Light curtain EC002549
Light curtains/ light grids are switching or measuring sensors, consisting of several regularly spaced parallel photoelectric sensors. When an object interrupts only a single beam of the light grid, this is detected by the sensor and triggers a switching operation. In principle, only objects can be reliably detected that are greater than the distance of two beams.
Features 40
- 1
Number of semiconductor outputs with signalling functionEF003945
A number
- 2
Number of contact energized outputs with signalling functionEF003946
A number
- 3
Number of protected semiconductor outputsEF003951
A number
- 4
Number of protected contact energized outputsEF003952
A number
- 5
Fade-out possibleEF003955
Yes or no
YesNo - 6
Type of interface for safety communicationEF003956
Choose one value
AS-Interface Safety at WorkDeviceNet SafetyINTERBUS-SafetyPROFIsafeSafetyBUS pOther - 7
Type of switching output of the OSSDEF003959
Choose one value
NPNNPN/NPNPNPPNP/NPNPNP/PNPRelay contactOther - 8
Type of electric connectionEF003961
Choose one value
Bus capInsulation piercing connectionSpring clamp connectionFlat plug-in connectionCableCable axialCable with connectorCable radialClip connectionClamp - 9
Operation agent-safety classEF003982
Choose one value
Safety class 0Safety class 1Safety class 2Safety class 3 - 10
Width sensorEF007094
A number in mm
- 11
Height of sensorEF007283
A number in mm
- 12
Length of sensorEF007334
A number in mm
- 13
Detection capability for test bodiesEF003991
A number in mm
- 14
Explosion safety category for gasEF003997
Choose one value
ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone - 15
Explosion safety category for dustEF003998
Choose one value
ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone - 16
CascadableEF000507
Yes or no
YesNo - 17
Scope of delivery of the one-way systemEF004032
Choose one value
ReceiverTransmitterTransmitter and receiver - 18
Max. output current at protected outputEF004035
A number in mA
- 19
Ambient temperatureEF002386
A range, from and to, in °C
- 20
With muting functionEF004057
Yes or no
YesNo - 21
Override possibleEF004061
Yes or no
YesNo - 22
Reaction timeEF004094
A number in ms
- 23
Resolution of the light curtainEF006784
A number in mm
- 24
Reduced resolutionEF004095
Yes or no
YesNo - 25
Transmission range of the safety fieldEF004098
A number in m
- 26
Switching voltage of OSSD at state "high"EF004102
A number in V
- 27
Safety field heightEF004103
A number in mm
- 28
Type of safety acc. IEC 61496-1EF004105
Choose one value
1234 - 29
Rated control supply voltage at AC 50 HzEF003978
A range, from and to, in V
- 30
Rated control supply voltage at AC 60 HzEF003979
A range, from and to, in V
- 31
Rated control supply voltage at DCEF003980
A range, from and to, in V
- 32
Voltage typeEF000187
Choose one value
ACAC/DCDCOther - 33
With beam codingEF004114
Yes or no
YesNo - 34
Clock control possibleEF004119
Yes or no
YesNo - 35
With monitoring function downstream switching devicesEF004052
Yes or no
YesNo - 36
Wavelength of the sensorEF004132
A number in nm
- 37
With restart blockageEF004054
Yes or no
YesNo - 38
Suitable for safety functionsEF001597
Yes or no
YesNo - 39
Degree of Protection (IP rating)EF005474
Choose one value
IP00IP20IP44IP54IP64IP65IP66IP67IP68IP69KOther - 40
Degree of protection (NEMA)EF011959
Choose one value
1233R44X66P1213Other
Codes after each name are ETIM feature codes. Use them, not the names, in product data.