Outer corner for fire-resistant duct EC002658
Features 17
- 1
AngleEF008153
A number in °
- 2
Fire resistance class I - installation duct (no longer used)EF007765
A number
- 3
Fire resistance class E - circuit integrity (no longer used)EF007764
A number
- 4
Height external (no longer used)EF007858
A number in mm
- 5
Width outside (no longer used)EF007707
A number in mm
- 6
Height interior (no longer used)EF007862
A number in mm
- 7
Width inside (no longer used)EF007715
A number in mm
- 8
Useful cross sectionEF005140
A number in mm²
- 9
Number of flame resistant sidesEF007591
Choose one value
234 - 10
Material insulating material (no longer used)EF008124
Choose one value
Mineral fibres (no longer used)Calcium silicateFibre silicateGlass fibre enforced light concreteOther - 11
SheathingEF008096
Choose one value
SteelOtherNone - 12
Surface ProtectionEF000139
Choose one value
UntreatedPre-galvanisedPre-galvanised and coatedCoatedWet varnishedOther - 13
ColourEF000007
Choose one value
AnthraciteGreyWhiteOther - 14
RAL NumberEF000116
A number
- 15
Partitions possibleEF008089
Yes or no
YesNo - 16
With bottom perforation (no longer used)EF007944
Yes or no
YesNo - 17
Cover attachmentEF004586
Choose one value
LooseWith hingeScrew tightOther
Codes after each name are ETIM feature codes. Use them, not the names, in product data.