EC002716

Features 67

  1. 1

    Transmission range in a unidirectional systemEF004032

    Choose one value

    TransmitterReceiverTransmitter and receiver
  2. 2

    Max. opening angleEF002642

    A number in °

  3. 3

    Pre failure noticeEF004129

    Yes or no

    YesNo
  4. 4

    With time functionEF003582

    Yes or no

    YesNo
  5. 5

    Rated switching distanceEF008289

    A number in mm

  6. 6

    Max. switching distanceEF007367

    A number in mm

  7. 7

    Maximum output currentEF001315

    A number in mA

  8. 8

    With reflector (no longer used)EF007448

    Yes or no

    YesNo
  9. 9

    Analogue output 0 V ... 10 VEF006807

    Yes or no

    YesNo
  10. 10

    Analogue output 0 mA ... 20 mAEF006808

    Yes or no

    YesNo
  11. 11

    Analogue output 4 mA ... 20 mAEF006810

    Yes or no

    YesNo
  12. 12

    Analogue output -10 V ... +10 VEF006809

    Yes or no

    YesNo
  13. 13

    With other analogue outputEF007485

    Yes or no

    YesNo
  14. 14

    Setting procedureEF003994

    Choose one value

    Manual adjustmentParameterizationOtherTeach-In
  15. 15

    With analog communication interfaceEF007305

    Yes or no

    YesNo
  16. 16

    With AS-Interface communication interfaceEF007306

    Yes or no

    YesNo
  17. 17

    With communication interface CANOpenEF007307

    Yes or no

    YesNo
  18. 18

    With communication interface DeviceNetEF007308

    Yes or no

    YesNo
  19. 19

    With communication interface EthernetEF007309

    Yes or no

    YesNo
  20. 20

    With communication interface INTERBUSEF007310

    Yes or no

    YesNo
  21. 21

    With communication interface PROFIBUSEF007311

    Yes or no

    YesNo
  22. 22

    RS-232 protocol supportEF007312

    Yes or no

    YesNo
  23. 23

    With RS-422 communication interfaceEF007313

    Yes or no

    YesNo
  24. 24

    RS-485 protocol supportEF007314

    Yes or no

    YesNo
  25. 25

    With SSD communication interfaceEF007315

    Yes or no

    YesNo
  26. 26

    With SSI communication interfaceEF007316

    Yes or no

    YesNo
  27. 27

    Number of semiconductor outputs with signalling functionEF003945

    A number

  28. 28

    Number of contact energized outputs with signalling functionEF003946

    A number

  29. 29

    Number of secured semiconductor outputsEF003951

    A number

  30. 30

    Number of protected relay outputsEF003952

    A number

  31. 31

    Type of interface for safety communicationEF003956

    Choose one value

    AS-Interface Safety at WorkDeviceNet SafetyINTERBUS-SafetyPROFIsafeSafetyBUS pOther
  32. 32

    Type of electrical connectionEF003961

    Choose one value

    Bus capInsulation piercing connectionSpring clamp connectionFlat plug-in connectionCableCable axialCable with connectorCable radialClip connectionClamp
  33. 33

    Type of switching outputEF003962

    Choose one value

    NAMURNPNNPN/NPNOptocouplerPNPPNP/NPNPNP/PNPRelay contact (no longer used)Other
  34. 34

    Type of switch functionEF003963

    Choose one value

    AnticoincidenceBreaker contact (NC)Programmable/configurableNormally open contact (NO)Change-over contact (NO/NC)Forced contact openingOther
  35. 35

    Operation agent-safety classEF003982

    Choose one value

    Safety class 0Safety class 1Safety class 2Safety class 3
  36. 36

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  37. 37

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  38. 38

    Housing construction typeEF004008

    Choose one value

    (no longer used)ProfileCuboidCustom design (no longer used)RodCylinder plainCylinder, screw-thread
  39. 39

    Width of sensorEF007094

    A number in mm

  40. 40

    Diameter of sensorEF007111

    A number in mm

  41. 41

    Height of sensorEF007283

    A number in mm

  42. 42

    Length of sensorEF007334

    A number in mm

  43. 43

    Sensing modeEF007503

    Choose one value

    Dark switchingLight-/dark switchingLight switching
  44. 44

    Material of optical surfaceEF004134

    Choose one value

    GlassPlasticOther
  45. 45

    Housing materialEF001596

    Choose one value

    PlasticMetalOther
  46. 46

    Max. output current at protected outputEF004035

    A number in mA

  47. 47

    Min. reflector distanceEF004046

    A number in mm

  48. 48

    Ambient temperatureEF002386

    A range, from and to, in °C

  49. 49

    Response timeEF004094

    A number in ms

  50. 50

    Transmission range of the safety fieldEF004098

    A number in m

  51. 51

    Switching frequencyEF003587

    A number in Hz

  52. 52

    Safety type in accordance with IEC 61496-1EF004105

    Choose one value

    1234
  53. 53

    OSSD switching voltage in "high" stateEF004102

    A number in V

  54. 54

    Rated control supply voltage at AC 50HZEF003978

    A range, from and to, in V

  55. 55

    Rated control supply voltage at AC 60HZEF003979

    A range, from and to, in V

  56. 56

    Rated control supply voltage at DCEF003980

    A range, from and to, in V

  57. 57

    Voltage typeEF000187

    Choose one value

    ACAC/DCDCOther
  58. 58

    With monitoring function downstream switching devicesEF004052

    Yes or no

    YesNo
  59. 59

    Laser safety classEF004027

    Choose one value

    Class 1Class 2Class 3NoneOther
  60. 60

    Sensor wavelengthEF004132

    A number in nm

  61. 61

    Type of lightEF004029

    Choose one value

    Blue lightGreen lightInfrared lightLaser diode, infrared lightLaser diode, red lightMulti-colored LEDPolarized red lightPolarity free red lightWhite lightOther
  62. 62

    spot of lightEF004030

    A number in mm²

  63. 63

    Wire diameter according to AWGEF007010

    A number

  64. 64

    Material of cable sheathEF004136

    Choose one value

    Polyurethane (PUR)PUR vulcanizedPolyvinyl chloride (PVC)SiliconeOther
  65. 65

    With reactivation lockEF004054

    Yes or no

    YesNo
  66. 66

    Suitable for safety functionsEF001597

    Yes or no

    YesNo
  67. 67

    Degree of protection (IP)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30

Codes after each name are ETIM feature codes. Use them, not the names, in product data.