0 of 0
Power cable < 1 kV, for fixed installations
Electrical cables and wiring. 6092Y; 6181B; 6181XB; 6181XY; 6181Y; 6241B; 6241Y; 6242B; 6242Y; 6243B; 6243Y; 6491B; 6491X; Armoured; BASEC; BS5467; BS6724; Cable; Concentric cable; Double insulated; Energy cable; Energy cable < 1 kV, for permanent installation; Fire Resistant (armoured); Fire Resistant (non-armoured); Flat twin and earth; FP; FP200; HI-TUF; House wiring cable; Installation cable for under plaster; In-wall installation cable; Low smoke zero halogen; Low voltage power cable; LSF Flex 318-B; LSOH; Mains cable; Motorway Cables (TR2153); NYY; Power cable < 1 kV, for fixed installations; Power cable < 1 kV, for permanent installation; PVC Flex 318-Y; Split concentric cable; Steel wire armoured; Street lighting cable; SWA (PVC & LSF); Tails; Twin & Earth; VdS; Wire; Wiring cable
Code:
EC003248
Version:
Group:
Electrical cables and wiring
EG000001Release:
DYNAMIC, ETIM-10.0, ETIM-9.0
01 |
Conductor materialEF001622 - Alphanumeric | ||
02 |
Conductor surfaceEF010804 - Alphanumeric | ||
03 |
Nominal cross sectional area of conductor (mm²)EF000060 - Numeric | ||
04 |
AWG sizeEF011789 - Alphanumeric | ||
05 |
Nominal cross sectional area of conductor (AWG) (kcmil)EF011790 - Numeric | ||
06 |
Conductor Diameter (mm)EF001621 - Numeric | ||
07 |
Conductor categoryEF001632 - Alphanumeric | ||
08 |
Conductor resistance at 20 °C (Ohm/km)EF013551 - Numeric | ||
09 |
Number of coresEF001792 - Numeric | ||
10 |
Twisted coresEF012612 - Logical | ||
11 |
Core insulation materialEF000061 - Alphanumeric | ||
12 |
Specification core insulationEF011805 - Alphanumeric | ||
13 |
Core identification according to HD 308 S2EF013766 - Logical | ||
14 |
Identification/coding colour coreEF013729 - Alphanumeric | ||
15 |
Core identificationEF000067 - Alphanumeric | ||
16 |
Core colourEF001703 - Alphanumeric | ||
17 |
With protective conductorEF007468 - Logical | ||
18 |
Max. conductor temperature (°C)EF003803 - Numeric | ||
19 |
ScreenEF001791 - Logical | ||
20 |
Drain wireEF001029 - Logical | ||
21 |
Lead sheathEF001027 - Logical | ||
22 |
Protective barrierEF003804 - Alphanumeric | ||
23 |
Armouring/reinforcementEF001683 - Alphanumeric | ||
24 |
Material armouringEF013440 - Alphanumeric | ||
25 |
Radial water blocking cableEF011012 - Logical | ||
26 |
Number of pilot/reduced coresEF001697 - Numeric | ||
27 |
Nominal cross sectional area of pilot/reduced conductors (mm²)EF001696 - Numeric | ||
28 |
Nominal cross sectional area of pilot/reduced conductors (AWG)EF011792 - Numeric | ||
29 |
Rodent resistantEF007960 - Logical | ||
30 |
Sheath materialEF001625 - Alphanumeric | ||
31 |
Sheath material specificationEF011806 - Alphanumeric | ||
32 |
Sheath colourEF001618 - Alphanumeric | ||
33 |
Cable geometryEF013532 - Alphanumeric | ||
34 |
Flame retardant according to IEC 60332-1-2EF016492 - Logical | ||
35 |
Flame retardant according to IEC 60332-3-21 (Cat A F/R)EF016493 - Logical | ||
36 |
Flame retardant according to IEC 60332-3-22 (Cat A)EF016494 - Logical | ||
37 |
Flame retardant according to IEC 60332-3-23 (Cat B)EF016495 - Logical | ||
38 |
Flame retardant according to IEC 60332-3-24 (Cat C)EF016496 - Logical | ||
39 |
Flame retardant according to IEC 60332-3-25 (Cat D)EF016497 - Logical | ||
40 |
Low smoke according to IEC 61034-2EF003799 - Logical | ||
