Passive sensor-actuator interface (without cable) EC003558

Published Sensors EG000026

Features 31

  1. 1

    Type of connector for trunk lineEF007494

    Choose one value

    Connector bracketM12M16M23 horizontalM23 verticalOther
  2. 2

    Connectable conductor cross sectionEF008200

    A range, from and to, in mm²

  3. 3

    Cable screw gland for cable outer diameterEF007302

    A range, from and to, in mm

  4. 4

    Number of sensor-/actuator-slotsEF006939

    A number

  5. 5

    Number of channels per connector slotEF006885

    A number

  6. 6

    Type of branches for sensor-/actuator cablesEF006972

    Choose one value

    M5M8M8-Snap-InM12Insulation displacement connectionOther
  7. 7

    Number of poles sensor/actuator slotsEF007402

    A number

  8. 8

    Rated VoltageEF000228

    A number in V

  9. 9

    Pollution degreeEF006786

    Choose one value

    1234
  10. 10

    Operating voltageEF003983

    A range, from and to, in V

  11. 11

    Max. current carrying capacity per I/O signalEF004037

    A number in A

  12. 12

    Max. current carrying capacity per socketEF004038

    A number in A

  13. 13

    Max. total currentEF004039

    A number in A

  14. 14

    Diameter contact femaleEF007319

    A number in mm

  15. 15

    Material contact bodyEF008248

    Choose one value

    Beryllium copperBronzeCopperBrassNickelPhosphor bronzeOther copper alloysOther not-copper alloys
  16. 16

    Material of contact surfaceEF004020

    Choose one value

    BronzeGoldBrassNickelNickel/goldPalladiumZincTinOtherUntreated
  17. 17

    Material insulation bodyEF007543

    Choose one value

    Polyvinyl Chloride (PVC)PA (no longer used)PBTLCPOther
  18. 18

    Thread sleeves sensor/actuator slotsEF007277

    Choose one value

    M5M8M12Other
  19. 19

    With LED indicationEF005950

    Yes or no

    YesNo
  20. 20

    With potential separationEF003272

    Yes or no

    YesNo
  21. 21

    Connection for NPN-sensorsEF006817

    Yes or no

    YesNo
  22. 22

    Fix cable version suitable for cable guide chainEF007461

    Yes or no

    YesNo
  23. 23

    Housing MaterialEF001596

    Choose one value

    PlasticPlastic, metallizedStainless SteelAluminium
  24. 24

    Housing ColourEF000136

    Choose one value

    GreyBlackGreenSilverOther
  25. 25

    Operating temperatureEF002393

    A range, from and to, in °C

  26. 26

    Degree of Protection (IP rating)EF005474

    Choose one value

    IP00IP10IP12IP20IP21IP22IP23IP24IP2XIP30
  27. 27

    Explosion safety category for gasEF003997

    Choose one value

    ATEX gas-ex-protection, Cat. 1GATEX gas-ex-protection, Cat. 2GATEX gas-ex-protection, Cat. 3GOtherNone
  28. 28

    Explosion safety category for dustEF003998

    Choose one value

    ATEX dust-ex-protection, Cat. 1DATEX dust-ex-protection, Cat. 2DATEX dust-ex-protection, Cat. 3DOtherNone
  29. 29

    WidthEF000008

    A number in mm

  30. 30

    HeightEF000040

    A number in mm

  31. 31

    LengthEF001438

    A number in mm

Codes after each name are ETIM feature codes. Use them, not the names, in product data.