Outer corner for fire-resistant duct EC002658

A corner piece used to change direction in fire-resistant ducting systems.

Features 19

  1. 1

    AngleEF008153

    A number in °

  2. 2

    Fire resistance class according to EN 13501-2EF025876

    Choose one value

    EI60EI90EI120Other
  3. 3

    Outside heightEF008489

    A number in mm

  4. 4

    Outside widthEF008488

    A number in mm

  5. 5

    Inner heightEF006588

    A number in mm

  6. 6

    Inner widthEF006466

    A number in mm

  7. 7

    Usable cross sectionEF005140

    A number in mm²

  8. 8

    Number of flame durable sidesEF007591

    Choose one value

    234
  9. 9

    Type of insulating materialEF002520

    Choose one value

    Calcium silicateFibre silicateGlass fibre enforced light concreteMineral fibreOther
  10. 10

    SheathingEF008096

    Choose one value

    SteelOtherNone
  11. 11

    Surface protectionEF000139

    Choose one value

    UntreatedCoatedContinuously galvanizedContinuously galvanized and coatedWet varnishedOther
  12. 12

    ColorEF000007

    Choose one value

    AnthraciteGrayWhiteZincOther
  13. 13

    RAL color standardEF000116

    A number

  14. 14

    Partitions possibleEF008089

    Yes or no

    YesNo
  15. 15

    Mounting perforation in bottomEF004545

    Yes or no

    YesNo
  16. 16

    Cover attachmentEF004586

    Choose one value

    LooseScrew tightWith hingeOther
  17. 17

    Suitable for outdoor useEF003532

    Yes or no

    YesNo
  18. 18

    Fire resistance class I - installation duct according to DIN 4102-11EFDE0121

    A number

  19. 19

    Fire resistance class E - circuit integrity according to DIN EN 13501-2EFDE0122

    A number

Codes after each name are ETIM feature codes. Use them, not the names, in product data.