Low voltage cable system EC001951

Features 27

  1. 1

    Wire materialEF006427

    Choose one value

    CopperOther
  2. 2

    Surface protection wireEF013603

    Choose one value

    GalvanizedTinnedOther
  3. 3

    Wire colourEF006428

    Choose one value

    ColourlessBlackWhiteOther
  4. 4

    Conductor cross sectionEF000085

    A number in mm²

  5. 5

    InsulatedEF000019

    Yes or no

    YesNo
  6. 6

    Number of light pointsEF007624

    A number

  7. 7

    With transformerEF000278

    Yes or no

    YesNo
  8. 8

    With mounting materialEF006009

    Yes or no

    YesNo
  9. 9

    Light source typeEF002423

    Choose one value

    HV halogen lampLED replaceableLED non-replaceableLV halogen lampOther
  10. 10

    Light source includedEF005905

    Yes or no

    YesNo
  11. 11

    Nominal voltageEF005127

    A range, from and to, in V

  12. 12

    Secondary voltageEF001470

    A number in V

  13. 13

    Maximum connection powerEF000232

    A number in W

  14. 14

    Control gearEF000381

    Choose one value

    Electronic transformerElectronic ballastConventional ballast/low-loss ballast inductiveConventional ballast/low-loss ballast compensatedLED driver constant voltageLED driver constant currentMagnetic transformerNot required
  15. 15

    Replaceable control gearEF016286

    Yes or no

    YesNo
  16. 16

    Energy efficiency class of integrated lampEF012487

    Choose one value

    A++, A+, A (LED)Other
  17. 17

    Energy efficiency class of the replaceable lamp suppliedEF012488

    Choose one value

    A++A+ABCDE
  18. 18

    Highest energy efficiency class of replaceable lampEF012489

    Choose one value

    A++A+ABCDE
  19. 19

    Lowest energy efficiency class of replaceable lampEF012490

    Choose one value

    A++A+ABCDE
  20. 20

    Rated life time L70/B50 at 25 °CEF011870

    A number in h

  21. 21

    Lumen maintenance at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015687

    A number in %

  22. 22

    Failure rate at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015691

    A number in %

  23. 23

    Constant luminous flux controlEF009482

    Yes or no

    YesNo
  24. 24

    Power factorEF025740

    A number

  25. 25

    Type of cablingEF011868

    Choose one value

    Suitable for through wiringThrough wiring includedEnding
  26. 26

    Number of PolesEF001391

    A number

  27. 27

    Connection TypeEF000124

    Choose one value

    CrimpingBlade terminalSolderInsulation Displacement ConnectorScrewed TerminalScrewless TerminalOther

Codes after each name are ETIM feature codes. Use them, not the names, in product data.