Convector pit complete without grid EC003531

A recessed housing unit installed in the floor that contains a heat exchanger (convector) for space heating. This version is delivered without a cover grid, which must be ordered or installed separately. It allows warm air to rise naturally (convection) or assisted with fans, while remaining flush with the floor for aesthetic integration.

Published Heating systems EG020070

Features 29

  1. 1

    Material pitEF022346

    Choose one value

    SteelPolyesterPolyvinyl chloride (PVC)Other
  2. 2

    Material, grid frameEF024678

    Choose one value

    AluminiumStainless steelSteelPlasticOther
  3. 3

    Material heat exchangerEF020003

    Choose one value

    Steel/steelAluminium/copperSteel/aluminiumOther
  4. 4

    Heat exchanger positionEF024686

    Choose one value

    WallCentre
  5. 5

    Outer lengthEF024679

    A number in mm

  6. 6

    Outer widthEF008488

    A number in mm

  7. 7

    Outer depthEF024681

    A number in mm

  8. 8

    Length grid frameEF010967

    A number in mm

  9. 9

    Width grid frameEF010966

    A number in mm

  10. 10

    Height grid frameEF010968

    A number in mm

  11. 11

    Heat emission according to EN 442 20 °C - 75/65EF024605

    A number in W

  12. 12

    Heat emission according to EN 442 20 °C - 70/40EF012564

    A number in W

  13. 13

    Wall thicknessEF000229

    A number in mm

  14. 14

    N-exponentEF024606

    A number

  15. 15

    With dynamic power boosterEF025275

    Yes or no

    YesNo
  16. 16

    Max. operating pressureEF020449

    A number in bar

  17. 17

    Water contentEF002276

    A number in l

  18. 18

    Number of standard connectionsEF017574

    A number

  19. 19

    Connection 2, left side lowEF016948

    Choose one value

    Inlet flowOutlet flowInlet/outlet flowDouble connection, inlet-outletDouble connection, outlet-inletOther
  20. 20

    Connection 3, left side topEF016949

    Choose one value

    Inlet flowOutlet flowInlet/outlet flowControl valveOther
  21. 21

    Connection 6, right side topEF016952

    Choose one value

    Inlet flowOutlet flowInlet/outlet flowControl valveOther
  22. 22

    Connection 7, right side lowEF016953

    Choose one value

    Inlet flowOutlet flowInlet/outlet flowDouble connection, inlet-outletDouble connection, outlet-inletOther
  23. 23

    With connection pipesEF024690

    Yes or no

    YesNo
  24. 24

    With de-aeration connectionEF020224

    Yes or no

    YesNo
  25. 25

    With de-aeratorEF020079

    Yes or no

    YesNo
  26. 26

    With drain possibility (connection)EF022470

    Yes or no

    YesNo
  27. 27

    With drain valveEF020078

    Yes or no

    YesNo
  28. 28

    Watertight pitEF024687

    Yes or no

    YesNo
  29. 29

    Material division plateEF024691

    Choose one value

    SteelPlasticOther

Codes after each name are ETIM feature codes. Use them, not the names, in product data.