Power cable < 1 kV, for permanent installation EC003248
Features 67
- 1
Conductor materialEF001622
Choose one value
AluminumCopperOther - 2
Conductor surfaceEF010804
Choose one value
BareSilver-platedTinnedOther - 3
Conductors nominal cross sectionEF000060
A number in mm²
- 4
AWG sizeEF011789
Choose one value
00000000001246810 - 5
Nominal cross section conductor (AWG)EF011790
A number in kcmil
- 6
Conductor diameterEF001621
A number in mm
- 7
Conductor class typeEF001632
Choose one value
Class 1 = solidClass 2 = strandedClass 5 = flexibleClass 6 = very flexible - 8
Conductor resistance at 20 °CEF013551
A number in Ohm/km
- 9
Number of conductorsEF001792
A number
- 10
Twisted coresEF012612
Yes or no
YesNo - 11
Conductor insulation materialEF000061
Choose one value
Ethylene tetrafluoroethylene (ETFE)Fluorinated ethylene propylene (FEP)RubberPaperPolyamide (PA)PolyolefinPolytetrafluoroethylene (PTFE)Polyurethane (PUR)Polyvinyl chloride (PVC)Other - 12
Conductor insulation material specificationEF011805
Choose one value
Rubber - Ethylene Propylene Rubber (EPR)Rubber - ethylene-vinyl acetate (EVA)Rubber - Hard grade Ethylene Propylene Rubber (HEPR)Rubber - silicone rubber (SIR)Polyethylene (PE)Crosslinked polyethylene (XLPE)Polypropylene (PP)Other - 13
Core identification according to HD 308 S2EF013766
Yes or no
YesNo - 14
Core identification / coding colorEF013729
Choose one value
BeigeBlueBrownYellowGrayGreenPurpleOrangePinkRed - 15
Phase identificationEF000067
Choose one value
NoneColorNumbersColors and numbersOther - 16
Core ColorEF001703
Choose one value
BeigeBlueBrownColorlessYellowGrayGreenGreen/yellowOrangePink - 17
With protective conductorEF007468
Yes or no
YesNo - 18
Maximum permited conductor temperatureEF003803
A number in °C
- 19
ShieldedEF001791
Yes or no
YesNo - 20
Grounding wireEF001029
Yes or no
YesNo - 21
Protective jacketEF003804
Choose one value
NoneAluminum / polyethylene (AI / PE)Aluminium / polyethylene / polyamide (AI / PE / PA)Rubber - Ethylene Propylene Rubber (EPR)Polyurethane (PUR)Polyvinyl chloride (PVC)Other - 22
Armor typeEF001683
Choose one value
NoneArmouring tapeWireBraidingLap-screenOther - 23
Outer jacket materialEF001625
Choose one value
NoneRubberPolyamide (PA)PolyolefinPolyurethane (PUR)Polyvinyl chloride (PVC)Other - 24
Outer jacket material specificationEF011806
Choose one value
Rubber - chlorinated/chlorosulfonated polyethylene (CPE/CSP)Rubber - Polychloroprene (PCP) (no longer used)Polyethylene (PE)Crosslinked polyethylene (XLPE)Other - 25
Outer jacket colorEF001618
Choose one value
BlackBlueBrownColorlessGreenGrayMulti-coloredOrangePinkPurple - 26
Cable shapeEF013532
Choose one value
RoundFlatOther - 27
Reaction-to-fire according to EN 13501-6: ClassEF011577
Choose one value
AcaB1caB2caCcaDcaEcaFcaNone - 28
Reaction-to-fire according to EN 13501-6: Smoke productionEF011578
Choose one value
s1s1as1bs2s3None - 29
Reaction-to-fire according to EN 13501-6: Flaming droplets / particlesEF011579
Choose one value
d0d1d2None - 30
Reaction-to-fire according to EN 13501-6: AcidityEF011580
Choose one value
a1a2a3None - 31
Halogen free according to EN 60754-1/2 (no longer used)EF009769
Yes or no
YesNo - 32
Flame retardantEF000471
Choose one value
NoAccording to IEC/EN 60332-1-2According to IEC/EN 60332-3-24According to IEC/EN 60332-3-22Other - 33
Low smoke emission (in accordance with EN 61034-2) (no longer used)EF008027
Yes or no
YesNo - 34
Low temperature resistant according to EN 60811-504+505+506EF009771
Yes or no
YesNo - 35
Oil resistant (according to EN 60811-404)EF009770
Yes or no
YesNo - 36
Insulation integrityEF003793
Choose one value
PH 15PH 30PH 60PH 90PH 120FE 90FE 180None - 37
Approximate outside diameterEF003921
A number in mm
- 38
Minimum bend radius, stationary application / permanent installationEF011803
A number in mm
- 39
Nominal equivalent cross section of reinforcementEF013442
A number in mm²
- 40
Permitted cable ambient temperature during assemblyEF001685
A range, from and to, in °C
- 41
Permitted cable ambient temperature after assembly (no vibrations)EF001686
A range, from and to, in °C
- 42
Nominal voltage U0EF001790
A number in V
- 43
Nominal voltage UEF001615
A number in V
- 44
Circuit integrityEF001613
Choose one value
E30E60E90E30 - E60E30 - E90None - 45
Conductor shapeEF001620
Choose one value
RoundSector-shapedOther - 46
Suitable as an installation cableEF013771
Yes or no
YesNo - 47
Certified for marine applicationEF013772
Yes or no
YesNo - 48
Suitable as medium-voltage cableEF013773
Yes or no
YesNo - 49
Suitable as high-voltage cableEF013774
Yes or no
YesNo - 50
Certified as airport lighting cableEF013775
Yes or no
YesNo - 51
WeightEF000167
A number in kg/km
- 52
Circuit integrity according to BS 6387 CWZEFUK0001
Yes or no
YesNo - 53
(no longer used)EFUK0002
Choose one value
PH 15PH 30PH 60PH 90PH 120No - 54
(no longer used)EFUK0003
Yes or no
YesNo - 55
Circuit integrity according to BS 8434-2EFUK0004
Yes or no
YesNo - 56
Circuit integrity according to BS 8491EFUK0005
Choose one value
30 min60 min120 minNo - 57
(no longer used)EFUK0006
Choose one value
30 min60 min90 min120 minNo - 58
(no longer used)EFUK0007
Yes or no
YesNo - 59
(no longer used)EFUK0008
Yes or no
YesNo - 60
(no longer used)EFUK0009
Yes or no
YesNo - 61
(no longer used)EFUK0010
Yes or no
YesNo - 62
(no longer used)EFUK0011
Yes or no
YesNo - 63
(no longer used)EFUK0012
Yes or no
YesNo - 64
(no longer used)EFUK0013
Yes or no
YesNo - 65
(no longer used)EFUK0014
Yes or no
YesNo - 66
(no longer used)EFUK0015
Yes or no
YesNo - 67
(no longer used)EFUK0016
Yes or no
YesNo
Codes after each name are ETIM feature codes. Use them, not the names, in product data.