in connectionClip connectionSoldering flag connectionPrinted circuit board (PCB) connectionInsulation displacement connectionScrew / spring clamp connectionScrew connectionWelding connection - 57
Fieldbus connection over separate bus coupler possibleEF004002
Yes or no
YesNo - 58
Suitable for rail mountingEF003972
Yes or no
YesNo - 59
Wall mounting/direct mountingEF007020
Yes or no
YesNo - 60
Panel mounting possibleEF007016
Yes or no
YesNo - 61
Rack-assembly possibleEF007018
Yes or no
YesNo - 62
Suitable for safety functionsEF001597
Yes or no
YesNo - 63
EF003937
A number
- 64
(no longer used)EF006782
Choose one value
B1234 - 65
(no longer used)EF004106
A number
- 66
(no longer used)EF007483
A number
- 67
Performance level according to EN ISO 13849-1EF007399
Choose one value
ABCDE - 68
Appendant operation agent (Ex ia)EF004141
Yes or no
YesNo - 69
Appendant operation agent (Ex ib)EF004142
Yes or no
YesNo - 70
Explosion safety category for gasEF003997
Choose one value
ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone - 71
Explosion safety category for dustEF003998
Choose one value
ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone - 72
WidthEF000008
A number in mm
- 73
HeightEF000040
A number in mm
- 74
DepthEF000049
A number in mm
Codes after each name are ETIM feature codes. Use them, not the names, in product data.