Low voltage cable Lighting system EC001951

An electrical system designed for distributing low-voltage power.

Features 25

  1. 1

    Material wireEF006427

    Choose one value

    CopperOther
  2. 2

    Surface protection wireEF013603

    Choose one value

    GalvanizedTinnedOther
  3. 3

    Wire colorEF006428

    Choose one value

    ColorlessBlackWhiteOther
  4. 4

    Conductor cross sectionEF000085

    A number in mm²

  5. 5

    InsulatedEF000019

    Yes or no

    YesNo
  6. 6

    Number of light headsEF007624

    A number

  7. 7

    With a transformerEF000278

    Yes or no

    YesNo
  8. 8

    With mounting materialEF006009

    Yes or no

    YesNo
  9. 9

    Lamp typeEF002423

    Choose one value

    High voltage halogen lampReplaceable LEDNon-replaceable LEDLow voltage halogen lampOther
  10. 10

    With light sourceEF005905

    Yes or no

    YesNo
  11. 11

    Nominal voltageEF005127

    A range, from and to, in V

  12. 12

    Secondary voltageEF001470

    A number in V

  13. 13

    Max. connection powerEF000232

    A number in W

  14. 14

    Type of attachmentEF000381

    Choose one value

    Electronic transformerElectronic ballastLow-loss ballast inductiveLow-loss ballast compensatedLED operating device voltage-controlledLED operating device current-controlledMagnetic transformerNot required
  15. 15

    Removable accessoriesEF016286

    Yes or no

    YesNo
  16. 16

    Energy efficiency class of the light source according to EU regulation 2019/2015EF016835

    Choose one value

    ABCDEFGNot required
  17. 17

    Rated lifetime L70/B50 at 25 °CEF011870

    A number in h

  18. 18

    Lumen maintenance at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015687

    A number in %

  19. 19

    Failure rate at median useful life of 50,000 hrs at 25 °C ambient (tq)EF015691

    A number in %

  20. 20

    Constant light output (CLO)EF009482

    Yes or no

    YesNo
  21. 21

    Power factorEF025740

    A number

  22. 22

    Type of wiringEF011868

    Choose one value

    Suitable for loop-through wiringLoop-through wiring includedEnding
  23. 23

    Number of polesEF001391

    A number

  24. 24

    Connection typeEF000124

    Choose one value

    CrimpingBlade terminalSolderInsulation displacement connectorScrewed terminalPush-in clampOther
  25. 25

    Wire cross-section to be connectedEF008200

    A range, from and to, in mm²

Codes after each name are ETIM feature codes. Use them, not the names, in product data.