41 |
Halogen free according to IEC 60754-1EF016498 - Logical | ||
42 |
Halogen free according to IEC 60754-2EF003792 - Logical | ||
43 |
Halogen free according to IEC 60754-3EF016500 - Logical | ||
44 |
Reaction-to-fire according to EN 13501-6: ClassEF011577 - Alphanumeric | ||
45 |
Reaction-to-fire according to EN 13501-6: Smoke productionEF011578 - Alphanumeric | ||
46 |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particlesEF011579 - Alphanumeric | ||
47 |
Reaction-to-fire according to EN 13501-6: AcidityEF011580 - Alphanumeric | ||
48 |
Circuit integrity according to IEC 60331-1EF016616 - Alphanumeric | ||
49 |
Circuit integrity according to IEC 60331-2EF016617 - Alphanumeric | ||
50 |
Circuit integrity according to IEC 60331-3EF016618 - Alphanumeric | ||
51 |
Circuit integrity according to EN 50200EF016621 - Alphanumeric | ||
52 |
Circuit integrity according to EN 50200 annex EEF016490 - Logical | ||
53 |
Oil resistant according to IEC 60811-404EF009770 - Logical | ||
54 |
Low temperature resistant according to EN 60811-504+505+506EF009771 - Logical | ||
55 |
Cable width approx. (mm)EF003796 - Numeric | ||
56 |
Cable height approx. (mm)EF003797 - Numeric | ||
57 |
Outer diameter approx. (mm)EF003921 - Numeric | ||
58 |
Permitted cable outer temperature during assembling/handling (°C)EF001685 - Range | ||
59 |
Permitted cable outer temperature after assembling without vibration (°C)EF001686 - Range | ||
60 |
Nominal voltage U0 (V)EF001790 - Numeric | ||
61 |
Min. permitted bending radius, stationary application/permanent installation (mm)EF011803 - Numeric | ||
62 |
Suitable for underground installationEF003689 - Logical | ||
63 |
Nominal voltage U (V)EF001615 - Numeric | ||
64 |
Nominal equivalent cross section of reinforcement (mm²)EF013442 - Numeric | ||
65 |
Shape of conductorEF001620 - Alphanumeric | ||
66 |
Suitable as installation cableEF013771 - Logical | ||
67 |
Certified for shipboard applicationEF013772 - Logical | ||
68 |
Certified as airport lighting cableEF013775 - Logical | ||
69 |
Max. tensile strength during installation (kN)EF013801 - Numeric | ||
70 |
Weight (kg/km)EF000167 - Numeric | ||
71 |
Number of strands per conductorEF017357 - Numeric | ||
72 |
Strand diameter (mm)EF017358 - Numeric | ||
73 |
Insulation integrity according to DIN VDE 0472-814EFDE0050 - Alphanumeric | ||
74 |
Circuit integrity according to DIN 4102-12EFDE0051 - Alphanumeric | ||
75 |
Circuit integrity according to BS 6387 CWZEFUK0001 - Logical | ||
76 |
Circuit integrity according to BS 8434-2EFUK0004 - Logical | ||
77 |
Circuit integrity according to BS 8491EFUK0005 - Alphanumeric |
6092Y
6181B
6181XB
6181XY
6181Y
6241B
6241Y
6242B
6242Y
6243B
6243Y
6491B
6491X
Armoured
BASEC
BS5467
BS6724
Cable
Concentric cable
Double insulated
Energy cable
Energy cable < 1 kV, for permanent installation
Fire Resistant (armoured)
Fire Resistant (non-armoured)
Flat twin and earth
FP
FP200
HI-TUF
House wiring cable
Installation cable for under plaster
In-wall installation cable
Low smoke zero halogen
Low voltage power cable
LSF Flex 318-B
LSOH
Mains cable
Motorway Cables (TR2153)
NYY
Power cable < 1 kV, for fixed installations
Power cable < 1 kV, for permanent installation
PVC Flex 318-Y
Split concentric cable
Steel wire armoured
Street lighting cable
SWA (PVC & LSF)
Tails
Twin & Earth
VdS
Wire
Wiring cable