Multiple beam light curtain EC001832
Multiple beam light barriers are active opto-electronic protective devices that use emitting and receiving elements to detect persons in a defined two-dimensional area. A series of parallel light beams transmitted from the sender to the receiver form a protective field that safeguards the hazardous area. Detection occurs when an opaque object fully interrupts one or more beams. The receiver signals the beam interruption by a signal change (OFF state) to its output signal switching devices (OSSDs). The signals of the OSSDs are used to stop the hazardous machine functions.
Features 34
- 1
Number of semiconductor outputs with signalling functionEF003945
A number
- 2
Number of contact energized outputs with signalling functionEF003946
A number
- 3
Number of protected semiconductor outputsEF003951
A number
- 4
Number of protected contact energized outputsEF003952
A number
- 5
Number of beamsEF003954
A number
- 6
ModelEF000010
Choose one value
Transmitter and receiver separatedTransmitter and receiver in one housing - 7
Type of interface for safety communicationEF003956
Choose one value
AS-Interface Safety at WorkDeviceNet SafetyPROFIsafeSafetyBUS pOther - 8
Type of electric connectionEF003961
Choose one value
Bus capCable axialCable with connectorCable radialClampAxial plugRadial plugConnector 1/2 inchConnector 3/4 inchConnector 7/8 inch - 9
Type of switching output of the OSSDEF003959
Choose one value
NPNNPN/NPNPNPPNP/NPNPNP/PNPRelay contactOther - 10
Detection capability for test bodiesEF003991
A number in mm
- 11
Scope of delivery of the one-way systemEF004032
Choose one value
ReceiverTransmitterTransmitter and receiver - 12
Max. output current at protected outputEF004035
A number in mA
- 13
Response timeEF004094
A number in ms
- 14
Transmission range of the safety fieldEF004098
A number in m
- 15
Switching voltage of OSSD at state "high"EF004102
A number in V
- 16
Voltage typeEF000187
Choose one value
ACAC/DCDCOther - 17
Beam spacingEF004113
A number in mm
- 18
Ambient temperatureEF002386
A range, from and to, in °C
- 19
Wavelength of the sensorEF004132
A number in nm
- 20
CascadableEF000507
Yes or no
YesNo - 21
With muting functionEF004057
Yes or no
YesNo - 22
With beam codingEF004114
Yes or no
YesNo - 23
With monitoring function downstream switching devicesEF004052
Yes or no
YesNo - 24
With restart blockageEF004054
Yes or no
YesNo - 25
Override possibleEF004061
Yes or no
YesNo - 26
Pre failure noticeEF004129
Yes or no
YesNo - 27
Condition analysis systemEF004130
Yes or no
YesNo - 28
WidthEF000008
A number in mm
- 29
HeightEF000040
A number in mm
- 30
LengthEF001438
A number in mm
- 31
Operation agent-safety classEF003982
Choose one value
Safety class 0Safety class 1Safety class 2Safety class 3 - 32
Explosion safety category for gasEF003997
Choose one value
ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone - 33
Explosion safety category for dustEF003998
Choose one value
ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone - 34
Type of safety according to IEC 61496-1EF004105
Choose one value
1234
Codes after each name are ETIM feature codes. Use them, not the names, in product data.