Three-phase control transformer EC002485

Published Low-voltage switchgear and control gear EG000017

Features 32

  1. 1

    Built as safety transformerEF007235

    Yes or no

    YesNo
  2. 2

    Built as isolating transformerEF007238

    Yes or no

    YesNo
  3. 3

    Built as energy saving transformerEF007005

    Yes or no

    YesNo
  4. 4

    Primary voltage 1EF006125

    A range, from and to, in V

  5. 5

    Primary voltage 2EF006126

    A range, from and to, in V

  6. 6

    Primary voltage 3EF006127

    A range, from and to, in V

  7. 7

    Primary voltage 4EF007410

    A range, from and to, in V

  8. 8

    Primary voltage 5EF007411

    A range, from and to, in V

  9. 9

    Primary voltage 6EF007412

    A range, from and to, in V

  10. 10

    Primary voltage 7EF007413

    A range, from and to, in V

  11. 11

    Primary voltage 8EF007414

    A range, from and to, in V

  12. 12

    Primary voltage 9EF007415

    A range, from and to, in V

  13. 13

    Primary voltage 10EF007409

    A range, from and to, in V

  14. 14

    Secondary voltage 1EF007472

    A range, from and to, in V

  15. 15

    Secondary voltage 2EF007474

    A range, from and to, in V

  16. 16

    Secondary voltage 3EF007475

    A range, from and to, in V

  17. 17

    Secondary voltage 4EF007476

    A range, from and to, in V

  18. 18

    Secondary voltage 5EF007477

    A range, from and to, in V

  19. 19

    Secondary voltage 6EF007478

    A range, from and to, in V

  20. 20

    Secondary voltage 7EF007479

    A range, from and to, in V

  21. 21

    Secondary voltage 8EF007480

    A range, from and to, in V

  22. 22

    Secondary voltage 9EF007481

    A range, from and to, in V

  23. 23

    Secondary voltage 10EF007473

    A range, from and to, in V

  24. 24

    Wiring systemEF002960

    Choose one value

    DYYYYDDDOther
  25. 25

    Rated powerEF007051

    A number in W

  26. 26

    Type of insulation material according to IEC 85EF007299

    Choose one value

    YAEBFHC
  27. 27

    Short-circuit-proofEF007332

    Yes or no

    YesNo
  28. 28

    Relative short-circuit voltageEF007452

    A number in %

  29. 29

    WidthEF000008

    A number in mm

  30. 30

    HeightEF000040

    A number in mm

  31. 31

    DepthEF000049

    A number in mm

  32. 32

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30

Codes after each name are ETIM feature codes. Use them, not the names, in product data.