Explosion proof luminaire fixed mounting EC001952
Features 47
- 1
Mounting methodEF000003
Choose one value
Ceiling mountingWall mountingWall-/ceiling mountingMast fasteningWall bracketOther - 2
AlignableEF000441
Yes or no
YesNo - 3
Lamp typeEF002423
Choose one value
Incandescent lampLV halogen lampHV halogen lampMetal halide lampHigh pressure sodium-vapour lampMetal halide/sodium lampLED exchangeableLED not exchangeableFluorescent lampMercury vapour lampOther - 4
With light sourceEF005905
Yes or no
YesNo - 5
Suitable for number of light sourcesEF006436
A number
- 6
Lamp holderEF000048
Choose one value
2G72G102G112G13B15dB22dBA9sE10E14E27 - 7
Housing materialEF001596
Choose one value
AluminiumSteelStainless steelBrassPlasticOther - 8
Cover materialEF004284
Choose one value
Glass, opalGlass, structuredGlass, transparentGlass, matt/satinizedPlastic, opalPlastic, structuredPlastic, transparentPlastic, matt/satinizedOtherWithout cover - 9
Voltage typeEF000187
Choose one value
ACDCAC/DC - 10
Nominal voltageEF005127
A range, from and to, in V
- 11
LED nominal current at constant current (no longer used)EF012150
A range, from and to, in mA
- 12
Type of control gearEF000381
Choose one value
Electronic ballastElectronic transformerLow-loss ballast inductiveLow-loss ballast compensatedLED operating device voltage-controlledLED operating device current-controlledMagnetic transformerNot required - 13
With control gearEF007556
Yes or no
YesNo - 14
Light distributorEF012170
Choose one value
Diffuser lens/optic/panelFocal lensReflectorRefractor lensOtherNone - 15
Beam angleEF008157
Choose one value
< 5° - Parallel beam5-10° - Extreme narrow beam11-20° - Narrow beam21-40° - Medium beam41-80° - Wide beam> 80° - Extreme wide beamOpen beam/diffuse - 16
Energy efficiency class of the built-in lampEF012487
Choose one value
A++, A+, A (LED)Other - 17
Energy efficiency class of the provided exchangeable built-in lampEF012488
Choose one value
A++A+ABCDE - 18
Highest energy efficiency class of the exchangeable lampEF012489
Choose one value
A++A+ABCDE - 19
Lowest energy efficiency class of the exchangeable lampEF012490
Choose one value
A++A+ABCDE - 20
Power supply energy efficiency index (EEI) (no longer used)EF011875
Choose one value
A1 BATA1A2 BATA2A3B1B2COther - 21
Rated lifetime L70/B10 at 25 °C (no longer used)EF011869
A number in h
- 22
Rated lifetime L70/B50 at 25 °CEF011870
A number in h
- 23
Rated life time L80/B10 at 25 °C (no longer used)EF011871
A number in h
- 24
Rated lifetime L80/B50 at 25 °C (no longer used)EF011872
A number in h
- 25
Rated lifetime L90/B10 at 25 °C (no longer used)EF011873
A number in h
- 26
Rated lifetime L90/B50 at 25 °C (no longer used)EF011874
A number in h
- 27
Degree of protection (IP)EF005474
Choose one value
IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30 - 28
Degree of protection (NEMA)EF011959
Choose one value
789Other - 29
Impact strengthEF004293
Choose one value
IK00IK01IK02IK03IK04IK05IK06IK07IK08IK09 - 30
Protection class according to IEC 61140EF000004
Choose one value
IIIIIINone - 31
Suitable for Ex-zone gasEF005728
Choose one value
0, 1, 21, 22None - 32
Suitable for Ex-zone dustEF008404
Choose one value
20, 21, 2221, 2222None - 33
Rated ambient temperature according to IEC 62722-2-1EF012090
A range, from and to, in °C
- 34
Suitable for lamp powerEF000280
A range, from and to, in W
- 35
Max. system powerEF009347
A number in W
- 36
Rated luminous flux according to IEC 62722-2-1 (no longer used)EF009349
A number in lm
- 37
Colour of lightEF009350
Choose one value
BlueRedAmberGreenYellowRGBRGBWWhiteMulti-colouredOther - 38
Colour temperatureEF009346
A range, from and to, in K
- 39
Power factorEF025740
A number
- 40
WidthEF000008
A number in mm
- 41
Height/depthEF001456
A number in mm
- 42
LengthEF001438
A number in mm
- 43
Outer diameterEF000015
A number in mm
- 44
Type of wiringEF011868
Choose one value
Suitable for loop-through wiringLoop-through wiring includedEnding - 45
Number of polesEF001391
A number
- 46
Conductor cross sectionEF000085
A number in mm²
- 47
Connection typeEF000124
Choose one value
CrimpingBlade terminalSolderInsulation displacement connectorScrewed terminalPush-in clampPinching contact (no longer used)Other
Codes after each name are ETIM feature codes. Use them, not the names, in product data.