Passive sensor-actuator interface EC002585

Distributor for wiring a sensor or Actors in the lowest field level with line.

Published Sensors for automation systems EG020099

Features 34

  1. 1

    Connectable conductor cross sectionEF008200

    A range, from and to, in mm²

  2. 2

    Type of connector for trunk lineEF007494

    Choose one value

    1/2 inch7/8 inch
  3. 3

    Cable screw gland for cable outer diameterEF007302

    A range, from and to, in mm

  4. 4

    Length of the preassembled cableEF007300

    A number in m

  5. 5

    Cable length configurableEF007301

    Yes or no

    YesNo
  6. 6

    Number of sensor-/actuator-slotsEF006939

    A number

  7. 7

    Number of channels per connector slotEF006885

    A number

  8. 8

    Type of branches for sensor-/actuator cablesEF006972

    Choose one value

    M5M8M8-Snap-InM12Insulation displacement connectionOther
  9. 9

    Number of poles sensor/actuator slotsEF007402

    A number

  10. 10

    Rated VoltageEF000228

    A number in V

  11. 11

    Pollution degreeEF006786

    Choose one value

    1234
  12. 12

    Operating voltageEF003983

    A range, from and to, in V

  13. 13

    Max. current carrying capacity per I/O signalEF004037

    A number in A

  14. 14

    Max. current carrying capacity per socketEF004038

    A number in A

  15. 15

    Max. total currentEF004039

    A number in A

  16. 16

    Diameter contact femaleEF007319

    A number in mm

  17. 17

    Material contact bodyEF008248

    Choose one value

    Beryllium copperBronzeCopperBrassNickelPhosphor bronzeOther copper alloysOther not-copper alloys
  18. 18

    Material of contact surfaceEF004020

    Choose one value

    BronzeGoldBrassNickelNickel/goldPalladiumSilverZincTinOtherUntreated
  19. 19

    Material insulation bodyEF007543

    Choose one value

    Polyvinyl Chloride (PVC)Polyamide (PA)PBTLCPOther
  20. 20

    Thread sleeves sensor/actuator slotsEF007277

    Choose one value

    M5M8M12Other
  21. 21

    With LED indicationEF005950

    Yes or no

    YesNo
  22. 22

    With potential separationEF003272

    Yes or no

    YesNo
  23. 23

    Connection for NPN-sensorsEF006817

    Yes or no

    YesNo
  24. 24

    Fix cable version suitable for cable guide chainEF007461

    Yes or no

    YesNo
  25. 25

    Housing MaterialEF001596

    Choose one value

    PlasticPlastic, metallizedStainless SteelAluminium
  26. 26

    Housing ColourEF000136

    Choose one value

    GreyBlackGreenSilverOther
  27. 27

    Operating temperatureEF002393

    A range, from and to, in °C

  28. 28

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  29. 29

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  30. 30

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  31. 31

    WidthEF000008

    A number in mm

  32. 32

    HeightEF000040

    A number in mm

  33. 33

    DepthEF000049

    A number in mm

  34. 34

    Degree of protection (NEMA)EF011959

    Choose one value

    1233R44X66P1213Other

Codes after each name are ETIM feature codes. Use them, not the names, in product data.