Non-metallic conduit, prewired EC002904
A conduit containing pre-installed electrical wiring for quick installation.
Features 37
- 1
MaterialEF002169
Choose one value
Fiberglass reinforced plastic (GRP)Polycarbonate (PC)/ABSPolycarbonate (PC)Polyethylene (PE)PolyolefinPolypropylene (PP)Polyvinyl chloride (PVC)Other - 2
Halogen freeEF000025
Yes or no
YesNo - 3
Fire retardantEF004471
Yes or no
YesNo - 4
Bending strengthEF005660
Choose one value
FlexiblePliablePliable, self recoveringRigid - 5
Lowest bending radiusEF027079
A number in mm
- 6
Compression strength class according to EN 61386-1EF018127
Choose one value
Extra light (class 1, 125 N)Light (Class 2, 320 N)Medium (class 3, 750 N)Heavy (class 4, 1250 N)Extra heavy (Class 5, 4000 N) - 7
Impact strength class according to EN 61386-1EF018126
Choose one value
Extra light (class 1 / 0.5 Joule)Light (class 2 / 1 Joule)Medium (class 3 / 2 Joule)Heavy (class 4 / 6 Joule)Extra heavy (class 5 / 20 Joule) - 8
Flush-mounted installationEF007517
Yes or no
YesNo - 9
Surface mountedEF003681
Yes or no
YesNo - 10
Suitable for installation on woodEF003687
Yes or no
YesNo - 11
Suitable for hollow wall installationEF003688
Yes or no
YesNo - 12
Suitable for concrete installationEF003682
Yes or no
YesNo - 13
Suitable for machine and systems installationEF003683
Yes or no
YesNo - 14
Suitable for subsurface installation (screed)EF003685
Yes or no
YesNo - 15
Suitable for outdoor useEF003532
Yes or no
YesNo - 16
Suitable for underground installationEF003689
Yes or no
YesNo - 17
Inside diameterEF000065
A number in mm
- 18
Outside diameterEF000015
A number in mm
- 19
Operating temperatureEF002393
A range, from and to, in °C
- 20
Low friction inner coatingEF007856
Yes or no
YesNo - 21
ColorEF000007
Choose one value
BeigeBlackBlueBrownGreenGrayOrangePurpleRedWhite - 22
Number of single-conductor cablesEF009412
A number
- 23
Number of signal / telecom cablesEF009413
A number
- 24
Number of coaxial cablesEF009414
A number
- 25
Number of data cablesEF009415
A number
- 26
With pull wireEF009416
Yes or no
YesNo - 27
Number of low voltage power cablesEF009417
A number
- 28
Number of speaker cablesEF009418
A number
- 29
Number of stranding elementsEF001688
A number
- 30
With protective conductorEF007468
Yes or no
YesNo - 31
With integrated POF cableEF009885
Yes or no
YesNo - 32
Nominal conductor sizeEF007914
A range, from and to, in mm²
- 33
With meter markingEF013724
Yes or no
YesNo - 34
Reaction-to-fire according to EN 13501-6: ClassEF011577
Choose one value
AcaB1caB2caCcaDcaEcaFca - 35
Reaction-to-fire according to EN 13501-6: Smoke productionEF011578
Choose one value
s1s1as1bs2s3 - 36
Reaction-to-fire according to EN 13501-6: Flaming droplets / particlesEF011579
Choose one value
d0d1d2 - 37
Reaction-to-fire according to EN 13501-6: AcidityEF011580
Choose one value
a1a2a3
Codes after each name are ETIM feature codes. Use them, not the names, in product data.