Optical fibre sensor / optical fibre amplifier EC002651

Features 35

  1. 1

    Number of semiconductor outputs with signalling functionEF003945

    A number

  2. 2

    Number of contact energized outputs with signalling functionEF003946

    A number

  3. 3

    Analogue output 0 V ... 10 VEF006807

    Yes or no

    YesNo
  4. 4

    Analogue output 0 mA ... 20 mAEF006808

    Yes or no

    YesNo
  5. 5

    Analogue output 4 mA ... 20 mAEF006810

    Yes or no

    YesNo
  6. 6

    Analogue output -10 V ... +10 VEF006809

    Yes or no

    YesNo
  7. 7

    Type of electric connectionEF003961

    Choose one value

    Bus capInsulation piercing connectionSpring clamp connectionFlat plug-in connectionCableCable axialCable with connectorCable radialClip connectionClamp
  8. 8

    Type of switching outputEF003962

    Choose one value

    AS-InterfaceNAMURNPNNPN/NPNOptocouplerPNPPNP/NPNPNP/PNPRelay contactTwo-wire (no longer used)Other
  9. 9

    Type of switch functionEF003963

    Choose one value

    AnticoincidenceBreaker contact (NC)Programmable/configurableNormally open contact (NO)Change-over contact (NO/NC)Forced contact openingOther
  10. 10

    With blanking functionEF003968

    Yes or no

    YesNo
  11. 11

    Operation agent-safety classEF003982

    Choose one value

    Safety class 0Safety class 1Safety class 2Safety class 3Other
  12. 12

    Rated control supply voltage at AC 50 HzEF003978

    A range, from and to, in V

  13. 13

    Rated control supply voltage at AC 60 HzEF003979

    A range, from and to, in V

  14. 14

    Rated control supply voltage at DCEF003980

    A range, from and to, in V

  15. 15

    Voltage typeEF000187

    Choose one value

    ACAC/DCDCOther
  16. 16

    Width amplifierEF007095

    A number in mm

  17. 17

    Height amplifierEF007284

    A number in mm

  18. 18

    Length amplifierEF007335

    A number in mm

  19. 19

    Diameter sensorEF007111

    A number in mm

  20. 20

    IndicationEF000350

    Choose one value

    LEDDigitalBar graphOther
  21. 21

    Setting procedureEF003994

    Choose one value

    Manual adjustmentParameterizationTeach-InAutomaticOther
  22. 22

    Construction type housingEF004008

    Choose one value

    Standard construction (no longer used)ProfileCuboidSpecial construction (no longer used)RodCylinder plainCylinder, screw-thread
  23. 23

    Laser protection classEF004027

    Choose one value

    Class 1Class 2Class 3Other
  24. 24

    No load currentEF004028

    A number in mA

  25. 25

    Type of lightEF004029

    Choose one value

    Blue lightGreen lightInfrared lightLaser diode, infrared lightLaser diode, red lightMulti-coloured LEDPolarized red lightPolarity free red lightWhite lightOther
  26. 26

    Maximum output currentEF001315

    A number in mA

  27. 27

    Nominal operating distanceEF004059

    A number in mm

  28. 28

    Switching frequencyEF003587

    A number in Hz

  29. 29

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  30. 30

    Ambient temperatureEF002386

    A range, from and to, in °C

  31. 31

    Housing MaterialEF001596

    Choose one value

    AluminiumStainless SteelPlasticBrassPTE/FEPZincOther
  32. 32

    Material of cable sheathEF004136

    Choose one value

    Polyurethane (PUR)PUR vulcanizedPolyvinyl Chloride (PVC)SiliconeOther
  33. 33

    Material fibre optics coreEF004137

    Choose one value

    GlassPlasticQuartz glassOther
  34. 34

    With time functionEF003582

    Yes or no

    YesNo
  35. 35

    AWG-numberEF007010

    A number

Codes after each name are ETIM feature codes. Use them, not the names, in product data.