High bay luminaire EC001716

Features 37

  1. 1

    Lamp typeEF002423

    Choose one value

    Incandescent lamp (no longer used)Compact fluorescent lampHV halogen lampMetal halide lampHigh pressure sodium-vapour lampLow pressure sodium-vapour lampMercury vapour lampInduction lampOther
  2. 2

    Lamp holderEF000048

    Choose one value

    2G72G102G112G13B15dB22dBA9sE10E14E27
  3. 3

    Suitable for number of light sourcesEF006436

    A number

  4. 4

    Lamp powerEF000035

    A number in W

  5. 5

    Type of control gearEF000381

    Choose one value

    Conventional ballastLow-loss ballastElectronic ballast standardElectronic ballast 1-10 VElectronic ballast-DALIDigital electronic ballastElectronic ballast multiwatt 1-10 VElectronic ballast multiwatt DALINot required
  6. 6

    With control gearEF007556

    Yes or no

    YesNo
  7. 7

    IgniterEF004296

    Choose one value

    ConventionalDigitalWith breaking automaticNot required
  8. 8

    With igniterEF007557

    Yes or no

    YesNo
  9. 9

    CircuitEF000037

    Choose one value

    InductiveParallel-compensatedOther
  10. 10

    Suitable for emergency lightingEF004275

    Yes or no

    YesNo
  11. 11

    Nominal voltageEF005127

    A range, from and to, in V

  12. 12

    Direct-/indirect proportion separately controllableEF004264

    Yes or no

    YesNo
  13. 13

    Housing materialEF001596

    Choose one value

    AluminiumGlassPlasticStainless steelSteelOther
  14. 14

    Housing colourEF000136

    Choose one value

    AluminiumAnthraciteBeigeBlueBrownBronzeChromeStainless steelYellowGold
  15. 15

    Mounting methodEF000003

    Choose one value

    Surface mounting (no longer used)Built-inPendant
  16. 16

    With protective coverEF005500

    Yes or no

    YesNo
  17. 17

    Type of gridEF000282

    Choose one value

    WhiteMattHigh-glossPerforatedOther
  18. 18

    Material grid (no longer used)EF004288

    Choose one value

    SteelAluminiumPlasticOther
  19. 19

    Reflector materialEF004290

    Choose one value

    AluminiumGlassPlasticWithout reflector (no longer used)
  20. 20

    Light distributionEF004283

    Choose one value

    Narrow beam (no longer used)Wide beamMedium beam
  21. 21

    Light outletEF004282

    Choose one value

    DirectDirect/indirect
  22. 22

    Anti-glare limiting UGR lengthwiseEF004262

    A number

  23. 23

    Anti-glare limiting UGR crosswiseEF004263

    A number

  24. 24

    LengthEF001438

    A number in mm

  25. 25

    WidthEF000008

    A number in mm

  26. 26

    Height/depthEF001456

    A number in mm

  27. 27

    DiameterEF000551

    A number in mm

  28. 28

    Protection class according to IEC 61140EF000004

    Choose one value

    IIIIII
  29. 29

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  30. 30

    Impact strengthEF004293

    Choose one value

    IK01IK02IK03IK04IK05IK06IK07IK08IK09IK10None
  31. 31

    Ball-proof (no longer used)EF001263

    Yes or no

    YesNo
  32. 32

    Fire resistance "F" (no longer used)EF006421

    Yes or no

    YesNo
  33. 33

    Fire resistance "FF" (no longer used)EF006422

    Yes or no

    YesNo
  34. 34

    Luminaire with limited surface temperature, sign "D“ according to EN 60598-2-24EF006420

    Yes or no

    YesNo
  35. 35

    Extreme-temperatureEF004268

    A range, from and to, in °C

  36. 36

    Filament test according to IEC 695-2-1 (no longer used)EF004278

    Choose one value

    600 °C - 30 s650 °C - 5 s750 °C - 5 s850 °C - 5 s960 °C - 5 s
  37. 37

    With light sourceEF005905

    Yes or no

    YesNo

Codes after each name are ETIM feature codes. Use them, not the names, in product data.