Central control system for buildings EC001670

Published Modular devices for distribution board/surface mounting EG000062

Features 37

  1. 1

    Mounting MethodEF000003

    Choose one value

    DIN railSurface mountedFlush mounted
  2. 2

    FunctionEF000030

    Choose one value

    Basic moduleExtension moduleDimmerRoller shutter-/Venetian shutter moduleSensor moduleClock moduleWeather sensorsWind sensor
  3. 3

    Central function OUTEF006713

    Yes or no

    YesNo
  4. 4

    Group switchEF004768

    Yes or no

    YesNo
  5. 5

    Panic functionEF005160

    Yes or no

    YesNo
  6. 6

    Presence simulationEF001213

    Yes or no

    YesNo
  7. 7

    Stair light and forewarnEF006715

    Yes or no

    YesNo
  8. 8

    Castor function, number of channelsEF006716

    A number

  9. 9

    Time rangeEF003384

    A range, from and to, in min

  10. 10

    Number of universal dim channelsEF006717

    A number

  11. 11

    Number of dimmer functionsEF004400

    A number

  12. 12

    Current surge function, number of channelsEF005325

    A number

  13. 13

    Roller shutter-/sun protection control, number of channelsEF006718

    A number

  14. 14

    Weekly programEF001184

    Yes or no

    YesNo
  15. 15

    Astro/solar programEF000224

    Yes or no

    YesNo
  16. 16

    Wind sensorEF006719

    A range, from and to, in m/s

  17. 17

    Rain sensorEF006720

    Yes or no

    YesNo
  18. 18

    Temperature sensorEF006721

    A range, from and to, in °C

  19. 19

    Brightness sensorEF006722

    A range, from and to, in lx

  20. 20

    Twilight sensorEF006723

    A range, from and to, in lx

  21. 21

    Number of channelsEF000259

    A number

  22. 22

    Module expansion up to max. number of channelsEF006724

    A number

  23. 23

    Contact typeEF001587

    Choose one value

    Normally open contact (no longer used)Change-over contact (no longer used)
  24. 24

    Control voltage 1EF002952

    A range, from and to, in V

  25. 25

    Type of control voltage 1EF002954

    Choose one value

    ACDCAC/DCOther
  26. 26

    Control voltage 2EF002953

    A range, from and to, in V

  27. 27

    Type of control voltage 2EF002955

    Choose one value

    ACDCAC/DCOther
  28. 28

    Rated currentEF000227

    A number in A

  29. 29

    Max. switching current (cos phi = 0.6)EF004920

    A number in A

  30. 30

    Dim capacity per channelEF004598

    A number in W

  31. 31

    Rated voltageEF003977

    A range, from and to, in V

  32. 32

    Rated frequencyEF001663

    A range, from and to, in Hz

  33. 33

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  34. 34

    Width in Number of Modular SpacingsEF002950

    A number

  35. 35

    WidthEF000008

    A number in mm

  36. 36

    HeightEF000040

    A number in mm

  37. 37

    DepthEF000049

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.