Ultrasonic single beam reflex light curtain EC001847

Features 27

  1. 1

    Type of electric connectionEF003961

    Choose one value

    Bus capInsulation piercing connectionSpring clamp connectionFlat plug-in connectionCableCable axialCable with connectorCable radialClip connectionClamp
  2. 2

    Type of switching outputEF003962

    Choose one value

    AS-InterfaceNAMURNPNNPN/NPNOptocouplerPNPPNP/NPNPNP/PNPRelay contactTwo-wire (no longer used)Other
  3. 3

    Type of switch functionEF003963

    Choose one value

    AnticoincidenceBreaker contact (NC)Programmable/configurableNormally open contact (NO)Change-over contact (NO/NC)Forced contact openingOther
  4. 4

    Blind zoneEF003986

    A number in mm

  5. 5

    Width sensorEF007094

    A number in mm

  6. 6

    Height of sensorEF007283

    A number in mm

  7. 7

    Length of sensorEF007334

    A number in mm

  8. 8

    Diameter sensorEF007111

    A number in mm

  9. 9

    Adjustable distanceEF008209

    A range, from and to, in mm

  10. 10

    Setting procedureEF003994

    Choose one value

    Manual adjustmentParameterizationTeach-InOther
  11. 11

    Measuring range lengthEF008213

    A range, from and to, in mm

  12. 12

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  13. 13

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  14. 14

    Construction type housingEF004008

    Choose one value

    ProfileCuboidSpecial construction (no longer used)RodCylinder plainCylinder, screw-thread
  15. 15

    Standard for interfacesEF004017

    Choose one value

    AnalogueAS-InterfaceBit parallelCANOpenDeviceNetEthernetINTERBUSPROFIBUSRS-232RS-422
  16. 16

    No load currentEF004028

    A number in mA

  17. 17

    Maximum output currentEF001315

    A number in mA

  18. 18

    Ambient temperatureEF002386

    A range, from and to, in °C

  19. 19

    Supply voltageEF004127

    A range, from and to, in V

  20. 20

    Relative repeat accuracyEF004100

    A number in %

  21. 21

    Switching frequencyEF003587

    A number in Hz

  22. 22

    Voltage typeEF000187

    Choose one value

    ACAC/DCDCOther
  23. 23

    Material active area of sensorEF004133

    Choose one value

    GlassCeramicsPlasticMetalPolytetrafluoroethylene (PTFE)Other
  24. 24

    Housing MaterialEF001596

    Choose one value

    AluminiumStainless SteelPlasticBrassPTE/FEPZincOther
  25. 25

    Material of cable sheathEF004136

    Choose one value

    Polyurethane (PUR)PUR vulcanizedPolyvinyl Chloride (PVC)SiliconeOther
  26. 26

    Synchronization possibleEF004117

    Yes or no

    YesNo
  27. 27

    AWG-numberEF007010

    A number

Codes after each name are ETIM feature codes. Use them, not the names, in product data.